Résumé du contenu de la page N° 1 
                    
                         
 
  
 
 
 
 
 
 
 
 
Delta Plus MOBILE II 
GSM/GPRS Class 10 with TCP/IP stack modem 
Part No: ASLH306  
 
User Guide 
 
 
DRAFT COPY 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
ASL Holdings Limited 19/09/2005 1 
Draft Copy Version 2c                                                                                                                                                                                                                                                                                   
                    
                    Résumé du contenu de la page N° 2 
                    
                                            Delta Plus MOBILE II GSM/GPRS Class 10 with  TCP/IP stack modem            ASL Holdings Limited 19/09/2005 2  Draft Copy Version 2c                                                                                                                                                                                                                                                                                                                                                             
                    
                    Résumé du contenu de la page N° 3 
                    
                          Contents      Guide to the manual  Disclaimer   Copyright Notice  Trademarks  Introduction  Features  Connecting to your Terminal or Computer  Supplying power to the modem  Battery Powered version.  Antennae.  Subscriber Identity Module card.  Configuring the modem  AT Command set  Sony Ericsson commands  S Registers  Modem result codes  GPRS operation  Remote access feature  Pay as you go SIM support  LED Status  Technical Specifications  Appendices                                          AS
                    
                    Résumé du contenu de la page N° 4 
                    
                            Delta Plus MOBILE II GSM/GPRS Class 10  With TCP/IP stack modem    Hardware User Guide           Guide to the manual      This manual contains detailed technical information about the Delta Plus  MOBILE II GSM/GPRS modem, including the commands necessary to  configure and use it in your particular application. If you require further  technical detail on this modem, please call our Technical Support Group.      Disclaimer    This manual has been checked for accuracy. The information included 
                    
                    Résumé du contenu de la page N° 5 
                    
                          attention of the Returns Department. No goods will be accepted without a  Return Authorisation Number.   Please enclose a copy of your original purchase invoice, to enable us to  determine the warranty status. If no fault is found, a charge will be made to  cover the costs of testing and carriage.  Your original or replacement modem  will be returned with an engineering report on the fault found. Thank you for  your co-operation.    The Delta Plus MOBILE II is a new low powered high speed GSM/
                    
                    Résumé du contenu de la page N° 6 
                    
                                  The 25 way D-type connector is wired as follows:       Pin number, name and mnemonic:     2 Transmit Data    TxD   3  Receive Data     RxD   4  Request to Send    RTS   5  Clear to Send     CTS   6  Data Set Ready    DSR   7  Signal Ground/Supply Ground  SG   8  Data Carrier Detect     DCD   9 Power In      PI  15  Power In     PI   20  Data Terminal Ready   DTR   22 Ring Indicator     RI         Supplying power to the modem     The Delta Plus MOBILE II GSM/GPRS modem is powered via th
                    
                    Résumé du contenu de la page N° 7 
                    
                          of the modem issuing the “Goodbye” message then it will commence its  power up sequence and restart.    The battery powered modem will power up within 5 seconds after the  external supply is applied given that the battery and capacitors are fully  charged and that the modem is operating at room temperature. If the battery  and capacitors are not fully charged and/or the modem is not operating at  room temperature then the power up sequence will take longer.       Antennae.    The Delta Plus MO
                    
                    Résumé du contenu de la page N° 8 
                    
                            Causes the modem to answer an incoming call.    AT D    Dial Command    Causes the modem to go on line and dial the following telephone number  subject to parameters set in the dial string.    eg: ATDT 12345 123456^m    Where “D” = Dial, “T” = Tone (Compatibility only), ^m = Carriage return.      AT E       Local Echo in command mode.    AT E0 = Local Echo off  AT E1 = Local Echo on    AT H    Hang Up command.    This command causes the modem to disconnect from the telephone line.    AT I   
                    
                    Résumé du contenu de la page N° 9 
                    
                              +CGREG: 0,1    +CHSR: 0    +CHSU: 0    +CMEE: 0    +CMUX: 0,0,1,31,10,3,30,10,2    +CR: 0    +CRC: 0    +CRLP: 61,61,48,6,0    +CRLP: 120,120,48,6,2,3    +CVHU: 2    +ICF: 3,3    +IFC: 2,2    +ILRR: 0    +IPR: 9600    E: 1    M: 0    Q: 0    S0: 001    S10: 002    S2: 043    S3: 013    S4: 010    S5: 008    S6: 002    S7: 050    S8: 002    V: 1    X: 4    Due to the architecture of the interface circuitry not all of the above  commands will necessarily be displayed each time.    ATI 7 disp
                    
                    Résumé du contenu de la page N° 10 
                    
                          Quiet mode. Defines whether or not messages generated by the modem are  sent to the DTE.      AT Q0 = Quiet mode off  AT Q1 = Quiet mode on    AT V    Verbose mode enable. Defines whether the above messages are displayed  as readable text or numeric values.    AT V0 = Verbose mode disabled  AT V1 = Verbose mode enabled    AT X    Result codes. These are the messages generated by the modem when  connection or disconnection is attempted.     There are 5 sets of result codes available (numbered 0
                    
                    Résumé du contenu de la page N° 11 
                    
                            AT &C    Carrier control. This parameter defines the operation of pin 8 (DCD) of the  RS 232C interface.    AT &C0 = Always on  AT &C1 = Fixed to this setting – Carrier goes high when on line.  AT &C3 = Off in command mode – On when modem on line    For compatibility only. ie modem will respond with OK but not take any action.    AT &D    Data Terminal Ready options      This command controls the handling of the DTR line. (Pin 20).     AT&D0 - DTR state is ignored and no action is taken. Thi
                    
                    Résumé du contenu de la page N° 12 
                    
                          013  +CBST: 0,0,1    OK    (On earlier versions of the modem, pre version 2.08 firmware, less information  is displayed when this command is issued).    Due to the architecture of the interface circuitry not all of the above  commands will necessarily be displayed each time.    Issue 3 Hardware:    This displays additional S and P status:    S displays the status of the interface ie.     S0 - The interface is set for sleep mode.   S1 - The interface is permanently on – default.    (Set using A
                    
                    Résumé du contenu de la page N° 13 
                    
                          AT+a     if auto-shutdown is off (ie RS232 on all the time).  (Autosave)    AT+Gn  AT+G0 - turns off GPRS mode.  AT+G1 - turns on GPRS mode and selects the APN.   (Autosave)    AT+I reports ASLH 306 firmware version number, RS232 auto off state (1 =  always on), baud rate, N or E for parity. (F/W dependent)    AT+K Turns Sony Ericsson(™) module off. (Up to F/W version 2.11).  Version 2.12 onwards turns off the complete modem.    AT+O  Turns Sony Ericsson(™) module on. (Assuming modem is turned
                    
                    Résumé du contenu de la page N° 14 
                    
                          Sony Ericsson commands    GPRS related:  ===========    AT+CDGCONT Define PDP Context.     AT+CDGCONT = n,"IP","APN address"    AT*ENAD Ericsson Internet Account Define.     AT*ENAD = n,"GPRS","username","password",1,0    PAYG SIM related:  ==============    AT+CPBS Phone Book Store     AT+CPBS=”ME” (Use “ME” memory location).    AT+CPBW Phone Book Write     AT+CPBW=n,”phone number”,number system,”text”    (See PAYG support section).    AT+CPBR Phone Book Read     AT+CPBR=n (Where n is the “ME
                    
                    Résumé du contenu de la page N° 15 
                    
                            at*e2apc?    Response: *E2APC: 0,1,0,0    Power cycle the modem.    Interrogate modem:     at*e2apc?    Response: *E2APC: 1,1,0,0 (Remote Access enabled)    General  ======    AT+CGMR    This command will cause the Sony Ericsson module to display its  type/version.    Response: R6A023 CXC1122528 (Example).    AT+CBST?    This command gives information regarding the cellular network bearer  channel.     Response: 0,0,1 (Autobaud rate, Asynchronous, Non transparent).      S Registers:    S0= N
                    
                    Résumé du contenu de la page N° 16 
                    
                          1  CONNECT   Connection.   2  RING    Ringing signal detected.   3   NO CARRIER Carrier lost or never present.   4  ERROR   Invalid Command.    6   NO DIAL TONE No dial tone detected.   7  BUSY   Busy signal detected.   8  NO ANSWER No answer from remote modem.       GPRS operation    The three main commands used to set up a GPRS call with the Delta Plus  MOBILE II GSM/GPRS modem in listening mode are as follows:    AT+Gn, where n = 0 to 9  AT+G0 - turns off GPRS mode  AT+G1-9 turns on GPRS mo
                    
                    Résumé du contenu de la page N° 17 
                    
                              Remote Access    The ASLH 306 modem has the ability to be remotely accessed for both testing  and configuration purposes. This is achieved as follows:    1. Establish a normal dial up connection to the ASLH 306 modem.  2. Issue the “***” command to the modem from the remote modem.  3. The ASLH 306 will respond with an OK.  4. You are now connected to the remote 306 PIC interface.  5. If access to the Sony Ericsson module is required issue the AT+Z  command   to the remote modem.  6. The AS
                    
                    Résumé du contenu de la page N° 18 
                    
                            at+t    Modem will then dial number in ME memory 1 (see below).    To store a number:    1/. Set memory to internal memory (not SIM):    at+cpbs="ME" (Phone Book Store command)  OK    2/. Add number:  Text at end can be any characters. Use number system 145 for international  type numbering, or 129 for UK type numbering (see example below).    at+cpbw=1,"441339755397",145,"Top-up" (Phone Book Write command)   OK    3/. Save!    at&w  OK    4/. To read it back, if you wish!    at+cpbr=1 (Phon
                    
                    Résumé du contenu de la page N° 19 
                    
                          LED Status (GSM Mode) Version 2.02 & 2.05    Red LED:     Off for module off.     On when unregistered with network.     Flashes when registered with network.    Green LED:    Slow flash is off line.    Fast flash is on line.    Yellow LED:     Off / Slow flash / On - with increasing signal level.      LED Status (GPRS Mode) Version 2.08 and above    When listening in GPRS you can identify the status of the unit :    Red LED:     Off for module off.     On when unregistered with network.     F
                    
                    Résumé du contenu de la page N° 20 
                    
                          0 or 1 parity bit.     Modem Operation     Controlled by AT commands and supporting S registers.      Data Modulation.     V22 - 1200 bps  V22bis - 2400 bps  V32 2400 – 9600 bps  V110 2400 – 56000 bps  Fax Group 3, Class 1 & 2  HSCSD (2+1), up to 28.8 kbps  GPRS Class B (4+1), up to 85.6 kbps     Equipment Interface   CCITT V.24/V.28    GPRS – Mobile Originate and Listen modes. (Class 10)                                                                         ASL Holdings Limited 19/09/2005 20