Résumé du contenu de la page N° 1 
                    
                         EXCELL PRECISION CO., LTD 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
© Excell Precision Limited 2005.  All rights reserved Worldwide. 
The information contained herein is the property of Excell Precision Limited 
and is supplied without liability for errors or omissions.  No part may be 
reproduced or used except as authorised by contract or other written 
permission.  The copyright and the foregoing restriction on reproduction 
and use extend to all media in which the information
                    
                    Résumé du contenu de la page N° 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    Résumé du contenu de la page N° 3 
                    
                         EXCELL PRECISION CO., LTD.    TABLE OF CONTENTS    INSTRUCTION FOR USE............................................................................................................2  PREPARING TO USE THE SCALE.............................................................................................2  CHAPTER 1 FEATURES AND SPACIFICATIONS......................................................................3  1. Features ..........................................................................
                    
                    Résumé du contenu de la page N° 4 
                    
                         EXCELL PRECISION CO., LTD.    INSTRUCTION FOR USE  Thank you for purchasing the 9903 Dolphin II weighing scale of Excell. To enable you to use this  scale correctly, we suggest that you read the following instructions carefully.     1. Don’t bump the scale against other items nor load it with heavy weight exceeding its full  capacity.  2. Keep it away from high temperature.  3. If the scale is not going to be used for a certain period of time, clean it and store it in a  polythene bag. A desicc
                    
                    Résumé du contenu de la page N° 5 
                    
                         EXCELL PRECISION CO., LTD.    CHAPTER 1 FEATURES AND SPACIFICATIONS  1. Features  2 IP65 Wash down design   2 Auto calibration  2 Large LCD display with LED backlight included  2 Kilogram (kg) and pound (lb) weighing modes  2 Full range tare; Auto zero tracking   2 Adjustable gravity value  2 Simple counting; Gross/Net indication; Hold function; Check mode Lo/Hi/OK  2 Low power indication and auto power off   2 Easily adjusted leveling feet for stability of the scale        2. Options  2 Second
                    
                    Résumé du contenu de la page N° 6 
                    
                         EXCELL PRECISION CO., LTD.      4. Power Supply  Power Source: AC 110V/230V (±10%) adaptor;  4 x UM-1 1.5V dry batteries; or  6V / 1.2Ah rechargeable battery    Power Consumption:  With backlight: about DC 14 mA; battery life about 85 hours  Without backlight: about DC 24 mA; battery life about 50 hours    Low Battery Indication: When the symbol   flashes, the battery needs to be  recharged or the dry battery needs to be replaced.    4 The scale will power off automatically after 1 to 2 hours i
                    
                    Résumé du contenu de la page N° 7 
                    
                         EXCELL PRECISION CO., LTD.    CHAPTER 2 DISPLAY  1 2 3 4 5 6 7      HI :  When this indicator is on, the weight value is larger than the preset high limit.  OK :  When this indicator is on, the weight value is between the low and high limits.  LO :  When this indicator is on, the weight value is less than the preset low limit.  kg :  Indicating that the current weighing unit is “kg”.  lb :  Indicating that the current weighing unit is “lb”.  Pcs :  Indicating that the scale is in the simple cou
                    
                    Résumé du contenu de la page N° 8 
                    
                         EXCELL PRECISION CO., LTD.    CHAPTER 3 KEYBOARD FUNCTION  OFF  1.  :  Pressed to switch the scale off      ON    ZERO  2.  :  When the scale is off, pressed to switch it on.     When the scale is on, if the weight is within the zero range, this key is pressed  to re-zero the display or cancel the tare mode.  4 Zero range:  OIML & NTEP: ±2% of full scale;  Sri Lanka: ±4% of full scale      TARE  3.  :  Pressed to deduct the container weight.      UNITS  4.  :  Pressed to choose the unit weight 
                    
                    Résumé du contenu de la page N° 9 
                    
                         EXCELL PRECISION CO., LTD.    CHAPTER 4 BASIC FUNCTION OPERATION  1. Switch On  ON    ZERO  When the scale is off, press the  key to switch on the scale            2. Re-Zero  When there is no load on the platter, if the displayed weight is not zero and is within the  ON    ZERO  zero range, press the  key to re-zero the scale, and the indicator “à0ß” is on.      4 Zero range:  OIML & NTEP: ±2% of full scale;  Sri Lanka: ±4% of full scale          3. Unit Selection  UNITS  Press the  key to cho
                    
                    Résumé du contenu de la page N° 10 
                    
                         EXCELL PRECISION CO., LTD.    4. Tare Function      (1) Put the container on the platter. When the weight displayed is stable, press the  TARE   key. The weight of the container is thus deducted, and the “Net” indicator is  on.      (2) Put the object to be weighed into the container, and the display shows the net weight of  the object.      (3) Remove the container and the object together from the platter. The display will show the  negative value of the container weight.  TARE      (4) Press 
                    
                    Résumé du contenu de la page N° 11 
                    
                         EXCELL PRECISION CO., LTD.    6. Simple Counting     6-1 Counting mode access  UNITS  Press the  key to select the “Pcs” unit, and the scale enters the simple  counting mode.       6-2 Sampling         This important procedure is to let the scale calculate the unit weight:  NET    GROSS  (1) Press the  key to select a sample size 10, 20, 50, 100 or 200.    (2) Put enough samples onto the platter according to the selected number, and then  UNITS  press the  key. The display shows “- - - - - -” f
                    
                    Résumé du contenu de la page N° 12 
                    
                         EXCELL PRECISION CO., LTD.    CHAPTER 5 ADVANCED FUNCTIONS SETTING  4 To access the advanced functions setting, press the  NET/GROSS  key and the    ON/ZERO  key at the same time when the scale is in the weighing mode. The  display shows         .              Press the  UNITS  key                 Press the  ON/ZERO  key   Press the  UNITS  key                          Press the  ON/ZERO  key  Press the  UNITS  key            Press the  ON/ZERO  key                                       ⇒  Func
                    
                    Résumé du contenu de la page N° 13 
                    
                         EXCELL PRECISION CO., LTD.      1. Function Setting            4 Six functions          ~          can be set here.                             Press the  TARE  key                         Input “00 ~ 06”                           If input “00”, press the   TARE     key to return to the upper level     category.   ON/ZERO  ⇒ Upward digit selecting (0-9)             UNITS  ⇒ Downward digit selecting (9-0)               TARE  ⇒ Move the cursor rightward         NET/GROSS  ⇒ Move the cursor leftwa
                    
                    Résumé du contenu de la page N° 14 
                    
                         EXCELL PRECISION CO., LTD.      1-1 Auto Backlight Setting                                     Press the  TARE  key    The display shows the current    backlight setting.                     Press the  ON/ZERO  or  UNITS    key to select “on” or “off”.    Auto backlight setting       on ⇒ Turn on the auto backlight         off ⇒ Turn off the auto backlight                    Press the  TARE  key                                     Auto backlight mode        1. When there is weight on the platte
                    
                    Résumé du contenu de la page N° 15 
                    
                         EXCELL PRECISION CO., LTD.      1-2 Auto-off Timer Setting                                  Press the  TARE  key    The display shows the current setting                     Auto-off timer setting     0 ⇒ Auto-off not functional  Press the   ON/ZERO     1 ⇒ If the scale is not operated for 1 minute,  or  UNITS  key to input    it will automatically switch off.  a parameter     2 ⇒ If the scale is not operated for 2    minutes, it will automatically switch off.                          9 ⇒ If th
                    
                    Résumé du contenu de la page N° 16 
                    
                         EXCELL PRECISION CO., LTD.      1-3 Check-Weighing Setting          4 If both the preset high limit and the low limit values are set as 0, the check-weighing  function is invalid.                       Press the  TARE  key    The display shows the current    setting of high limit value    kg        .          Input the desired high limit value      kg            .         Press the  TARE  key The display shows the current    setting of low limit value   kg           .      Input the desired low
                    
                    Résumé du contenu de la page N° 17 
                    
                         EXCELL PRECISION CO., LTD.      1-4 Restore to the Factory Setting                                       Press the  TARE  key   Return to upper level category    (abort restoring)                  Press the  ON/ZERO  or  UNITS    key to select “return” or “format”.    Restore to the factory setting                     Press the  TARE  key                                 4  The restored factory settings include the following:       (1)  External weight calibration       (2)  Check-weighing setti
                    
                    Résumé du contenu de la page N° 18 
                    
                         EXCELL PRECISION CO., LTD.    1-5 Environment Parameter Setting          4 The parameters in      remain the same after the ones has been modified  in            Return-to-zero-point setting      The display shows the current setting              Return-to-zero-point setting  Press the  TARE  key      Default setting = 0       0 ⇒ No skip      5 ⇒ skip 5d         1 ⇒ skip 1d      6 ⇒ skip 6d                2 ⇒ skip 2d      7 ⇒ skip 7d       3 ⇒ skip 3d      8 ⇒ skip 8d  Use the  ON/ZERO  or  UN
                    
                    Résumé du contenu de la page N° 19 
                    
                         EXCELL PRECISION CO., LTD.      1-6 Hold Function Setting                             Press the  TARE  key    The display shows the current hold    function mode                     Use the  ON/ZERO  or  UNITS   Hold function setting    key to input a parameter  Default setting = 0       0 ⇒  No hold function     1 ⇒  “peak” hold function mode              2 ⇒  “stable” hold function mode 1     3 ⇒  “stable” hold function mode 2   Press the  TARE  key                        Input “00”          
                    
                    Résumé du contenu de la page N° 20 
                    
                         EXCELL PRECISION CO., LTD.       2. External Weight Calibration                                  The display shows the calibration    Press the   TARE  key  weight (equals to the full capacity) and    the weight unit. The last digit flashes.    kg   4  The calibration weight can be        .     modified if necessary.    Put the platter on and make sure    there is no weight on the platter.    Then press the  TARE  key.    The scale is calculating the internal    kg   value of the zero point.