Resumen del contenido incluido en la página 1 
                    
                        Installation & Operating manual
The harman TlC 2000 Coal/w ood Stove
R1 1
SAFETY NOTICE
PlEASE rEAd ThIS ENTIrE mANuAl bEFOrE YOu INSTAll ANd uSE YOur NEw rOOm hEATEr.  F AIlurE 
TO FOllOw INSTruCTIONS mAY rESul T IN PrOPErTY dAmAgE, bOdIl Y INjur Y, Or EvEN dEATh.
FOr uSE IN ThE u.S. ANd CANAdA.  dO NOT INSTAll IN A mObIlE hOmE.
IF ThIS STOvE IS NOT Pr OPErl Y INSTAll Ed, A hOuSE FIr E mAY r ESul T.  FOr YOur SAFETY, FOll Ow 
INSTAllATION dIrECTIONS.  
CONTACT lOCAl buIldINg Or FIrE OFFICIAlS A
                    
                    Resumen del contenido incluido en la página 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Resumen del contenido incluido en la página 3 
                    
                        TLC 2000 Coal Stove 3 Sample label - Consult  actual unit label for accurate  information. Solid Fuel Burning Room Heater CAUTION - HOT w HILE IN OPERATION - DO NOT TOUCH - KEEP CHILDREN   Model “TLC 2000” AND CLOTHING AwAY -  CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND  Serial No. 008 INSTRUCTIONS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS A  № de série CONSIDERABLE DISTANCE AwAY FROM THE APPLIANCE. Report #/ Raport # 135-S-28-4 Tested to / Testé à: UL1482-11, UL 737-11, and ULC S627
                    
                    Resumen del contenido incluido en la página 4 
                    
                        TLC 2000 Coal Stove 4 INDEX Specifications   6 Operation    8 Building a Fire   9 Maintenance   13 Installation   15 Chimney System  17 Service Parts List  20 Warranty    23 Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in  property damage, bodily injury, or even death. DO NOT INSTALL IN A MOBILE HOME. SAVE THESE INSTRUCTIONS Harman™ 352 Mountain House Road Halifax, PA 17032 U.S.A. Appliance Certification. model: TLC-200
                    
                    Resumen del contenido incluido en la página 5 
                    
                        TLC 2000 Coal Stove 5  WARNINGS Carbon Monoxide (CO) Awareness Carbon monoxide, referred to as CO, is a color- CO detectors are very sensitive and may   less, odorless gas that is produced during combustion sound an alarm for fumes other than CO or CO  of coal and other fuels. CO fumes are toxic and can from sources other than the stove such as car or  be fatal. lawn mower exhaust. The TLC 2000 is a natural draft system which If the alarm sounds  relies on a properly designed chimney to remove C
                    
                    Resumen del contenido incluido en la página 6 
                    
                        TLC 2000 Coal Stove 6 Specifications - TLC 2000 Weight    375 lbs Flue Size   6 inch Fuel    USA: Pea, Nut, or Stove coal     Cordwood with optional spark screen    Canada: Wood, or coal as above. Wood alone as local            codes allow  Log Length Recommended 16" with 18" Max Heating Capacity  1,900 sq. ft. Blower Size (optional)  135 cfm.  variable speed                                                                                                                                           
                    
                    Resumen del contenido incluido en la página 7 
                    
                        TLC 2000 Coal Stove 7 Top Load Door Clean-out Cover Top Load Opening Top Load  Door Arm Glass  Door Wood Air  Control Grates (2) Coal Bars (3) Side Shield Coal Air Control Removable  Shaker Handle Front Load  Door Latch Ash Door Ash Door Latch                                                                                                                                                                                                                                                                 
                    
                    Resumen del contenido incluido en la página 8 
                    
                        TLC 2000 Coal Stove 8 Operation Fuels for uSA The Stove Coal: Doors Anthracite coal, pea or nut size, is the primary fuel for  Your stove has a large glass-paneled door for loading and  which the TLC2000 is designed. Bituminous coal may also  fire viewing, a separate smaller door for removing ashes and  be burned but the results will vary due to the variation in  a top loading door. To open the glass door, turn the handle  bituminous coal from region to region. clockwise and pull out; to close t
                    
                    Resumen del contenido incluido en la página 9 
                    
                        TLC 2000 Coal Stove 9 Air Controls CAuTION :  THE OPERATION RANGE OF  Coal THE AIR CONTROLS MAy NOT BE ALTERED  The primary air control for coal burning is a knob  FOR ANy REASON. located on the bottom door. Sliding the knob to the left pro- vides less air for a smaller fire. Sliding the knob to the right  provides more air for a larger fire. When burning wood, this  knob should be all the way to the left, closed. Wood The primary air controls for wood burning are located  on each side as shown 
                    
                    Resumen del contenido incluido en la página 10 
                    
                        TLC 2000 Coal Stove 10 Reloading.   Remove  Once you have prepared and maintained a thick charcoal  Cleanout Plate  bed, you should be able to reload the stove, allow some burn- To Burn As A  ing at the maximum air setting, and reset the air control in a  Fireplace Stove few minutes. Select hardwoods if possible, as they are heavier and  contain more heating capacity (BTU’s) per load than do  softwoods. Wood should be split and stored under cover for  “seasoning” - a year is recommended. Your st
                    
                    Resumen del contenido incluido en la página 11 
                    
                        TLC 2000 Coal Stove 11 Building and Maintaining a Coal Fire; Build a wood fire as described but instead of adding larger  wood, limit the size to about 2" in diameter. Add enough 2"  wood that the firebox floor is covered with burning wood. After the wood is burning well for about five minutes, put  the wood air controls in the down position and slide the coal  air control to the right. This makes the primary air flow up  through the grates as is required for coal burning. Next add a layer of co
                    
                    Resumen del contenido incluido en la página 12 
                    
                        TLC 2000 Coal Stove 12 Disposal of Ashes. The TLC 2000 was designed to provide  access to the ash pan without the need for opening the main  door. Wearing heavy protective gloves, open the ash door  and remove the ash pan by pulling it forward by the handle.   Close the ash door before taking the ashes outside for safe  disposal. A good time to empty the ash pan is before loading. This  ensures that the ashes will be cold and safer to handle than  directly after shaking the ashes down or tending
                    
                    Resumen del contenido incluido en la página 13 
                    
                        TLC 2000 Coal Stove 13   Maintenance Like all fine equipment, your TLC 2000 requires some  Glass - Replacement routine maintenance and inspection.  Follow the guidelines  The glass in this unit is a ceramic glass. 5mm X 444mm  in this section to guarantee safe, efficient operation. X 311 mm. available from your Harman dealer. The Stove If the stove’s glass is cracked or broken, you must replace  it before operating your stove. Remove pieces carefully.  Surface Replace glass only with Harman supp
                    
                    Resumen del contenido incluido en la página 14 
                    
                        TLC 2000 Coal Stove 14 Glass - Cleaning Sometimes it will be necessary to clean accumulated ash  Gaskets are located: from the glass surface; allowing this ash to remain on the glass  On the doors to provide airtight closure. for long periods can result in “etching” due to the acidity of  On the lid. the ash. The creosote which accumulates on the glass should  burn off during your hot fires. Handle Never clean the glass while it is hot, and do not use abra- The handle on the front door of your T
                    
                    Resumen del contenido incluido en la página 15 
                    
                        TLC 2000 Coal Stove 15 Installation DO NOT INSTALL IN A SLEEPING ROOM Assembly Blower ( Optional ) Bolt the blower to the bottom rear of the stove with four  Blower Variable  1/4-20 bolts. Tighten the bolts, but do not overtighten. Speed knob The blower speed can be adjusted using the knob that is  built-in to the power cord. When first starting a fire, keep the  blower off. After a good bed of coals is established, you can  run the blower at any speed desired. The power cord for the blower must
                    
                    Resumen del contenido incluido en la página 16 
                    
                        Wall Wall TLC 2000 Coal Stove 16 Floor Protection Parallel versus Corner Installations In all installations, the area under and around the stove  A parallel installation is one in which the back and sides  must be protected from falling ash and live coals. The  of the stove are parallel to the walls behind and to the side  floor protector must be of noncombustible material, and  of the stove. A corner installation is one in which the back  positioned as shown in the accompanying illustration.  o
                    
                    Resumen del contenido incluido en la página 17 
                    
                        TLC 2000 Coal Stove 17 The Chimney System Soot and Creosote - Formation and Need for Removal guidelines in this manual, including size, type, and height to  When wood is burned slowly,  it produces tar and other organic  avoid draft problems. vapors,  which combine with expelled moisture to form soot  When installed and operated according to this manual, the  or creosote. The soot and creosote vapors condense in the  TLC 2000 will produce enough hot gases to keep the chimney  relatively cool chi
                    
                    Resumen del contenido incluido en la página 18 
                    
                        TLC 2000 Coal Stove 18 Non-combustible cover, one  Closest  side only. If two covers are  Combustible Minimum 2" (50mm) used, each must be mounted  Hole with a minimum  Material Clearance to Brick on non-combustible spacers  clearance of  18" (450 mm)  at least 7/8" (21mm) away  between connector and wall. Minimum 12"  from the wall. Liner (300mm) to Brick Fire Clay Thimble Chimney  Connector    1" (25mm) Masonry Chimney Built to     Clearance NFPA 211 Specifications. Minimum 12" (300mm)  to Com
                    
                    Resumen del contenido incluido en la página 19 
                    
                        TLC 2000 Coal Stove 19 dO NOT CONNECT ThIS uNIT TO A ChImNEY  FluE SErvINg ANOThEr APPlIANCE. Existing Masonry Chimneys If you plan on using a pre-existing masonry chimney, have  it thoroughly inspected and cleaned. Any faults which make  the chimney unsafe and unusable must be repaired prior to  use. These can include improper height, structural defects,  blockages, inadequate clearance to combustibles, unsealed  openings into other rooms of the house, signs of creosote or  smoke leakage, a loo
                    
                    Resumen del contenido incluido en la página 20 
                    
                        Service Parts TlC-2000 beginning manufacturing date: N/A  Top load Coal/wood Stove Ending manufacturing date: Active   1-90-08690-1 (black w/door), 1-70-08690-4 (metallic blue), 1-70-08690-5 (honey glo), 1-70-08690-10 (mojave red), 1-70-08690-12 (Forest green), ((Ending manufacturing date: june 2011)--1-70-08690-1 (black) 1-70-08690-2 (Charcoal), 1-70-08690-3 (golden fi re)) 1 2 3 4 5 6 22 7 21 8 20 19 9 10 18 11 17 12 13 14 16 15 Part number list on following page. 06/11