                        INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
The Studio Series Direct Vent Zero 
LUXURY DIRECT VENT 
Clearance Gas Fireplace Heater
GAS FIREPLACE HEATER
MODEL SERIES
MILLIVOLT STANDING PILOT
DVX36DP31(N,P)-1
DVX42DP31(N,P)-1
INTERMITTENT PILOT
DVX36DP71(N,P)-1
DVX42DP71(N,P)-1
REMOTE RF
DVX36DP91(N,P)-1
DVX42DP91(N,P)-1
GAS-FIRED
Installer: Leave this manual with the appli-
ance.
UL FILE NO. MH30033
Consumer: Retain this manual for future refer-
ence.
WARNING: If the information in these instruc
                    
                    Resumen del contenido incluido en la página 2 
                    
                        TABLE OF CONTENTS Section                                                                                                                                                      Page Important Safety Information .....................................................................................................................................3 Safety Information for Users of LP Gas .....................................................................................................................
                    
                    Resumen del contenido incluido en la página 3 
                    
                        IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED • If this appliance is installed directly on carpeting, tile • Adequate accessibility clearances for servicing and proper  or other combustible material other than wood flooring operation. the appliance shall be installed on a metal or wood panel  • This appliance must not share or be connected to a flue  e
                    
                    Resumen del contenido incluido en la página 4 
                    
                        SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires by point with the members of your household. Someday when  and explosions. In its natural state, propane is odorless and there may not be a minute to lose, everyone’s safety will depend  colorless. You may not know all the following safety precau- on knowing exactly what to do. If, after reading the following  tions which can protect both you and your family from an information, you feel you still ne
                    
                    Resumen del contenido incluido en la página 5 
                    
                        REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed 3. SIGNAGE. A metal or plastic identification plate shall be  in every dwelling, building or structure used in whole or in part permanently mounted to the exterior of the building at a  for residential purposes, including those owned or operated by the minimum height of eight (8) feet above grade directly in line  Commonwealth and where the side wall exhaust vent termination with the exhaust vent 
                    
                    Resumen del contenido incluido en la página 6 
                    
                        INTRODUCTION Instructions to Installer Any alteration of the original design, installed other than as  1. Installer must leave instruction manual with owner after shown in these instructions or use with a type of gas not shown on  installation. the rating plate is the responsibility of the person and company  2. Installer must have owner fill out and mail warranty card supplied making the change. with the fireplace. Important 3. Installer should show owner how to start and operate the All corres
                    
                    Resumen del contenido incluido en la página 7 
                    
                        SPECIFICATIONS DVX36 NAT DVX36 LP DVX42 NAT DVX42 LP Input Btu/hr Maximum 35,000 30,000 37,500 35,000          Btu/hr Minimum 24,000 21,000 26,000 24,000 KWH (Maximum) 10.3 8.8 11.0 10.3            (Minimum) 7.2 6.2 7.6 7.2 Orifice #32 (P-211) 1.65 mm (P-250) #31 (P-209) #50 (P-245) Air Shutter Opening 1/4"(6.4 mm) FULL OPEN 1/4" (6.4 mm) FULL OPEN Height without standoff 34 3/4 (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm) 34 3/4" (3.2 mm) Width 39 3/8" (1,000 mm) 39 3/8" (1,000 mm) 43 3/8" (1,101
                    
                    Resumen del contenido incluido en la página 8 
                    
                        CLEARANCES Mantel Chart (Figure 3) Clearance to Combustibles Back 0" (0 mm) 12”(305mm) 10”(254mm) Side 0" (0 mm) Floor 0" (0 mm) MANTEL Top Stand-off 0" (0 mm) COMBUSTIBLETRIMAND 8” Top Framing Edge 6" (152 mm) MANTELSALLOWEDIN SHADEDAREA 6” 19” SEEMANTLECHARTFOR 41/2” MAXIMUMMANTLEDEPTH 33/4” 3” 183/4” 21/4” 2”x4”HEADER 11/2” 17” 16” 3/4” 15” STANDOFF 14” 6”(152mm)HEIGHT 13” 12” ABOVETOPOF 11” SEEMANTLECHART 10” FIREPLACE FORMINIMUMHEIGHT OFMANTLEABOVEUNIT TOPEDGEOFFIREPLACE FINISHEDWALL (COMBU
                    
                    Resumen del contenido incluido en la página 9 
                    
                        GAS SUPPLY Installing a New Main Gas Cock The gas pipeline can be brought in through the right or left side of  the appliance. Consult the current National Fuel Gas Code, ANSI  Each appliance should have its own manual gas cock. Z223.1 CAN/CGA-B149 (.1 or .2) installation code. A manual main gas cock should be located in the vicinity of the  Recommended Gas Pipe Diameter unit. Where none exists, or where its size or location is not ad- Pipe Length Schedule 40 Pipe Tubing, Type L equate, contact 
                    
                    Resumen del contenido incluido en la página 10 
                    
                        INSTALLATION Framing and Finishing  VENT PIPE 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to  allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable nailing flange. Preset  depth to suit facing material (adjustable to 3/8", 1/2" or 3/4" depths).  Note: Fireplace must mount flush to facing material. If facing  material requires more depth than 3/4" mark and drill two  (2) 1/8" holes into fireplace
                    
                    Resumen del contenido incluido en la página 11 
                    
                        INSTALLATION (continued) DVX36 DVX42 "A" 40 7/8" 40 7/8" NAIL OR OTHER SUIT ABLE F ASTENER "B" 40 3/8" 43 3/8" Figure 10 "C" 19 7/8" 19 7/8" Framing (Figure 11) Figure 11 Fireplace framing can be built before or after the fireplace is set in  place. Framing should be positioned to accommodate wall covering  Attention: If a base is not used and the appliance is installed directly  and fireplace facing material. The fireplace framing should be  on tile or other combustible material other than wood
                    
                    Resumen del contenido incluido en la página 12 
                    
                        Flush Wall Installation FINISHED WALL Attention: Cold climate installation recommendation:  When installing this unit against a non-insulated exterior  6”OFNON-COMBUSTIBLEMATERIAL wall, it is recommended that the outer walls be insulated to  NON-COMBUSTIBLEMATERIAL conform to applicable insulation codes. (INSTALLATIONISOPTIONAL Vent Runs (Figures 14, 15, and 16) In planning the installation for the fireplace, it is necessary to install  JOINTBETWEENFINISHED WALL ANDUNITSEALED certain components 
                    
                    Resumen del contenido incluido en la página 13 
                    
                        INSTALLATION (continued) VERTICAL, 90° ELBOW TO  CORNER INSTALLATION VERTICAL, 90° ELBOW TO  HORIZONTAL OUT THE WALL HORIZONTAL OUT THE WALL WALLFIRESTOP/ “A” 90ºELBOW “A” THIMBLE PIPE LENGTH “B” 6”(152mm) MINIMUM “C” VENT CAP 9”(229mm) “D” MINIMUM VENTCAP WALLFIRESTOP/ THIMBLE “C” Dim. DVX36 DVX42 “B” 45 3/8" (1152 mm) 49 5/8" (1260 mm) A "A" "B" "C" 32 1/8" (816 mm) 35 1/8" (892 mm) B 6"(152 mm) 11 1/4"(286 mm) to 4 3/4"(121 mm) to 13 3/8" (34  mm) 15 1/2" (39  mm) C 12 3/4"(324 mm) 6 1/4"(159
                    
                    Resumen del contenido incluido en la página 14 
                    
                        VENTING FIREPLACE - TOP Venting Graph (Dimensions in Feet) To Use the Vent Graph (Figure 17) 1. Determine the height of the center of the horizontal vent  pipe. Using this dimension on the Sidewall Vent Graph, TOP EXIT - VERTICAL AND HORIZONT AL TERMINA TION (DIMENSIONS IN FEET) locate the point it intersects with the slanted graph  line. 2. From the point of this intersection, draw a vertical line  to the bottom of the graph. 3. Select the indicated dimension, and position the unit in  accordan
                    
                    Resumen del contenido incluido en la página 15 
                    
                        VENTING FIREPLACE - TOP (continued) Installation of Flue Heat Shield HOLESFOR42”MODELS 1. Remove flue insulation. TAB 2. Remove (2) screws on outside of inlet vent adapter.   See Figure 18. 3. Lift top shield placing flue heat shield around flue. 4. Replace (2) screws on outside of inlet vent adapter.   See Figure 19. 5. Bend tab at top front of flue heat shield if necessary to maintain  air gap between flue pipe and flue heat shield. 6. Replace flue insulation. HOLESFOR36”MODELS Figure 18 NOTE:
                    
                    Resumen del contenido incluido en la página 16 
                    
                        VENTING FIREPLACE - TOP (continued) Below Grade Installation When it is not possible to meet the required vent terminal clearances  of 12" (305mm) above grade level, a snorkel kit is recommended. It  allows installation depth down to 7" (178 mm) below grade level.  The 7" (178 mm) is measured from the center of the horizontal  vent pipe as it penetrates through the wall. Ensure the sidewall venting clearances are observed. If venting  system is installed below ground, we recommend a window well 
                    
                    Resumen del contenido incluido en la página 17 
                    
                        10” (254mm) VENTCAP C 12” B (305mm) V H SEECHARTFOR PERMISSIBLE “H”AND“V” C DIMENSIONS 9”(229mm)minimum B TOSIDEWALL A CENTEROFELBOW STRAIGHTOUT (MINIMUM) Figure 24 3’ (914mm) Figure 23 MINIMUM  HOLE LOCATION DIMENSIONS FOR  THROUGH THE WALL HORIZONTAL INSTALLATIONS  WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE FIREPLACE HARD ELBOW DIMENSIONS SERIES "A" "B" "C" DVX36FP 43-1/2" 5"  7"  (1105 mm) (127 mm) (178 mm) MAXIMUMHORIZONTAL RUNWITHNOVERTICAL DVX42FP 43-1/2" 5"  7" RISEAND90°ELBOW (1105 mm) (1
                    
                    Resumen del contenido incluido en la página 18 
                    
                        EXAMPLES - TOP VENT RUN Example H2 3ft, H3 1ft = 4ft (90° + 90° + 90°) = 6ft V1 = 21ft H = 10ft V = 21ft Figure 27 Figure 26 Example H1 = 2ft V1 = 20ft H = 2ft V = 20ft Figure 28 Page 18 25613-0-0309                                                                                                                                                                                                                                                                                                             
                    
                    Resumen del contenido incluido en la página 19 
                    
                        DVVK-4FV DIRECT VENT TERMINATION KIT Installation Instructions This termination kit can only be used with Empire Comfort Systems direct vent fireplaces listed for use with  DVVK-4FV Vertical Flex Vent Kit. Please review the instructions packaged with your fireplace and verify the  fireplace model number. Check that this flex vent system is listed for use with your fireplace model prior to  starting the installation. This vent kit may be installed as an OEM installation in a manufactured home (US
                    
                    Resumen del contenido incluido en la página 20 
                    
                        DVVK-4FV DIRECT VENT TERMINATION KIT (cont.) PRE-INSTALLATION INFORMATION: Items Required For Installation: Tools Building Supplies Phillips Screwdriver Framing Materials Hammer Wall Finishing Materials Saw and/or saber saw Caulking Material (Noncombustible) Level Support Strap supplies Measuring Tape Electric Drill and Bits Pliers Square Tin Snips Before You Start: Plan your installation. Read these instructions and the fireplace installation manual before installing unit and vent system. Set u