Resumen del contenido incluido en la página 1 
                    
                        R
CLASSIC BAY 1200 PELLET STOVE
Owner’s Manual
Installation and Operation
Beaverton
Tested and
Model: 
Listed by Oregon USA
C US
OMNI- Test Laboratories, Inc.
CB1200
CAUTION
DO NOT DISCARD THIS MANUAL
• Leave this manual with 
• Read, understand and 
• Important operating and 
party responsible for use 
follow these instructions 
maintenance instruc-
and operation.
for safe installation and 
tions included.
operation.
 WARNING
WARNING
HOT! DO NOT TOUCH. 
Please read this entire manual 
SEVERE BU
                    
                    Resumen del contenido incluido en la página 2 
                    
                        R RR CB 1200 Pellet Stove  and Welcome to the Quadra-Fire Family! meticulously fabricated and gold and nickel surfaces are  Hearth & Home Technologies welcomes you to our tradi- hand-finished for lasting beauty and enjoyment.  Our pledge  tion of excellence!  In choosing a Quadra-Fire appliance,  to quality is completed as each model undergoes a quality  you have our assurance of commitment to quality, durabil- control inspection.    From design, to fabrication, to shipping:  ity, and performanc
                    
                    Resumen del contenido incluido en la página 3 
                    
                        R RR CB 1200 Pellet Stove  TABLE OF CONTENTS  E. Starting Your First Fire........................ 2 Section 1: Listing and Code Approvals  F.  Fire Characteristics .............................2  A. Appliance Certifications ......................4  G. Feed Rate Adjustment  .......................2   B. Mobile Home Approved ......................4 H. Ignition Cycles ....................................24  C. Glass Specifications ............................4  I. Frequently Asked Questions.....
                    
                    Resumen del contenido incluido en la página 4 
                    
                        R RR CB 1200 Pellet Stove  Listing and Code Approvals 1 A.  Appliance Certification E.  BTU & Efficiency Specifications Model CB1200 Pellet Stove Emissions Rating 0. 9 grams/hr . Laboratory OMNI Test Laboratories, Inc. *BTU Output 14,000 - 40,000 / hr Report No. 061-S-21-4 Heating Capacity up to 2,500 sq. ft. Type Solid Fuel Room Heater/Pellet Type Hopper Capacity 80 lbs Standard ASTM E1509, ULC S627 and ULC/ Fuel Wood Pellets or Shelled Corn ORD-C1482 Room Heater Pellet Fuel  Shipping Weight 4
                    
                    Resumen del contenido incluido en la página 5 
                    
                        R RR CB 1200 Pellet Stove  Getting Started 2 A. Design, Installation & Location  B. Fire Safety Considerations Maintain the designated clearances to combustibles.  Insu- 1. Appliance Location lation must not touch the chimney.  You must maintain the  designated air space clearance around the chimney.  This  Consideration must be given to safety, convenience, traffic  space around a chimney is necessary to allow natural heat  flow, and the fact that the appliance will need a chimney and  removal 
                    
                    Resumen del contenido incluido en la página 6 
                    
                        R RR CB 1200 Pellet Stove  C.  Tools And Supplies Needed E. Inspect Appliance & Components and  Pre-Use Check List Tools and building supplies normally required  for installation, unless installing into an existing  masonry fireplace: 1. Place the appliance in a location near the  Reciprocating Saw Safety Glasses final installation area and follow the proce- Channel Locks Framing Square dures below: Hammer Electric Drill & Bits (1/4”) 2. Open the appliance and remove all the parts  Phillips Scre
                    
                    Resumen del contenido incluido en la página 7 
                    
                        R RR CB 1200 Pellet Stove  Dimensions and  Clearances 3 A.  Appliance Dimensions 4-5/8 in 8-1/6 in. (205mm) 20- 7/16 in. (519mm) (118mm) 12-/8 in (14mm) 14-1/4 in (62mm) C L 5.0 in 2-1/2 in C (127mm) L (64mm) 25-/4 in. 27-5/8 in. (654mm) (692mm) 28-1/2 in. (724mm) Figure 7.2 - Top View with Top Vent Adapter Figure 7.1 - Top View 28-1/2 in. 25-/4 in. (724mm) (629mm) 1-5/8 in. (80mm) C L 10-/4 in. 8-1/16 in. (27mm) (205mm) 24-/4 in. 26-1/2 in. (629mm) (67mm) Figure 7.3 - Side View Figur
                    
                    Resumen del contenido incluido en la página 8 
                    
                        R RR CB 1200 Pellet Stove  B. Clearances to Combustibles (UL and ULC) Alcove Installation Inches Millimeters Minimum Alcove Height 44 1117 Minimum Alcove Width 40-1/2 1029 A C Maximum Alcove Depth 6 915 Minimum Alcove Side Wall 6 152 Top of Unit to Combustibles 12-1/2 18 B C WARNING Fire Risk. Inches Millimeters Straight Back Against   Comply with all minimum clearances to  Wall combustibles as specified. Back Wall to Appliance 2 51 A Failure to comply may cause house fire. Side Wall to Applia
                    
                    Resumen del contenido incluido en la página 9 
                    
                        R RR CB 1200 Pellet Stove  C. Hearth Pad Requirements (UL and ULC) Alcove Installation Inches Millimeters Minimum Alcove Height 44 1117 Use a non-combustible floor protector, extending beneath  Minimum Alcove Width 40-1/2 1029 appliance and to the front, sides and rear as indicated.   Measure front distance “M” from the surface of the glass  Maximum Alcove Depth 6 915 door. Minimum Alcove Side Wall 6 152 Top of Unit to Combustibles 12-1/2 18 L* K K M Figure 9.1 Inches Millimeters Hearth Pad Re
                    
                    Resumen del contenido incluido en la página 10 
                    
                        R RR CB 1200 Pellet Stove  Vent Information 4 B.  Venting Termination Requirements A.  Chimney and Exhaust Connection 1. Chimney & Connector:  Use  or 4 inch (76-102mm)   diameter type "L" or "PL" venting system.  It can be  CAUTION vented vertically or horizontally. Do not terminate vent in any enclosed or semi-enclosed  2. Mobile Home: Approved for all listed pellet vent.  If using  area such as a carport, garage, attic, crawl space, under a  the  inch (76mm) vertical top vent adapter Kit or
                    
                    Resumen del contenido incluido en la página 11 
                    
                        R RR CB 1200 Pellet Stove  WARNING C. Equivalent Feet of Pipe Improper installation, adjustment, alteration, service or  The table below can help you calculate the equivalent feet  maintenance can cause injury or property damage. Refer  of pipe which is a method used to determine pellet vent size.   to the owner’s information manual provided with this appli- See Figure 11.1 ance. For assistance or additional information consult a  qualified installer, service agency or your dealer. Example of 3 
                    
                    Resumen del contenido incluido en la página 12 
                    
                        R RR CB 1200 Pellet Stove  Venting Systems 5 A. Alcove A C D B Figure 12.1 Inches Millimeters Alcove Installation Minimum Alcove Height 44 1117 A Minimum Alcove Width 40-1/2 1029 B Maximum Alcove Depth 6 915 C Minimum Alcove Side Wall 6 152 D not shown Top of Unit to Combustibles 12-1/2 18 All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR  DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. • Actual installation
                    
                    Resumen del contenido incluido en la página 13 
                    
                        R RR CB 1200 Pellet Stove  B.  Through The Wall NOTE: Horizontal termination cap must be a minimum of 12 inches.  In Canada, where passage through a wall or partition of  (05mm) from the wall.  Approved for mobile home instal- combustible construction is desired, the installation shall  lations.  Must use  or 4 inch (76-102mm) “L” or “PL” listed  conform to CAN/CSA-B65 pellet venting or listed double wall pipe and a Quadra-Fire  outside air kit in mobile homes. 2 in. Straight Out (51mm) Minim
                    
                    Resumen del contenido incluido en la página 14 
                    
                        R RR CB 1200 Pellet Stove  C.  Vertical We recommend a minimum of 60 in.  Rain Cap (1524mm) vertical, however above the eave  is preferred.  Both installations are approved for mobile  home installations.  Must use  or 4 inch (76  Flashing 24 in. (610mm) to 102mm) “L” or “PL” listed pellet venting or  minimum listed double wall pipe and Quadra-Fire out- side  air kit  in mobile homes.  Single wall pipe  is approved for residential installations only. Firestop Class A Chimney Connector Adapter C
                    
                    Resumen del contenido incluido en la página 15 
                    
                        R RR CB 1200 Pellet Stove  WARNING Fire Hazard Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be 6 in. (152mm) UL10 HT. E.  Masonry Fireclay Flue Concrete Cap Liner with Airspace Flashing 1 in. (25mm) Clearance with Firestop 1 in. (25mm) Clearance  in. (76mm) Minimum 6 in. (152mm) Sheathing Minimum Cleanout Cover Airtight Clean-out Door Non-Combustible Hearth Pad Figure 15.1 F.  Alternate Masonry Fireclay Fl
                    
                    Resumen del contenido incluido en la página 16 
                    
                        R RR CB 1200 Pellet Stove  Mobile Home 6 A. Mobile Home Installation CAUTION You must use a Quadra-Fire Outside Air Kit  Maintain structural integrity of mobile home: for installation in a mobile home. •  Floor, wall, ceiling and/or roof. Do NOT cut through: 1. An outside air inlet must be provided for the combustion  • Floor joist, wall, studs or ceiling trusses. air and must remain clear of leaves, debris, ice and/or  • Any supporting material that would affect the structural  snow.  It must b
                    
                    Resumen del contenido incluido en la página 17 
                    
                        R RR CB 1200 Pellet Stove  Appliance Set-Up 7 A. Outside Air Kit Instructions 2.  Floor Installation  a. Remove rear screen and set aside. Included in Kit: 1 piece of 2 inch x  foot flex hose, 2 hose  b. Install cover plate over hole in right rear floor. clamps, 1 collar assembly, termination cap assembly, 1  trim ring, 12 screws.  c. Cut a 2 inch minimum hole in the floor to accommodate  Tools Needed: Phillips head screw driver; wire cutters; flex hose. hole saw or jig saw. d. Attach hose to t
                    
                    Resumen del contenido incluido en la página 18 
                    
                        R RR CB 1200 Pellet Stove  C. Rear Vent and Rear Vent to Top Vent  B. Top Vent Adapter Installation Adapter Installation 3 to 3 inch Top Vent Adapter   3 to 6 inch Top Vent Offset Adapter   Installing the Top Vent Adapter 1. Put a layer of high temperature silicone on the  inch  (76mm) exhaust outlet.  2. Slide the top vent adapter onto the rear exhaust outlet  and adjust the assembly to a vertical position.   . Drill 4 holes with #26 drill bit (provided) into the back of  the appliance using 
                    
                    Resumen del contenido incluido en la página 19 
                    
                        R RR CB 1200 Pellet Stove  E. Brick Clip Installation D. Brick Set Installation 1. Remove the baffle first, follow instructions on page 32. WARNING 2. Slide bottom of left rear brick in first; rotate top edge  Risk of Injury. toward rear of appliance and then rotate outer edge  • Brick may have small wires protruding from  toward rear of appliance, until brick slides into place.  the back of brick. Figure 19.1. . Repeat with right rear brick.  1. After the brick set has been installed, 2 brick 
                    
                    Resumen del contenido incluido en la página 20 
                    
                        R RR CB 1200 Pellet Stove  F. Optional Log Set Placement Instructions G.  Optional Gold or Nickel Grille Assembly CAUTION CAUTION Do not open top all the way back so the weight of the  Logs are FRAGILE.  Use extreme care when handling or  top is supported by the hinges.  It will damage the  cleaning logs. hinges.  It will be necessary to prop the top up with  a supporting brace.  You can use the shipping box as  shown in Figure 1. 1. Place the front log in first as shown in Figure 20.1.  Place