Resumen del contenido incluido en la página 1 
                    
                        DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Model:
GBST4336I
GBFL4136I
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with 
and maintenance these instructions for safe 
party responsible for use 
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these 
HOT SURFACES! 
instructions is not followed exactly, a fi re 
Glass and other surfaces are hot during 
or explosion may r
                    
                    Resumen del contenido incluido en la página 2 
                    
                        Read this manual before installing or operating this appliance.  Please retain this owner’s manual for future reference. A. Congratulations Congratulations on selecting a Heatilator gas fi replace, an This owner’s manual should be retained for future  elegant and clean alternative to wood burning fi replaces. reference. We suggest that you keep it with your other  important documents and product manuals. The Heatilator gas fi replace you have selected is designed  to provide the utmost in safety, r
                    
                    Resumen del contenido incluido en la página 3 
                    
                            Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    Resumen del contenido incluido en la página 4 
                    
                        14 Appliance Setup   A. Remove Glass Assembly . . . . . . . . . . . . . . . . . . . . . . . . . 36 B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 36 C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 D. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 E. Lava Rock and Glowing Ember Placement . . . . . . . . . . . . . . 36 F. Install the Log Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . 37
                    
                    Resumen del contenido incluido en la página 5 
                    
                        B. Limited Lifetime Warranty Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet  and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada.   Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.  Warranty Period HHT Manufactured Appliances and Venting Components Covered
                    
                    Resumen del contenido incluido en la página 6 
                    
                        B. Limited Lifetime Warranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass  gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials.  Rust and/or corrosion  on any of the metal surfaces, cast iron components, baffl es, fi repots, doors, or fi rebox area are not covered by this  warranty. • Noise resulting from minor expansion, contraction, or movement of certain p
                    
                    Resumen del contenido incluido en la página 7 
                    
                        Listing and Code Approvals   1 1   A. Appliance Certifi cation C. BTU Specifi cations Maximum Minimum Orifi ce Models MODELS:  GBST4336I, GBFL4136I Input Input Size  (U.S. or Canada) BTU/h BTU/h (DMS) LABORATORY: Underwriters Laboratories, Inc. (UL) US 37,000 26,000 32 (0-2000 FT) TYPE: B-Vent Gas Appliance GBST4336I (NG) GBFL4136I (NG) CANADA STANDARD: ANSI Z21.50-2007 • CSA 2.22-2007 33,300 23,400 33 (2000-4500 FT) US 36,000 27,000 50 (0-2000 FT) This product is listed to ANSI standards for “Vent
                    
                    Resumen del contenido incluido en la página 8 
                    
                        User Guide Operating Instructions   2 2  • Keep remote controls out of reach of children. A. Gas Fireplace Safety • Never leave children alone near a hot fi replace, whether  operating or cooling down. WARNING • Teach children to NEVER touch the fi replace. HOT SURFACES!  Glass and other surfaces are hot during  • Consider not using the fi replace when children will be  operation AND cool down. present. Hot glass will cause burns. Contact your dealer for more information, or visit: www. • DO NOT to
                    
                    Resumen del contenido incluido en la página 9 
                    
                        CLEAR SPACE  3 FT. IN FRONT OF FIREPLACE C. Clear Space F. Remote Controls, Wall Controls and Wall  Switches WARNING! DO NOT place combustible objects in front  of the fi replace or block louvers. High temperatures may  Follow the instructions supplied with the control installed  start a fi re. See Figure 2.2. to operate your fi replace:   Avoid placing candles and other heat-sensitive objects on  For safety: mantel or hearth. Heat may damage these objects. • Install a switch lock or a wall/remote 
                    
                    Resumen del contenido incluido en la página 10 
                    
                        I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries.  When using batteries, unplug the transformer. To prolong battery  life, remove them when using the transformer. FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) WARNING: If you do not follow these instructions exactly, a fi re or explosion  may result causing property damage, personal injury or loss of life. 1. Turn off all electric power to the appliance. •  Immediately call your gas supplie
                    
                    Resumen del contenido incluido en la página 11 
                    
                        J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours  continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.G. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously  on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi re- place break-in. •
                    
                    Resumen del contenido incluido en la página 12 
                    
                        Maintenance and Service   3 3   Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be  replaced prior to operating the fi replace. Frequency: Annually By:  Homeowner When properly maintained, your fi replace will give you  many years of trouble-free service.  We recommend an- Tools needed:  Protective gloves, stable work surface nual service by a qualifi ed service technician.   • Assess condition of screen and replace as necessary.   A. Maintenance Tasks-Homeowner • Ins
                    
                    Resumen del contenido incluido en la página 13 
                    
                        By:  Qualifi ed Service Technician B. Maintenance Tasks-Qualifi ed Service  Technician Tools needed: Protective gloves, vacuum cleaner, whisk  broom, fl ashlight, voltmeter, indexed drill bit set, and a  The following tasks must be performed by a qualifi ed ser- manometer. vice technician. • Verify burner is properly secured and aligned with pilot  Gasket Seal and Glass Assembly Inspection or igniter. Frequency: Annually • Clean off burner top, inspect for plugged ports, corrosion  By:  Qualifi ed Se
                    
                    Resumen del contenido incluido en la página 14 
                    
                        Installer Guide Getting Started   4 4  A. Typical Appliance System NOTICE:  Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not  drawn to scale. Actual product may vary from pictures in manual NOTE:  MUST TERMINATE VERTICALLY NON-COMBUSTIBLE ROOF FLASHING  MAINTAINS MINIMUM CLEARANCE  AROUND PIPE LISTED B-VENT TERMINATION CAP  (SECTION 4D) STORM COLLAR (SECTION  4D) VENT PIPE PENETRATES ROOF PREFERABLY WITHOUT AFFECTING ROOF RAF
                    
                    Resumen del contenido incluido en la página 15 
                    
                        B. Design and Installation Considerations D. Inspect Appliance and Components Heatilator B-type vent gas appliances are designed to op- The following B-vent components are needed for instal- erate with all exhaust gases expelled to the outside of the lation. building, and combustion air pulled from the room. • Fireplace Box Installation MUST comply with local, regional, state and  • Pipe Components national codes and regulations. Consult insurance carrier,  • Firestops local building inspector, 
                    
                    Resumen del contenido incluido en la página 16 
                    
                        • Ensure adequate outdoor air is supplied for combustion  E. Negative Pressure appliances and exhaust equipment. WARNING! Asphyxiation Risk! Negative pressure can  • Ensure furnace and air conditioning return vents are not  cause spillage of combustion fumes and soot. Fireplace  located in the immediate vicinity of the fi replace. needs to draft properly for safety. • Avoid installing the fi replace near doors, walkways or  Draft is the pressure difference needed to vent fi replaces  small isolated
                    
                    Resumen del contenido incluido en la página 17 
                    
                        Framing and Clearances   5 5  NOTICE: Illustrations refl ect typical installations and are  A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams  When selecting a location for the appliance it is important to  are not drawn to scale. Actual installation may vary due to  consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate  clearance around air openings and for service access.  Due to 
                    
                    Resumen del contenido incluido en la página 18 
                    
                        To further prevent drafts, the wall shield and ceiling fi re- B. Constructing the Appliance Chase stops should be caulked with high temperature caulk to  A chase is a vertical box-like structure built to enclose the  seal gaps. Gas line holes and other openings should be  gas appliance and/or its vent system. In cooler climates  caulked with high temp caulk or stuffed with unfaced in- the vent should enclosed inside the chase. sulation. If the appliance is being installed on a cement  NOTICE: Tre
                    
                    Resumen del contenido incluido en la página 19 
                    
                        A E I I H C B G D F MINIMUM FRAMING DIMENSIONS* AB C* D E F G H I Rough Rough Rough Rough GBFL4136I Clearance Combustible Combustible End of Sides of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) Inches ** 38-1/8 23 40 31-5/8 0 0 1/2 36 Millimeters ** 968 584 1016 803 0 0 13 914 * Adjust framing dimensions for interior sheathing (such as sheetrock) **See pipe manufacturer’s installation instructions Figure 5.3 Clearances to Com
                    
                    Resumen del contenido incluido en la página 20 
                    
                        D. Mantel and Wall Projections GBST4336I Mantel Projection WARNING! Risk of Fire! Comply with all minimum clear- TO CEILING ances as specifi ed. Framing or fi nishing material closer than  the minimums listed must be constructed entirely of noncom- MAX. bustible materials (i.e., steel studs, concrete board, etc). Note: All  measurements  18 in inches. GBST4336I Mantel Projection 12 TO CEILING  MAX. 32 11 18  MIN. 12  10 Note: All  11 12 measurements  10  32  9 in inches. 9 6 8 25  5 8 7 19 4 6 3 1