■    Cast iron sectional heat exchanger  
and push nipples
■    Vertical flue design
■    Easily assembled with short individual draw rods 
■    Optional tankless heater for dom
                    
                    Résumé du contenu de la page N° 2 
                    
                        Commercial Hot Commercial Hot W Water ater  or Steam Boiler or Steam Boiler Commercial, Forced Draft Commercial, Forced Draft Hot W Hot Water or Steam Boiler ater or Steam Boiler Ten reasons why you need   For Businesses, Institutions, For Businesses, Institutions, Apartments and other Apartments and other  the Series 24 commercial boiler commercial buildings commercial buildings stairs making this boiler ideal for installations  1.  Optimum for large installations –   where the boiler room is n
                    
                    Résumé du contenu de la page N° 3 
                    
                        Top or rear flue outlet  Front mounted  with adjustable lock-type controls for easy  damper includes  adjustment and  tapping for outlet  maintenance pressure readings Left side jacket   panels and cleanouts   for easy access to   all flue surfaces Tankless heater   for domestic   hot water Cast iron vertical   flue design with   pinned heating   surface achieves  maximum heat transfer Burner mounting   plate with flame  Rear cover includes  observation port flame observation   port and plugged  tapp
                    
                    Résumé du contenu de la page N° 4 
                    
                        Series 24 Dimensions (in inches)   1         MAXIMUM FLUTE BURNER                                 BECKETT  APPROX.    NUMBER   NUMBER   NUMBER OF OUTLET MOUNTING   K.D. BLR.   BOILER OF   OF STEAM   HEATERS DIAMETER PLATE WIDTH CF OIL CG GAS SHIPPING   MODEL SECTIONS ‘A’ ‘B’ RISERS ‘C’ ‘D’ ‘E’ ‘F’ ‘G’ ‘H’ ‘H’ WEIGHT LB.  24-03 3 18-1/4 12 1 – 9-1/8 1 7 8 9-3/4 20-7/8 1363  24-04 4 24-1/4 18 1 – 12-1/8 1 7 8 11-3/4 21-5/8 1675  24-05 5 30-1/4 24 1 – 15-1/8 1 8 8 11-3/4 21-5/8 1987  24-06 6 36-1/4
                    
                    Résumé du contenu de la page N° 5 
                    
                        Commercial Hot W Commercial Hot Water or Steam Boiler ater or Steam Boiler Burner Mounting Plates and Adapter Plates Control Tappings BECKETT (“CF” SERIES) BURNER ADAPTER PLATE  TAPPING SIZE     LOCATION (IN.) STEAM BOILER WATER BOILER    I.D. ‘A’ ‘B’ ‘C’   BOILER MODEL PART NO. NO. DIA. DIA. REF. A 4 Supply Supply  24-03 THRU 24-05 330400 920 4-3/4 10 7-1/16 Plug (24-03 thru 24-06)    B 4 Plug    Supply (24-07 thru 24-12)  24-06 THRU 24-08 330401 921 6-1/8 10 7-1/16  C 3 Blow-Off Valve Return  
                    
                    Résumé du contenu de la page N° 6 
                    
                        Series 24 Minimum Piping Recommendations – Water Boiler 1 SUPPLY Recommendation 1 is used   1 when the load is constant and  SUPPLY REAR OF  BOILER not varied due to mixing or  REAR OF DRAIN VALVE (SEE NOTE 4) BOILER multiple zones. Use when: DRAIN VALVE 2A (SEE NOTE 4) ■   system return water is not   1 RETURN 23 2 3” x 12” NIPPLE HEADER less than 135° F for   AND BELL REDUCER (SEE NOTE 3) prolonged periods of time ■   system flow does not impact  2 2B flow through the boiler RETURN RETURN 2 BRAN
                    
                    Résumé du contenu de la page N° 7 
                    
                        SYSTEM PUMP MAX CLOSELY 4D SPACED 1 SUPPLY TEES 3 D DIVERTING VALVE & ACTUATOR SEE NOTE 5 1 SUPPLY BOILER CIRCULATOR 2 RETURN (BY OTHERS - SEE NOTE 5) SEE NOTE 6 DRAIN VALVE (SEE NOTE 4) 3” x 12” NIPPLE AND BELL REDUCER (SEE NOTE 4) REAR OF  2 BOILER RETURN RETURN 24-03 THRU 24-11 (W/20°F DROP) Recommendation 3 is used when the return water temperature goes below 135°F for prolonged p SENSOR eriod (SEE NOTE 7) s of  24-03 THRU 24-12 (W/40°F DROP) time. This is also primary-secondary piping, but 
                    
                    Résumé du contenu de la page N° 8 
                    
                        Commercial Hot W Commercial Hot Water or Steam Boiler ater or Steam Boiler Series 24 Specifications        BURNER  HEATING     WATER  BOILER WEIGHT      NET I=B=R RATING  INPUT SURFACE NET  PRESSURE CONTENT w/ WATER     GROSS      (SQ. FT.)  FIREBOX IN (GAL.) (LBS.) VENT  BOILER HORSE- OUTPUT SQ. FT. MBH MBH OIL GAS   VOLUME FIREBOX     DIA.  MODEL POWER (MBH) STEAM STEAM WATER (GPH) (MBH) STEAM WATER (CU. FT.) (“W.C.”) STEAM WATER STEAM WATER (IN.)  24-03 10.2 342 1071 257 297 3.05 438 34.2 37.0