                        Instructions Manual  INDEX  RECOMMENDATIONS AND SUGGESTIONS ..................................................................................................................... 3  CHARACTERISTICS ............................................................................................................................................................. 4  INSTALLATION..................................................................................................................................
                    
                    Résumé du contenu de la page N° 3 
                    
                        RECOMMENDATIONS AND SUGGESTIONS   The Instructions for Use apply to several versions of this appliance. Accord- ingly, you may find descriptions of individual features that do not apply to your  specific appliance.  INSTALLATION  • The manufacturer will not be held liable for any damages resulting from incor- rect or improper installation.  • Check that the mains voltage corresponds to that indicated on the rating plate  fixed to the inside of the hood.  • For Class I appliances, check that the 
                    
                    Résumé du contenu de la page N° 4 
                    
                        CHARACTERISTICS  Dimensions          4  EN 4                                                                                                                                                                                                                                                                                                                                                                                                                                                                        
                    
                    Résumé du contenu de la page N° 5 
                    
                        Components  	    Ref. Q.ty Product components   1 1 Cooker hood with control unit, lights,  blower unit, filters   2.1 1 Upper chimney   2.2 1 Lower chimney    8 1 Air outlet grid  
  9 1 Reducer flange Ø 150-120    10 1 Adapting ring ø 120-125 mm   14.1 2 Air Outlet Connection Extension   15 1 Air Outlet Connection     16 1 Cover for recycling version   Ref. Q.ty Installation components   7.2.1 2 Fixing brackets for upper chimney   7.3 1 Air Outlet Connection
                    
                    Résumé du contenu de la page N° 6 
                    
                        INSTALLATION    Hood body mounting  • Firstly, it is necessary to adjust the two Vr-screws of  the 11a-brackets, at minimun (B).  • Hang the hood body on the two brackets 11a.  • Connect the hood to the mains supply by means of a  bipolar switch with at least 3 mm contact gap.  	 • Press the “A”-key for one second (see Part USE) to  open the upper panel.  • Remove the metal filters.    • In order to align the hood it is necessary to adjust the  Vr-screws from inside the hood.    • Fasten t
                    
                    Résumé du contenu de la page N° 7 
                    
                        RECYCLING VERSION AIR OUTLET  To install the hood in recycling version, the optional charcoal     filter kit must be purchased.     • Remove the chimney angle bracket.  • Screw the filter cover onto the air outlet, using four screws 12c  (2.9 x 12.5).  • Fix the air outlet grid 8 on the recirculation air outlet using the  2 screws 12d (2,9 x 9,5) provided.    RECIRCULATION VERSION AIR OUTLET  
   • Insert the connection extension pieces laterally 14.1 in connec- tion 15.  • Insert 
                    
                    Résumé du contenu de la page N° 8 
                    
                        Flue assembly   Upper exhaust flue  • Slightly widen the two sides of the upper flue and  	 hook them behind the brackets 7.2.1, making sure   that they are well seated.   • Secure the sides to the brackets using the 4 screws  	 12c (2,9 x 9,5) supplied.  •  Make sure that the outlet of the extensions pieces is  aligned with the chimney outlets.     Lower exhaust flue  • Slightly widen the two sides of the flue and hook  them between the upper flue and the wall,  mak- ing sure that
                    
                    Résumé du contenu de la page N° 9 
                    
                        USE  Control panel       	   
               Key Function Display  A Upper panel closed: when pressed for about one sec- Indicates the selected speed.  ond it opens the upper panel. It switches the motor on  at the latest  selected speed.  Upper panel open: when shortly pressed it switches  the motor on/off.  B Decreases the suction speed. Number of lit LEDS decreases.  C Increases the suction speed. Number of lit LEDS increases.  D Functioning only when the upper panel is open. This I fl
                    
                    Résumé du contenu de la page N° 10 
                    
                        REMOTE CONTROL (OPTIONAL)  The appliance can be controlled using a remote control  powered by a 1.5 V carbon-zinc alkaline batteries of the  standard LR03-AAA type.  • Do not place the remote control near to heat sources.  • Used batteries must be disposed of in the proper  manner.      Remote control (control panel)           
             T1  Lighting Upper panel closed: opens the upper panel and sets the lights at the maximum inten- sity.     Upper panel open: switches the lights 
                    
                    Résumé du contenu de la page N° 11 
                    
                        MAINTENANCE  Metal grease filters  Filters can be washed in the dish machine. They need to be  washed when Drop-sign appears on the display or in any case  every 2 months, or even more frequently in case of particularly  intensive use of the hood.   Alarm reset  • Press the G–key for at least 2 seconds.  Cleaning the filters   • Open the upper panel by pressing the A-key for 1 second (see  Part USE).   • Remove the filters one by one pushing them towards the back  side of the hood unit and simul
                    
                    Résumé du contenu de la page N° 12 
                    
                        Charcoal filter (recycling version)  This filter cannot be washed or regenerated. It must be replaced when the C appears on the  display or at least once every 4 months. The filter saturation alarm has to be activated already  before.   Activation of the alarm signal   • In the recycling version hoods the filter saturation alarm must be activated during the instal- lation or later.  • Switch off the hood and the lights.  • Press the E-key for about 5 seconds until the last two segments of the mo
                    
                    Résumé du contenu de la page N° 13 
                    
                        Replacing the fuser  The hood panel opening and closing mechanism is con- trolled by a starter motor which is activated by a fuser.  This fuser works only on the starter motor.  In case the  fuser gets damaged when the panel is closed it is be  necessary to manually unblock the panel. In this case  proceed as follows:  • Remove the cover placed up on the left side.  • Press the releasing lever with the screwdriver as  much as necessary to enable the manual opening of  the panel.   • After having
                    