Résumé du contenu de la page N° 1 
                    
                        APC Smart-UPS  
Uninterruptible Power Supply 
 
Model 5000UXI 
User’s Manual 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
990-7082A REV4  7/01                                                                                                                                                                                                                                                                                                                           
                    
                    Résumé du contenu de la page N° 2 
                    
                                                                  Entire contents copyright © 2000 by American Power Conversion Corporation.  All rights reserved.   Reproduction in whole or in part without permission is prohibited.   APC, Smart-UPS, and PowerChute are registered trademarks of American Power Conversion  Corporation.  All other trademarks are the property of their respective owners.  990-7082A REV4  7/01                                                                                                      
                    
                    Résumé du contenu de la page N° 3 
                    
                        Smart UPS Safety Guide English This Safety Guide contains important instructions that should be followed during installation and maintenance of the APC equipment  and batteries.  It is intended for APC customers who setup, install, relocate, or maintain APC equipment.  Handling Safety  •= Be careful.  Do not lift heavy loads without assistance.  = 32-55 kg (70-120 lb.)   = <18 kg (<40 lb.)   = >55 kg (>120 lb.)   = 18-32 kg (40-70 lb.)     •= Equipment with casters is built to move on a smooth s
                    
                    Résumé du contenu de la page N° 4 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Résumé du contenu de la page N° 5 
                    
                        Table of Contents  Introduction....................................................................................................................................................................1  Unpacking......................................................................................................................................................................1  Installation ...............................................................................................................
                    
                    Résumé du contenu de la page N° 6 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Résumé du contenu de la page N° 7 
                    
                        Introduction  About Your New UPS  This Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags and surges from reaching your computer  and other valuable electronic equipment.  This UPS also filters out small utility line fluctuations and isolates your equipment from  large disturbances by internally disconnecting from the utility line, while supplying power from its external batteries until the utility  line returns to safe levels.  Unpacking   Inspection  Inspect t
                    
                    Résumé du contenu de la page N° 8 
                    
                        2.  Hardwire the Electrical Connection   Caution:  The electrical connection must be made by an authorized electrician according to national and local regulations.   Verify that the supply line contains a 25 Ampere circuit breaker BEFORE hardwiring the UPS.   Ensure that the batteries are not installed in the UPS until the hardwiring is complete.   Incorporate a readily accessible disconnect device in the fixed wiring design.   1. Select the appropriate wire size and connectors.  For most applic
                    
                    Résumé du contenu de la page N° 9 
                    
                        3.  Connect the External Batteries  The SU5000UXI contains no internal batteries. The figure shows the  location of the battery pack connector on the UPS.  Battery pack  connectors are color coded; the 48 Vdc  UXBP48M connector is blue.  Battery pack connectors are also keyed to prevent improper connection.   Do not try to install battery packs with connectors that are a different color  from the battery pack connector in the UPS.  The SU5000UXI can support a maximum of 10 battery packs.    If a
                    
                    Résumé du contenu de la page N° 10 
                    
                        5.  Install PowerChute and Accessories  For additional computer system security, install PowerChute UPS monitoring software.  It provides automatic unattended  ® shutdown capabilities on most major network operating systems.  Once PowerChute is loaded, install the PowerChute  black communication cable between UPS and computer.  See the Software Installation: Instruction Sheet for details.    Notes:  This UPS is equipped with one accessory slot.  See the APC website (www.apc.com) for available ac
                    
                    Résumé du contenu de la page N° 11 
                    
                        Use the HyperTerminal Program to change the number of external battery packs  HyperTerminal is used for Windows 95, Windows 98,  and Windows NT 4.0  1. EXIT out of the PowerChute® plus Server.  In the case of Windows NT, the UPS service must be stopped.  2. From the Desktop, go to: Start => Programs => Accessories => HyperTerminal.  Double-click on the  HyperTerminal icon.  3. You are prompted to choose a name and select an icon. Give any name and then click OK. If a message appears  which reads
                    
                    Résumé du contenu de la page N° 12 
                    
                        Initial Startup   Charge the battery  The UPS charges its battery whenever it is connected to utility power.  The battery will charge fully during the first four  hours of normal operation.  Do not expect full runtime during this initial charge period.  Connect Computer Interface Port (Optional)  Power management software and interface kits can be used with this UPS.  Use only kits supplied or approved by the  manufacturer.  If used, connect the interface cable to the 9-pin computer interface po
                    
                    Résumé du contenu de la page N° 13 
                    
                        Operating Instructions  Switch On — Switch Off     With the UPS plugged in, press and release the large upper on/test button to supply power to the loads.  The loads are  immediately powered while the UPS beeps and performs a self-test.    Press and release the small, lower off button to turn off power to the loads.  It may be convenient to use the UPS as a  master on/off switch for the protected equipment.  Note: Whenever the UPS is plugged in and utility voltage is present, the charger maintai
                    
                    Résumé du contenu de la page N° 14 
                    
                        Load Bar Graph  85% The 5-LED display on the left of the front panel represents the power drawn from the UPS as a percentage of  67% 50% total capacity.  For example, if three LEDs are lit, the load is drawing between 50% and 67% of the UPS’s  33% capacity.  If all five LEDs light, thoroughly test your complete system to make sure that the UPS will not become  17% overloaded.    Overload  When the UPS is overloaded (the connected loads exceed 5000 VA / 3750 W) , the overload LED comes on and the
                    
                    Résumé du contenu de la page N° 15 
                    
                        User Configuration Items  Note: Setting these items requires optional software or hardware.  Function Factory User Selectable Description  Default Choices  Automatic Self-Test Every 14 Every 7 days (168 Sets the interval at which the UPS will  days  hours), On Startup execute a self-test.  (336 hours) Only, No Self-Test  UPS ID UPS_IDEN Up to eight characters Use this field to uniquely identify the UPS  to define the UPS. for network management purposes.  Date of Last Battery Manufacture Date of
                    
                    Résumé du contenu de la page N° 16 
                    
                        Battery Charge and Run Times  Note:   UPS battery life differs based on usage and environment.    The tables below show both the time required for charging UPS and battery pack batteries for rated protection and typical  run times.  Note:  The SU5000UXI is designed for use with the UXBP48M or equivalent 48 Volt battery pack.    Typical Maximum Recharge Times (In Hours) To 90% Of Rated Capacity  Number of Battery Packs Recharge Time Number of Battery Packs Recharge Time  1 5 6 18  2 8 7 20.5  3 1
                    
                    Résumé du contenu de la page N° 17 
                    
                        Troubleshooting  Use the chart below to solve minor UPS installation problems.  Contact APC Technical Support Staff for assistance with  complex UPS problems.  See APC Contact Information  page 12, for a location near you.  Problem and Possible Cause  Solution  UPS will not turn on.  •=ON button not pushed. Press the ON button once to power the UPS and the load.  Check that the power cable from the UPS to the power  •=UPS not connected to AC power supply.  supply is securely connected at both en
                    
                    Résumé du contenu de la page N° 18 
                    
                        Service  If the UPS requires service do not return it to the dealer!   Follow these steps:     1. Review the problems discussed in Troubleshooting, page 14, to eliminate common problems.  2. Verify that no circuit breakers are tripped.  A tripped circuit breaker is the most common UPS problem!   3. If the problem persists, call Customer Service or visit the APC Internet Website (www.apc.com).  •= Note the model number of the UPS, the serial number, and the date purchased.  A technician will ask