Resumen del contenido incluido en la página 1 
                    
                        COMPACT  L.P.& NATURAL
GAS VENT-FREE STOVE
’
OWNER S OPERATION AND INSTALLATION MANUAL
    WARNING:  If  the  information  in this
manual  is  not  followed  exactly,a  fire  or
explosion  may  result causing  property
damage,  personal injury,  or  loss  of  life.
QN300RYLA      QL300RYLA
Do  not  store  or  use  gasoline  or  other  flammable
QN300RYLA-W  QL300RYLA-W
vapors  and  liquids  in  the  vicinity  of  this  or  any
other  appliance.
WHAT  TO  DO  IF  YOU  SMELL  GAS
 Do  not  try  t
                    
                    Resumen del contenido incluido en la página 2 
                    
                        Table of Contents Safety information warnings--------------------3 Air for conbustion & Ventilation----------------5 Installation-------------------------------------------7 Operation Heater---------------------------- -----11 Cleaning and Maintenance-------------------- 13 Specification----------------------------------------15 Troubleshooting---------------------------------- 16 Parts Breakdown & Parts List-----------------18 Log Placing Instructions------------------------22  2               
                    
                    Resumen del contenido incluido en la página 3 
                    
                        SAFETY  INFORMATION  WARNINGS 1.   This   appliance   is  only  for  use IMPORTANT:   Read   this        WARNING:  Do not allow fans to       with   the  type  of  gas  indicated owner’s  manual  carefully  and blow directly into the heater. Avoid any       on  the  rating  plate. This completely  before trying  to drafts  that alter burner flame patterns.       appliance  is  not  convertible  for assemble, operate, or  service Ceiling fans can create drafts that       use  with  other  gases. 
                    
                    Resumen del contenido incluido en la página 4 
                    
                        SAFETY  INFORMATION LOCAL  CODES Continued 15.  Turn off and unplug heater and let . lnstall and use heater with care. 10.  Before using furniture polish, wax,    cool before servicing. Only a Follow all local codes. In the carpet cleaner, or similar products, qualified service person should absence of local codes, use the turn heater off. If heated, the service and repair heater. latest  edition  of  The National  Fuel vapors from these products may 16.  Operating heater above elevations Gas Co
                    
                    Resumen del contenido incluido en la página 5 
                    
                        AIR  FOR  COMBUSTION  AND  VENTILATION Confined  and  Unconfined  Space Unusually Tight Construction        WARNING:  This heater The  National Fuel Gas Code, ANS The  air  that  leaks  around  doors  and shall not be  installed  in a  confined Z223.1 defines a confined space as a windows  may  provide  enough  fresh space  or unusually   tight  con- space   whose   volume is less than 50 air for  combustion  and  ventilation. struction unless provisions  are cubic feet  per 1,000 Btu per hour H
                    
                    Resumen del contenido incluido en la página 6 
                    
                        3. Add  the  Btu/Hr of all fuel burning appliances in the space.      Vent-free heater                                                       Btu/Hr  Example:      Gas water heater*                                                    Btu/Hr  Gas  water  heater          30,000        Btu/Hr      Gas furnace                                                             Btu/Hr  Vent-free  heater    +      26,000        Btu/Hr      Vented gas heater                                                   Btu/
                    
                    Resumen del contenido incluido en la página 7 
                    
                        INSTALLATION WATER VAPOR:A BY-PRODUCT OF UNVENTED ROOM HEATERS Water vapor is by-product of gas combustion.an unvented room heater prodrces approximately one (1) ounce (30ml) of water for every 1, 000BTU’s (.3kw’s) of gas input per hour. 12 Unvented room heaters are recom- mended as supplemtal heat (a room) rather that a primary heat source(an entire house) in most supplemental heat applications,the water vapor does not create a problem ,in most applications the water vapor enhances the low humi
                    
                    Resumen del contenido incluido en la página 8 
                    
                        CLEARANCES TO COMBUSTIBLES The  installer  must  supply  an  external regulator. (Vent-Free  Operation  Only) The  external  regulator  will reduce  incoming  gas Carefully  follow  the  instructions  below. pressure. You must  reduce  incoming  gas  pressure This  stove  is  a  freestanding  unit to  rating  inches  of  water. If you do not reduce designed  to  set  directly  on  the  floor. incoming gas pressure, heater regulator damage IMPORTANT:  You  must  maintain could  occur. lnstall ext
                    
                    Resumen del contenido incluido en la página 9 
                    
                                 WARNING:   Never   connect Pressure  Testing  Gas          CAUTION:   Avoid  damage to heater   to   private  (non-utility)  gas Supply Piping  System regulator. Hold  gas  regulator  with wells. This  gas  is commonly  known wrench  when  connecting  into  gas as  wellhead  gas. Test  Pressures  In  Excess  Of  1/2 piping  and/or  fittings. PSIG(3.5kPa) 1. Disconnect   heater   with  its          CAUTION:   Use  only  new, black CHECKING  GAS appliance  main gas valve (control iron  or
                    
                    Resumen del contenido incluido en la página 10 
                    
                        2.   Open  gas supply tank valve.          WARNING:   Failure  to  position It is very important to install the logs 3.   Make sure control knob of heater is the  parts  in  accordance  with  these exactly as instructed. Do not modify in the OFF  position. diagrams  or  failure  to  use  only  parts logs. Only use logs supplied with 4.  Check all joints from equipment specifically  approved  with  this  heater heater. shutoff valve to control valve may  result  in  property  damage  or (LP  GAS 
                    
                    Resumen del contenido incluido en la página 11 
                    
                        OPERATING    HEATER FOR   YOUR   SAFETY OPERATING   INSTRUTION OF READ   BEFORE   LIGHTING REMOTE-CONTROLLED BUNER         WARNING:   If  you  do not follow  these  instructions  exactly, a LIGHTING INSTRUCTIONS fire  or  explosion  may  result  causing property  damage, personal injury or loss  of  life. 1.    STOP! Read  the safety information, A.  This  appliance  has  a  pilot  which         page  2. must  be  lighted by control system, 2.  Make sure  equipment  shutoff When lighting  the  p
                    
                    Resumen del contenido incluido en la página 12 
                    
                        (Note: on the auto select  of main OPERATING burner, the main burner  does not HEATER respond  imm-ediately to the set tempera- ture until about one minute later.) Continued b.manual  select of main burner:  Press BURNER button, the flame        is on “MAN” select.  At this selection, the  Fig16 Control   board main burner will keep working no matter what the temperature is set at. If there is OPERATIONS OF a need to shut off the main burner, just BURNER press the “BURNER” button to make the 1
                    
                    Resumen del contenido incluido en la página 13 
                    
                        3.After completion of the above- sensing bulb from the clip, then disco- mentioned two steps, the transmitter nnect the wires to free to control is kept in a state of readiness. If the module from its mounting location  . appliance doesn’t working for a period time, just pull out the plug Note: Do not confuse the mark on from the 110V electrical outlet.  the each wire. 2. Remove two screws and hex nuts, OPERATIONS OF  take out the control module.  When in- Figure  19 -Incorrect  Pilot  Flame K
                    
                    Resumen del contenido incluido en la página 14 
                    
                        We also recommend that you keep Burner CABINET the burner tube and pilot assembly Air  Passageways clean  and  free  of  dust  and  dirt. To  Use     a      vacuum     cleaner    or clean these parts we recommend pressurized air to clean. using compressed air no greater Exterior than 30 PSI. Your local computer  Use a soft cloth dampened  with  a store, hardware store, or home center may carry compressed air in mild soap and water  mixture. Wipe a can. You can use a vacuum the cabinet to remov
                    
                    Resumen del contenido incluido en la página 15 
                    
                        ACCESSORIES FLEXILBE  HOSE  Purchase date Purchase these heater accessories  Usually,    we    will    ask   you   to Flexibe gas hose is used for connect- from your local dealer or Parts      return the defective part to the ing the heater to gas supply. Central. This  part  is  not  currently        factory. available  from  PRO-COM. the flex hose must approved by CSA .   Warranty card. PARTS  NOT  UNDER WARRANTY Contact  authorized  dealers  of  this product  or  Parts  Central. If  they  
                    
                    Resumen del contenido incluido en la página 16 
                    
                        TROUBLESHOOTING      WARNING:Make sure that power       CAUTION: Never use a wire,        WARNING:  Turn off  and let cool is turn off before proceeding.... needle, or similar object  to clean before servicing. Only a  qualified ODS/pilot. This  can  damage  ODS/ service  person  should service and pilot  unit. repair  fireplace. OBSERVED  PROBLEM POSSIBLE CAUSE REMEDY 1. No power to heater 1. Check the electric power No spark when press in ignition button 2. No battery in transmitter or battery
                    
                    Resumen del contenido incluido en la página 17 
                    
                        TROUBLESHOOTING Continued POSSIBLE CAUSE OBSERVED  PROBLEM REMEDY Delayed   ignition  burner 1.   Manifold  pressure  is  too  low 1.   Contact   local  gas company 2.  Clean  burner (see Cleaning  and 2.   Burner orifice clogged        Maintenance, page 13) Burner  backfiring  during  combustion 1.   Damaged burner 1.   Clean  burner  orifice  (see 2.   Gas  regulator  defective Cleaning  and  Maintenance, page 13) 2.   Replace  gas  regulator 1.   Residues  from  manufacturing Slight   smoke  
                    
                    Resumen del contenido incluido en la página 18 
                    
                        ILLUSTRATED PARTS  BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W  18                                                                                                                                                                                                                                                                                                                                                                                                                                        
                    
                    Resumen del contenido incluido en la página 19 
                    
                        PARTS  LIST QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W 19                                                                                                                                                                                                                                                                                                                                                                                                                                                          
                    
                    Resumen del contenido incluido en la página 20 
                    
                        ILLUSTRATED PARTS  BREAKDOWN QL300RYLA QN300RYLA QL300RYLA-W QN300RYLA-W  20