Resumen del contenido incluido en la página 1 
                    
                         
Operation Manual 
 
 
 
 
 
 
 
 
 
NVS 14 Series  
NIGHT VISION MONOCULAR 
NVS 14-3XT, NVS 14-3GCS, NVS 14-3AG, NVS 14-3AGBW 
105 Sparks Ave., Toronto, ON, M2H 2S5, Canada 
                                                                                                                                                                                                                                                                                                                                    
                    
                    Resumen del contenido incluido en la página 2 
                    
                                  This page was intentionally left blank               ii                                                                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    Resumen del contenido incluido en la página 3 
                    
                        IMPORTANT INFORMATION  Read prior to activation.  You have purchased a sophisticated electronic device.  To  operate it properly, please read this manual carefully.  Ignoring the operation procedures described in this manual  will void your warranty.     NEVER disassemble the Unit. This device contains a source  of high voltage, which may be hazardous to your health.   NEVER open the objective lens of an active Unit in bright  light, including daylight. In the daytime the objective lens  must 
                    
                    Resumen del contenido incluido en la página 4 
                    
                        Precautions  All NVS 14 series devices are sophisticated electro-optical  instruments. They should be handled with due care:   Each Unit contains fragile components. Avoid hard impacts,  dust, moisture and abrupt changes of temperature.   Do not touch the optical surfaces other than for cleaning with  an appropriate lens cleaning kit. Doing so may damage the  anti-reflective coating.   Clean optical surfaces with professional lens cleaning  supplies.   Use only a soft clean cloth to clean th
                    
                    Resumen del contenido incluido en la página 5 
                    
                        TABLE OF CONTENTS    1.  OVERVIEW .................................................................... 3  2.  STANDARD DELIVERY SET ....................................... 5  2.1  Optional accessories .............................................. 5  3.  SPECIFICATIONS .......................................................... 6  4.  UNIT DESIGN................................................................. 8  5.  OPERATION INSTRUCTIONS ..................................... 9  Installing batte
                    
                    Resumen del contenido incluido en la página 6 
                    
                        6.  TROUBLESHOOTING ................................................. 21  No green (or black and white) image visible .................. 21  Image is unclear ............................................................. 21  Image flashes .................................................................. 21  Condensation accumulates on Unit ................................ 21  Visibility decreased or disappeared ................................ 22  7.  WARRANTY ...................................
                    
                    Resumen del contenido incluido en la página 7 
                    
                        1. OVERVIEW  Your NVS 14 series device (the “Unit”) is an optoelectronic  monocular, intended for observation of objects and orientation at  night or under dark conditions.  The Unit is equipped with a  Generation 3 (“Gen 3”) image intensifier tube (“IIT”), which  amplifies low light, such as moonlight, starlight or man-made  light. The Unit is waterproof to the depth of 1 meter for 30  minutes (with the exception of NVS 14-3GCS which is  waterproof to 20 meters for 30 minutes).  3x, 4x and 8x a
                    
                    Resumen del contenido incluido en la página 8 
                    
                        Features   Flip-up mechanism provides for unobstructed vision when  the Unit is mounted on headgear or helmet;   Built-in infrared illuminator enables observation in total  darkness (i.e. basement, cave or dark room);   Optional NVS H Mount (helmet mount) allows for  effective combat operations;   Optional weapon mount converts Unit to a night vision  weapon sight that can be used alone or in conjunction  with other daytime weapon sights;   Soft rubber eyecup makes viewing comfortable;   U
                    
                    Resumen del contenido incluido en la página 9 
                    
                        2. STANDARD DELIVERY SET   QUANTITY  NVS 14 Series Unit 1  Head Harness 1  NVS Arm Mount 1  Objective Lens Cap 1  Operation Manual 1  Lens Cleaning Kit 1  AA battery 1  2.1 Optional accessories  US-style clip mount NVS Bridge   Demist shield Hard case  Sacrificial window Lens brush  3x add-on lens Camera / video adapter  5x add-on lens NVS H Mount  Weapon mount NVS Coupler    Exact Delivery Set is subject to specific contract terms.        5                                                       
                    
                    Resumen del contenido incluido en la página 10 
                    
                        3. SPECIFICATIONS   Model 3XT 3GCS 3AG 3AGBW  IIT Generation Gen 3  Photocathode Material Gallium Arsenide (GaAs)  Black &  Image Colour Green  White  Photocathode Diameter 17.5mm  1 1800 µA/lm  Minimum Photocathode  2 Sensitivity  190 mA/W  3 40,000 – 70,000 fL/fc  Luminous Gain  4 10,000 – 20,000 fL/fc  Auto-gating X   5 Minimum Resolution 64 lp/mm  6 Minimum Signal to Noise 24  Bright Source Protection   Automatic Brightness Control   Auto-gating X  Manual Gain Control   Manual Gain Adj
                    
                    Resumen del contenido incluido en la página 11 
                    
                        1x 3V CR-123 Lithium battery  Power supply OR  1x 1.5 V AA Alkaline or lithium battery  Maximum Current  25 mA  Consumption  Voltage 2.8 0.8  20 hours with I/R  Battery life  40 hours without I/R  Dimensions 118x48x69mm  Weight 300g  Operating Temperature Range -50 to +55 °C  MTBF 10,000 hours  @2.5 lp/mm 92%  @7.5 lp/mm 80%  Modulation Transfer Function  @15.0 lp/mm 61%  @25.0 lp/mm 38%  Spot Size  Zone 1 Zone 2 Zone 3  (inches)  0.012 ~  0 0 0  0.015  0.009 ~  Black Spots Allowed per Zone 0 0
                    
                    Resumen del contenido incluido en la página 12 
                    
                        4. UNIT DESIGN    5 4 8  9 3  6 7 2  1 FIGURE 1    1. On/Off/IR/Auto switch 6. Battery compartment cover   and battery selection bushing   2. Objective lens cap  7. Battery compartment  3. Objective lens  8. Dovetail platform  4. Eyepiece with eyecup  9. Manual gain adjustment knob  5. Housing  8                                                                                                                                                                                                           
                    
                    Resumen del contenido incluido en la página 13 
                    
                          5. OPERATION INSTRUCTIONS  Installing battery  Unit is supplied without a battery installed.   Prior to installing the battery, make sure the On/Off/IR/Auto  switch (1, Fig.1) is in the OFF position and the objective lens  cap is on.  The Unit can operate on either a single AA or CR-123 lithium  battery. Lithium batteries hold a charge longer than conventional  batteries and provide better performance at low temperatures.  To install a battery remove the battery compartment cover (6,  Fig.1) b
                    
                    Resumen del contenido incluido en la página 14 
                    
                        the screen is not lit ensure the batteries installed are charged  and the polarity is correct.      When the Unit is ON you may see a  red and/or yellow LED indicator in  the field of view (Fig. 2).  When the  yellow or red LED indicators are  flashing, the remaining battery  power is low and it should be  changed. For uninterrupted operation  keep a fresh battery ready and  FIGURE 2  replace it on time. If the red LED  IR illuminator indicator (red,  indicator is lit solidly, the IR  left), Low
                    
                    Resumen del contenido incluido en la página 15 
                    
                        Switching the Unit off  After you have finished using the Unit, turn it off by rotating the  On/Off/IR/Auto switch to the ‘OFF’ position.  Replace the  objective lens cap.  If storing the unit for an extended period,  remove batteries.  Place Unit in appropriate storage container.  Adjusting to individual vision  Turn on the Unit. Direct the Unit at an object placed within 8-15  m from the viewer.  While looking through the Unit at the object,  first rotate the diopter adjustment ring on the eye
                    
                    Resumen del contenido incluido en la página 16 
                    
                        Auto shut OFF at bright light  Each unit has a built-in high light sensor located near the IR  illuminator (2, Fig. 1). This sensor shuts the monocular off after  -1 about 45 seconds of exposure to light exceeding 10 lux.  To reset the monocular switch it off and then back on as  described in 6.3 and 6.2.   High-light shut-off feature does not mean that the Unit will react  to occasional flashes or bright spots. It protects the tube against  excessive light exposure only in order to avoid perman
                    
                    Resumen del contenido incluido en la página 17 
                    
                        6  Technical  drawing of US  clip mount 1 2  3 5 4 FIGURE 3  1. “Swing arm” mount 4. Unit groove 2. Grooved pad 5. Flip button  3. Locking knob 6. US clip mount  Using the Unit with headgear or helmet  The Unit is supplied with headgear designed to allow the  mounting of the Unit on the head.  Prior to using the headgear  adjust its straps so that the headgear fits the head comfortably but  firmly and does not slide off during movement.   The Unit is attached to the headgear with a swing arm mou
                    
                    Resumen del contenido incluido en la página 18 
                    
                        To set comfortable eye-relief (the distance between your eye and  the eyepiece), loosen tightening screw on the headgear and move  the Unit, then tighten the locking screw.   To use the Unit with PASGT head and helmet mount unscrew  the grooved pad (2, Fig. 3) from the swing arm mount and screw  on the US type clip (6, Fig. 3) using four screws (Fig. 3) instead.  US type helmet clip is optional and must be ordered seperately.  To switch between left and right eye, press the flip button (5, Fig. 
                    
                    Resumen del contenido incluido en la página 19 
                    
                        5.2 Installation of add-on lenses.   Always ensure that the Unit is switched off when adding or  removing an objective lens.    To attach the afocal 3x add-on lens to the Unit, turn off the  monocular. Remove the objective lens cap. Press the 3x lens  firmly towards the eyepiece. Do not apply excessive pressure.  Make sure that the lens is fixed well on the monocular. To return  the monocular back to 1x magnification, pull off the lens.                FIGURE 4    NVS 14 with afocal 3x lens      
                    
                    Resumen del contenido incluido en la página 20 
                    
                        3. To detach the current lens: hold the lens by its base and  rotate it counter-clockwise. Once the lens has been  removed, store it in a safe, clean space.  4. To attach desired lens: rotate it clockwise along the  threading until snug—do not overtighten.   The threads are very fine (to prevent humidity penetration) and  can be damaged easily. Do not apply force when rotating the  lens. If the desired lens does not rotate smoothly along the  threading, make sure that the threads are aligned.  T