                                    © Adam Equipment Company 2010                                                                                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Résumé du contenu de la page N° 3 
                    
                                CONTENTS      1.0 INTRODUCTION ......................................................................................................3  2.0 SPECIFICATIONS ....................................................................................................4  3.0 INSTALLATION ........................................................................................................5  3.1 UNPACKING ................................................................................................
                    
                    Résumé du contenu de la page N° 4 
                    
                                © Adam Equipment Company 2010  2                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Résumé du contenu de la page N° 5 
                    
                            1.0 INTRODUCTION    • The CBK range of scales provides an accurate, fast and versatile  general purpose weighing scales with parts counting, percent  weighing and check-weighing functions.     • There are two series within the range. The CBKa series are  similar to the CBK series except the CBKa scales can operate in  both imperial and metric weighing units, whereas for the CBK  series the imperial units are not available.     • All models have LEDs to indicate when a weight is below the low
                    
                    Résumé du contenu de la page N° 6 
                    
                                               2.0 SPECIFICATIONS        CBK 4 CBK 8H CBK 8 CBK 16 CBK 32 CBK 48  Kilograms  Maximum Capacity 4 kg 8 kg 8 kg 16 kg 32 kg 48 kg  Tare Range -4 kg -8 kg -8 kg -9.9995 kg -32 kg -48 kg  Readability 0.0001 kg 0.0001 kg 0.0002 kg 0.0005 kg 0.001 kg 0.002 kg  Repeatability (S.D.) 0.0001 kg 0.0001 kg 0.0002 kg 0.0005 kg 0.001 kg 0.002 kg  Linearity (±) 0.0002 kg 0.0002 kg 0.0004 kg 0.001 kg 0.002 kg 0.004 kg  Grams  Maximum Capacity 4000 g 8000 g 8000 g 16000 g 32000 g 48000 g  
                    
                    Résumé du contenu de la page N° 7 
                    
                             OTHER SPECIFICATIONS    Units of measure CBK Series- kg, g   CBKa Series- kg, g, lb, oz, lb:oz    Interface RS-232 bi-directional Interface   Optional USB Serial interface    Stabilisation Time 2 Seconds typical    Operating Temperature -10°C to 40°C  14°F to 104°F  Power supply  230 VAC 50/60 Hz    115 VAC available  Battery Internal rechargeable battery (~90 hours operation)    Calibration Automatic External    Display 6 digits LCD digital display  with capacity tracker and symbols for un
                    
                    Résumé du contenu de la page N° 8 
                    
                            3.2 LOCATING     • The scales should not be placed in a location  that will reduce the accuracy.     • Avoid extremes of temperature. Do not place  in direct sunlight or near air conditioning    vents.         • Avoid unsuitable tables. The table or floor    must be rigid and not vibrate.     • Avoid unstable power sources. Do not use      near large users of electricity such as welding    equipment or large motors.    • Do not place near vibrating machinery.    • Avoid high humidity that mi
                    
                    Résumé du contenu de la page N° 9 
                    
                          3.2 SETTING UP       • The CBK Series comes with a stainless steel platform packed  separately.     • Place the platform in the locating holes on the top cover.     • Do not press with excessive force as this could damage the load  cell inside.    • Level the scale by adjusting the four feet. The scale should be  adjusted such that the bubble in the spirit level is in the centre of  the level and the scale is supported by all four feet.         • Attach the power cable to the connector on the 
                    
                    Résumé du contenu de la page N° 10 
                    
                            4.0 KEYPAD        KEYS PRIMARY FUNCTION   SECONDARY FUNCTION    [Zero] Sets the zero point for all subsequent  Escape from any setting menus  weighing. The display shows zero.     [Tare] It tares the scale and stores the current  Accept the set values  weight in memory as a tare value,   subtracts the tare value from the weight  and shows the results. This is the net  weight.     This is used to select the weighing units  Allows the weight, unit weight,  [Unit]  from a preset list of availab
                    
                    Résumé du contenu de la page N° 11 
                    
                          5.0 DISPLAY               6.0 SYMBOLS AND INDICATORS    The LCD has unique symbols to indicate the following:    The display is at Zero  0    The scale is Stable    Net weight- The scale has been tared  Net    Symbols shown for the units   kg / g / lb / oz / lb:oz     Capacity Tracker- A bar graph indicating the proportion of  the scale capacity being used by the weight on the pan       Low battery   bAt  LO  or     % The scale is in Percent weighing mode  The scale is in Parts counting mode
                    
                    Résumé du contenu de la page N° 12 
                    
                          7.0 BATTERY       • The scales can be operated from the battery, if desired. The  battery life is approximately 90 hours.      • When the battery needs charging a symbol on the display will turn  on. The battery should be charged when the symbol is on. The  scale will still operate for about 10 hours after which it will  automatically switch off to protect the battery.      • To charge the battery, simply plug into the mains power supply.  The scale does not need to be turned on.      • The ba
                    
                    Résumé du contenu de la page N° 13 
                    
                            10.0 OPERATIONS  10.1 ZEROING     • You can press the [Zero] key at any time to set the zero point  from which all other weighing and counting is measured. This will  usually be necessary when the platform is empty. When the zero  point is obtained the display will show the zero indicator.        • The scale has an automatic re-zeroing function to account for  minor drifting or accumulation of material on the platform.  However you may need to press [Zero] to re-zero the scale if  small amou
                    
                    Résumé du contenu de la page N° 14 
                    
                          NOTE:    When the container is removed a negative value will be shown. If the scale  was tared just before removing the container, this value is the gross weight of  the container plus all products which were removed. The zero indicator will  also be on as the platform is back to the same condition it was when [Zero]  was pressed last.    Press [Tare] or [Zero] to remove the tare value and display zero. The Net  indicator will disappear.    10.2.2 Preset Tare     When the scale is at zero with
                    
                    Résumé du contenu de la page N° 15 
                    
                          • If a container is to be used, place this container on the platform  before entering parts counting and press [Tare].         • Press [Count] to enter the Parts Counting mode.  The display will  show the last sample size used.  For example, “10  Pcs”.          • Either place 10 parts on the platform for determining the average  piece weight or use a different number of parts. For example, place  20 parts on the platform, press [CE] to clear the last values and  then enter the value 20 using t
                    
                    Résumé du contenu de la page N° 16 
                    
                                                                                                • To count a different sample quantity, press the [Count] key. The  display will show the last used sample size.  Either use this sample  size with a different part or enter a new sample size as above.     • To return to weighing, press [Unit].      10.5 CHECK-WEIGHING    Check-weighing is a procedure to display an indicator or sound an  alarm when the weight on the scale meets or exceeds the values stored  in the memory.  T
                    
                    Résumé du contenu de la page N° 17 
                    
                          3. If Limit Password is enabled then enter the password which will allow     you to change the limits or the operation of the beeper or bargraph.    10.5.1 Setting up check-weighing while weighing    • Press the [Low Limit] key. It will show the current low limit. The  “LO” symbol will appear on the display.    • Press the [CE] key to clear the old value and then enter the new  low limit using the numeric keys. The decimal point is fixed at the  position that is used for the current weighing u
                    
                    Résumé du contenu de la page N° 18 
                    
                          press [CE] to clear the settings, enter zero and then press [Tare]  to store the zero values.  10.6 LIMITS STORING AND RECALLING     The scale can store up to 10 sets of high and low limits in memory along with  the weighing units in use (including pcs for parts counting and % for percent  weighing) as well as settings for the beeper and bar graph.      During Check weighing the current limits can be stored or previously stored  units can be recalled.      Press the [   Lim] key.   If you 
                    
                    Résumé du contenu de la page N° 19 
                    
                            NOTE:     1. If the recalled limit is for parts counting, the display will show the last  sample value used, ready for a new sample to be counted.      2. If the recalled unit is a percent weighing limit, the display will show the  last sample value used, ready for a new sample to be weighed.      3. If the memory location was empty the scale will return to weighing.       10.7 PERCENT WEIGHING     The scale can be set to perform percent weighing.  See Section 13.1.    The scale will use a m
                    
                    Résumé du contenu de la page N° 20 
                    
                          if 3500g is placed on the scale and percent weighing is selected, the  display will show 100.00%. Remove the 3500g weight and place a  3000g weight. The display will show 85.7% as 3000g is 85.7% of  3500g.        • The number of decimal points will depend on the weight used. A  smaller weight will show only “100%” while a larger weight might show  “100.00%”.       • If the scale was showing zero weight when entering this function, then  the user must manually enter the weight to be set as 100%