Resumen del contenido incluido en la página 1 
                    
                        Vent-free Fireplace Systems
Models: CFX24, CFX32
Natural Gas or LP, Millivolt
Installation and Operating Instructions
WARNINGS
If the information in this manual is not 
followed exactly, a fire or explosion may 
result causing property damage, personal 
injury or loss of life.
– Do not store or use gasoline or other 
flammable vapors and liquids in the vicinity 
of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
 • Do not try to light any appliance.
 • Do not touch any electrical swit
                    
                    Resumen del contenido incluido en la página 2 
                    
                        CFX Vent Free Fireplace System CONTENTS CFX Series gas log appliances described in this manual feature the  ®   TRIPLE PLAY BURNER SYSTEM with exclusive triple effect technology  producing a full random yellow flame, full depth ember bed and glowing logs.  Important Safety Information ..................................... 3 Electrical Wiring (Milli-volt) ...................................... 18  Connect Optional Wall Switch or Thermostat ....... 18 Product Features and Specifications ..........
                    
                    Resumen del contenido incluido en la página 3 
                    
                        CFX Vent Free Fireplace System IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. IMPORTANT Read these instructions carefully before installing or trying to operate a vent-free gas heater in this firebox.  • Any change to this heater or its controls can be dangerous. • Improper installation or use of the heater can cause serious injury or death  from fire, burns, explosion or carbon monoxide pois
                    
                    Resumen del contenido incluido en la página 4 
                    
                        IMPORTANT SAFETY INFORMATION CFX Vent Free Fireplace System 21. The appliance must be isolated from the gas supply  18. During manufacturing, fabricating and shipping, various  piping system by closing its equipment shutoff valve  components of this appliance are treated with certain  during any pressure testing of the gas supply piping  oils, films or bonding agents. These chemicals are not  system at test pressures equal to or less than 1/2 psig  harmful but may produce annoying smoke and smel
                    
                    Resumen del contenido incluido en la página 5 
                    
                        CFX Vent Free Fireplace System PRODUCT FEATURES & SPECIFICATIONS IGNITION CONTROLS  Piezo ignitor allows ignition of the pilot without the use of  matches or batteries.  Milli-Volt control has four (4) positions:  OFF - All gas to the gas logs is shut off at the  valve.  IGN - Valve position to light/maintain a stand- HI/LO Control Knob ing pilot. On/Off Switch  Control Knob  ON - Valve position to turn ON/OFF log set  Piezo Ignition with remote switch/thermostat. FP2750 Figure 1 -   LOW/HI - Va
                    
                    Resumen del contenido incluido en la página 6 
                    
                        FIREPLACE & SYSTEM DIMENSIONS CFX Vent Free Fireplace System H I E F A B G H C D Figure 2 -  Firebox Dimensions   Ref. CFX24 CFX32 1726  A 11 C\v" (299 mm) 15 Z\v" (387 mm) CFX Barrington dims  B 19 C\v" (502 mm) 26" (660 mm)  C 26 M\," (683 mm) 33" (838 mm)  D 52 Z\x" (1334 mm) 61 >\zn" (1564 mm)  E 44' (1118 mm) 50 C\v" (1289 mm)  F 26 B\," (676 mm) 30 B\," (778 mm)  G 4 Z\x" (114 mm) 4" (102 mm)  H 15" (381 mm) 18 Z\v" (464 mm)  I 11 Z\x" (292 mm) 14 M\," (378 mm)  6 20301726                 
                    
                    Resumen del contenido incluido en la página 7 
                    
                        GETTING STARTED CFX Vent Free Fireplace System GETTING STARTED Do not install the heater: Make sure you have received all parts: • Where curtains, furniture, clothing, or  Check your packing list to verify that all listed parts have  other flammable objects are less than  been received. You should have the following: 42" from the front of the heater. • Unvented gas heater  • In high traffic areas. • Two (2) 90°-angle brackets   • In windy or drafty areas. • Facing  •  Installation/operating inst
                    
                    Resumen del contenido incluido en la página 8 
                    
                        COMBUSTION and VENTILATION AIR CFX Vent Free Fireplace System ADEQUATE COMBUSTION AND VENTILATION AIR This heater shall not be installed in a confined space or unusually tight construction unless  provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, (ANSI Z223.1/NFPA54), defines a confined space as a space  3 whose volume is less than 50 cubic feet per 1,000 BTU per hour (4.8 m per kw) of the aggre- gate input rating of all appliances installed in that
                    
                    Resumen del contenido incluido en la página 9 
                    
                        FIREPLACE INSTALLATION CFX Vent Free Fireplace System Carefully select the best location for installation of your unvented fireplace. The following factors should  be taken into consideration. • Clearance to side wall, ceiling, woodwork and window or other combustibles. Refer to Clearances  and Height Requirements section on Page 10. Minimum clearances to combustibles must be main- tained. • Location must not be affected by drafts caused by kitchen exhaust fans, ceiling fans, return air reg- ist
                    
                    Resumen del contenido incluido en la página 10 
                    
                        CLEARANCES and HEIGHT REQUIREMENTS CFX Vent Free Fireplace System Ensure that minimum clearances shown in Figure 5 are maintained. Left and right clearances are deter- mined when facing the front of the firebox. Follow these instructions carefully to ensure safe installation. Failure to follow these requirements may  create a fire hazard. 1. Sidewall Clearances — The clearance from the inside of the appliance to any combustible adjacent  wall should not be less than 9". Figure 5 2. Ceiling Clear
                    
                    Resumen del contenido incluido en la página 11 
                    
                        GENERAL INSTALLATION INFORMATION CFX Vent Free Fireplace System REMOVE SCREEN Figure 6 1. Remove bottom access door. 2. Remove fireplace screen frame panel by pushing screen frame panel up and out. Do not operate the unit without the screen  frame panel installed. FP2109a Figure 6 -  FP2109a Remove Fireplace Screen Frame Panel NOTE: Fireplace screen must be removed to access log box. remove screen 20301726 11 WARNING                                                                                
                    
                    Resumen del contenido incluido en la página 12 
                    
                        INSTALL MANTEL CFX Vent Free Fireplace System 1. Place base near final position. Make sure you have access to all four (4) sides. 2. Place sides in the approximate location on base. Align back edge of side with back of base.  Secure joining block #1 to bottom of side using two (2) 1 Z\v” screws. Be sure joining block is  flush with bottom of side piece. (Do not attach to base at this time) 3. With the aid of an assistant, and using two (2) joining block #4 and (12) 1 Z\v” screws, secure  header 
                    
                    Resumen del contenido incluido en la página 13 
                    
                        FIREPLACE INSTALLATION CFX Vent Free Fireplace System FIREBOX TO MANTEL INSTALLATION 1. Slide fireplace into mantel. 2. Use the two (2) 'L' brackets provided to secure the fireplace to the mantel. Figure 9 3. When the fireplace is in the proper position, centered in mantel opening, remove the control  panel door and secure fireplace through holes provided in base to the floor of the mantel  using screws provided. Figure 10 'L'  Brackets FP2751 'L' Brackets Figure 9 -  Secure Fireplace to Mantel 
                    
                    Resumen del contenido incluido en la página 14 
                    
                        GENERAL INSTALLATION INFORMATION CFX Vent Free Fireplace System INSTALL OPTIONAL FIREBRICK PANELS 1. Remove optional firebrick panels from packaging. Check to see that you have the following: • Firebrick panels, 3  •  Retainer brackets, 2   •  Black screws, 2  If any part or parts are missing, contact dealer where you bought fireplace.   2. Turn off fireplace and allow to cool. 3. Remove fireplace screen (Refer to Page 11, Figure 6) and logs. 4. Place rear firebrick panel on back wall of firebox
                    
                    Resumen del contenido incluido en la página 15 
                    
                        CONNECT THE GAS CFX Vent Free Fireplace System CHECK GAS TYPE Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not  install fireplace. See dealer where you purchased the fireplace for proper fireplace for your  gas type or conversion kit. INSTALLING GAS PIPING TO FIREPLACE / BURNER SYSTEM LOCATION For propane/LP units, never connect  A qualified installer or service person must  fireplace directly to the propane/LP supply.  connect appliance to gas s
                    
                    Resumen del contenido incluido en la página 16 
                    
                        3" Minimum CONNECT THE GAS CFX Vent Free Fireplace System A manual shutoff valve must be installed  Only persons licensed to work with gas  upstream of the appliance. Union tee  piping may make the necessary gas  and plugged 1/8” NPT pressure tapping  connections to this appliance. point should be installed upstream of the  appliance. Figure 14 NOTE: The gas line connection may be made using 1/2" rigid tubing or an approved flex connector.  Since some municipalities have additional local codes i
                    
                    Resumen del contenido incluido en la página 17 
                    
                        CHECK GAS PRESSURE CFX Vent Free Fireplace System 1. Check gas type. The gas supply must be the same as  stated on the appliance’s rating decal. If the gas supply  is different from the fireplace, STOP! Do not install the  appliance. Contact your dealer immediately. 2. To ease installation, a 24" (610 mm) flex line with  manual shut-off valve has been provided with on this  appliance. Install and attach 1/2" gas line onto shut-off  valve.  3. After completing gas line connection, purge air from 
                    
                    Resumen del contenido incluido en la página 18 
                    
                        ELECTRICAL WIRING (MILLI-VOLT) CFX Vent Free Fireplace System The milli-volt valve is a self-powered combination gas control  that DOES NOT REQUIRE 110V AC TO OPERATE. ODS Pilot On/Off Switch ODS Pilot Wall Switch Millivolt Valve On/Off Switch Spade Terminal TH = 3 Red TP = 1 TP/TH = 2 Red Figure 16 -  Wiring Diagram FP2112 Switch Optional Wall Switch, Thermostat, or Remote Receiver Label all wires prior to disconnection when  servicing controls. Wiring errors can cause  improper and dangerous o
                    
                    Resumen del contenido incluido en la página 19 
                    
                        FIREPLACE SKYTECH REMOTE OFF REMOTE ON ELECTRICAL WIRING (MILLI-VOLT) CFX Vent Free Fireplace System CONNECT REMOTE RECEIVER THESE INSTRUCTIONS SUPERSEDE THE SECTION ENTITLED “HEARTH MOUNT” IN THE  MILLI-VOLT HAND-HELD REMOTE INSTRUCTIONS SUPPLIED WITH THE REMOTE. 1. Remove bottom louver door.   2. Connect the remote connectors located in the unit.   ® 3. Apply Velcro pads with self-adhesive backing to bottom of remote receiver and to floor of compart- ment behind access panel. ® 4. Attach remot
                    
                    Resumen del contenido incluido en la página 20 
                    
                        LOG PLACEMENT CFX Vent Free Fireplace System Before you begin — This unit is supplied with a set of three ceramic fiber logs. Do not handle these  logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After  handling logs, wash your hands gently with soap and water to remove any traces of fibers. The positioning of the logs is critical to Failure to position the parts in accordance  the safe and clean operation of this heater. with these diagrams or failur