Resumen del contenido incluido en la página 1 
                    
                        Brunel 1A/2CB/3CB
Free Standing Stove
Models : 7008/7008Bl/7008lG/7051/7051Bl/7051lG/7053/7053Bl/7053lG
Instructions for Use,
Installation and servicing
For use in GB & Ie (Great Britain and Republic of Ireland).
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated 
instructions and in some cases the appliance will require modification. Contact Stovax for further information.
IMPoRTA
                    
                    Resumen del contenido incluido en la página 2 
                    
                        CoVeRING THe FolloWING Models:                             7008/7008Bl/7008lG/7051/7051Bl/7051lG/7053/7053Bl/7053lG   APPlIANCe CoMMIssIo NING CHeCKlIsT    3 CoMMIssIoNING 22 UseR INsTRUCTIoNs 4 MAINTeNANCe & seRVICING 23 General Points 4 Annual Service 23 Using the Appliance for the first time 5 Removal of Log Guard 24 Recommended Fuels 5 Removal of Fire Brick 24 Lighting the appliance 6 Removal of Baffle 24 Running the appliance 7 Removal of Riddling Mechanism 24 Burning Tips 8 Fitting a New G
                    
                    Resumen del contenido incluido en la página 3 
                    
                        APPlIANCe CoMMIssIoNING CHeCKlIsT To assist us in any guarantee claim please complete the following information:- dealer appliance was purchased from Name: ................................................................................................................................................................. Address: ...............................................................................................................................................................  ............
                    
                    Resumen del contenido incluido en la página 4 
                    
                        UseR INsTRUCTIoNs 1. GeNeRAl PoINTs Airwash  1.1 Before use of this appliance please read these  Control instructions fully.   Main Door 1.2 All local regulations, including those referring to national  and european standards need to be complied with when  Main Door Catch installing the appliance. Primary Air  1.3 Only use for domestic heating in accordance with these  Control operating instructions.  Cleanburn  Combustion  1.4 You must burn only approved fuels. Do not use with liquid  Control  
                    
                    Resumen del contenido incluido en la página 5 
                    
                        UseR INsTRUCTIoNs 	 •Allow	 fire	 to	 burn	 out	 or	 safely	 dispose	 of	 fuel	 from	 the	 Airwash appliance Closed  Open 	 •	 Check	 for	 chimney	 blockage	 and	 clean	 if	 required  •	 Do	 not	 attempt	 to	 relight	 until	 the	 cause	 of	 the	 emission	 has been identified and corrected  If necessary seek expert advice.  •	All open flued appliances can be affected by temporary  atmospheric conditions which may allow fumes to enter   Primary Air the house. Because of this it is recommended that
                    
                    Resumen del contenido incluido en la página 6 
                    
                        UseR INsTRUCTIoNs 3.2 solid fuel:  4. lIGHTING THe FIRe 	 •	 Burn	 only	 anthracite	 or	 manufactured	 briquette	 smokeless	 fuels listed as suitable for use with closed heating appliances 4.1 For best results:     do not burn bituminous coal, ‘petro-coke’ or other 	 •	 S e t 	 a i r 	 c o n t r o l s , 	 S e e 	 D i a g r a m 	 6 petroleum based fuels as this will invalidate the product  guarantee. Airwash   Fully Open 3.3 Fuel consumption.  As tested at nominal heat output to the requirements 
                    
                    Resumen del contenido incluido en la página 7 
                    
                        UseR INsTRUCTIoNs 	 •	 Rake	 the	 embers	 evenly	 over	 the	 fire	 bed	 and	 open	 the	 Airwash control fully for a few minutes before re-fuelling 5.2 Burn new logs at high output for a few minutes before  adjusting the Airwash control. Refuel little and often for  clean, efficient burning. 5.3 Experience establishes settings to suit personal preferences. Air Inlets 5.4 Do not burn large amounts of fuel with the Airwash control  Log Guard closed for long periods of time. This reduces the glass  
                    
                    Resumen del contenido incluido en la página 8 
                    
                        UseR INsTRUCTIoNs  2) To provide a sufficient amount of draught (suction) in the  5.11 You must burn only anthracite or smokeless fuels  appliance ensuring the fire keeps burning. suitable for use in closed appliances.  Draught is caused by the rising hot air in the chimney when  5.12 do not burn bituminous coal, ‘petro-coke’ or other  the appliance is lit. petroleum based fuels as this invalidates the product  guarantee.  Symptoms of poor performance related to flue draught  include:  do not lo
                    
                    Resumen del contenido incluido en la página 9 
                    
                        UseR INsTRUCTIoNs 7. AsH ReMoVAl 8. oVeR NIGHT BURNING 8.1 It is possible to get the appliance to burn over night. 7.1 All fuels:  In order to do this:   	 •	 Open	 Doors,	 See	 Diagram	 11  •	 De-ash	 prior	 to	 final	 refuelling  •	 Set	 air	 controls	 to	 low	 combustion	 settings  This will blacken the glass over night but it will clear when  operated at high output for a short period.  •	 Use	 smokeless	 fuel	 or	 small,	 thick	 logs	 depending	 on	 fuel	 desired 9. oVeR-FIRING 9.1 Do not o
                    
                    Resumen del contenido incluido en la página 10 
                    
                        UseR INsTRUCTIoNs 13.2 The chimney, any connecting flue pipe and the appliance  11. GeNeRAl CleANING flue ways if incorporated, must be regularly cleaned. 11.1 Allow appliance to cool thoroughly to avoid risk of burns: 13.3 Ensure adequate access to cleaning doors where it is not  	 •	 Clean	 regularly,	 according	 to	 the	 level	 of	 use possible to sweep through the chimney. 	 •	 Give	 attention	 to	 the	 baffle	 system,	 flue	 ways	 and	 removing ash 13.4 If the appliance is believe to have p
                    
                    Resumen del contenido incluido en la página 11 
                    
                        UseR INsTRUCTIoNs 	 •	 Glass	 blackening 15. seAsoNAl Use 	 •	 Thick,	 brown	 and	 sticky	 tar	 oozes	 from	 the	 pipe	 joints 15.1 Clean and service the appliance if it is not used during the   This is caused by burning damp wood and burning your  warmer periods of the year as detailed in the Maintenance  appliance at too low a temperature;  and Servicing section 	 •	 Use	 well	 season ed	 wood	 and	 operate	 the	 appliance	 in	 the ideal temperature range 15.2 Set the air controls 50% open to 
                    
                    Resumen del contenido incluido en la página 12 
                    
                        TeCHNICAl sPeCIFICATIoN BRUNel Model Brunel 1a - 7008/7008BL/7008LG Brunel 2CB - 7051/7051BL/7051LG Brunel 3CB - 7053/7053BL/7053LG Wood kW 4.0 6.0 7.0 Nominal Heat Output Solid Fuel kW 4.0 6.0 7.0 mm Wg 1.25 1.25 1.25 Flue Draught @ Nominal Heat Output All Fuels inch Wg 0.05 0.05 0.05 Wood g/s 3.3 5.5 5.2 Flue Gas Mass Flow Solid Fuel g/s 3.4 5.8 4.5 Wood °C 396 360 442 Flue Gas Temperature @ Spigot/Socket Solid Fuel °C 369 360 442 mm 125 150 150 Flue Outlet Size (Top or Rear Option) inch 5 6 6
                    
                    Resumen del contenido incluido en la página 13 
                    
                        TeCHNICAl sPeCIFICATIoN BRUNel dIMeNsIoNs PR7225 Description Model A B C D E F (dia) G H 7008 Brunel 1a 7008BL 525 385 290 106 430 125 89 95 7008LG 7051 Brunel 2CB 7051BL 640 437 335 115 545 125 122 103 7051LG 7053 Brunel 3CB 7053BL 685 550 330 115 588 150 155 103 7053LG All dimensions in mm. (25.4mm = 1”) 13                                                                                                                                                                                              
                    
                    Resumen del contenido incluido en la página 14 
                    
                        sITe ReQUIReMeNTs 1.5 You must sweep and inspect the flue when the appliance is  1. FlUe oR CHIMNeY installed. 1.6 You must check the flue draught with all windows and  1.1 The flue or chimney system must be in good condition. doors closed and any extraction fans in this or adjoining   It must be inspected by a competent person and passed for  rooms running at maximum speed. (See next section for  use with the appliance before installation additional ventilation requirements)  Products of combus
                    
                    Resumen del contenido incluido en la página 15 
                    
                        sITe ReQUIReMeNTs 1. FlUe oUTleT PosITIoNs Horizontal  Terminal Measurement Flue 150mm  Vertical  max Measurement Adjacent  Building Insulation The vertical measurement is the lowest from either the  point of discharge or 150mm above insulation. Position on Roof Minimum Clearances IMPORTANT: Seek specialist  On ridge or within 600mm 600mm above ridge A advice if installing in a dwelling  with a thatched roof Elsewhere on roof 2300mm horizontally from roof surface and: B a) 1000mm above highest p
                    
                    Resumen del contenido incluido en la página 16 
                    
                        sITe ReQUIReMeNTs WAlls NexT To HeARTHs Solid, non-combustible  Thickness W material e.g. masonry  or concrete H C 150mm minimum 150mm C minimum PR7227 Position of Appliance & Hearth in relation to walls Requirement for the walls distance of hearth from wall distance of Appliance to wall Min thickness of Wall Min height of wall  'C' 'W' 'H' 0mm 0mm - 50mm 200mm Height of appliance + 300mm Or 1200mm from the hearth (take largest  0mm 51mm - 300mm 75mm dimension) 0 - 150mm 150mm + 75mm 1200mm 150m
                    
                    Resumen del contenido incluido en la página 17 
                    
                        Brunel 3CB Brunel 2CB Brunel 1a PRe-INsTAllATIoN CHeCKs 1. FlUe Model Brunel 1a - 7008/7008BL/7008LG Brunel 2CB - 7051/7051BL/7051LG Brunel 3CB - 7053/7053BL/7053LG mm 150 150 150 Without Liner System Round (diameter) inch 6 6 6 mm 135 135 135 Without Liner System (square) minimum  Flue/Chimney size dimension 1 1 1 inch 5 / 5 / 5 / 2 2 2 † With Liner or Factory made System  mm 150 150 150 (diameter)  † inch 6 6 6 installed in accordance with manufacturers instructions m 4 4 4 Flue/Chimney Minimu
                    
                    Resumen del contenido incluido en la página 18 
                    
                        PRe-INsTAllATIoN CHeCKs 3. VeNTIlATIoN 3.1 This appliance requires ventilation to supply combustion air.  Any room containing the appliance must have a permanent  2  air vent opening with a total free area of at least 550mm per kW of appliance rated output above 5kW. 3.2 Increase air supply provisions where a room contains  multiple appliances. 3.3 If vents open into adjoining rooms or spaces there must be  an air vent of at least the same size direct to the outside. 3.4 Permanent air vents shou
                    
                    Resumen del contenido incluido en la página 19 
                    
                        INsTAllATIoN INsTRUCTIoNs  1.1 Take care when installing the appliance. Careless  leGAl ReQUIReMeNTs handling and use of tools can damage the finish and/or  area. Before installation of this product please read these  	 •	Assemble the appliance by attaching the legs to the  instructions fully. base of the appliance, see picture 1 It is very important to understand the requirements of the national  Building Regulations* and standards**, along with any local  regulations and working practices that
                    
                    Resumen del contenido incluido en la página 20 
                    
                        INsTAllATIoN INsTRUCTIoNs   The Flue must be installed in accordance with  manufacturers instructions. Seal Collar with Fire Cement Self Tapping Screw PR8009 Tee Size Stovax Part No.  The Flue must be installed in accordance with  manufacturers instructions. 5" 4516 6" (4616)* Flue Pipe 915mm (3ft) Size Stovax Part No. *5" 4502 6" 4602 Cap Self tappping  screw at rear PR7228 Seal flue collar  To chimney connection as detailed in with Fire Cement building regulation Elbow with access cover PR7230