Résumé du contenu de la page N° 1 
                    
                        C
E
N
R
G
T
I
     
 
                      CD32M(-1)(-2) 
 
 
                                CD36M(-1)(-2)  
 
 
                                    CD42M  
 
                  DIRECT VENT GAS FIREPLACE 
                                           
                                                  INSTALLATION INSTRUCTIONS
 
 
SAVE THIS BOOK 
 
This book is valuable.  In addition to instructing you on how to install and maintain your appliance, it also contains information that will
 
enable yo
                    
                    Résumé du contenu de la page N° 2 
                    
                              CONTENTS      1. INTRODUCTION    ------------------------------------------------------------  PG. 2      2. SELECTING LOCATION   -------------------------------------------------------------  PG. 2      3. MINIMUM CLEARANCES   -------------------------------------------------------------  PG. 3      4. VENT PIPE AND TERM. CLEARANCES  -------------------------------------------------------------  PG. 3-4      5.  VENTING INSTRUCTIONS                     ------------------------------------
                    
                    Résumé du contenu de la page N° 3 
                    
                         a) Modification of the fireplace, components, doors, blower,  FOR YOUR SAFETY   fans, air inlet system and damper control.   • Do not store or use gasoline or any other flammable  b) Use of any component part not manufactured or approved  vapors or liquids in the vicinity of this or any other  by DESA/Coleman in combination with a DESA/Coleman  appliance.   fireplace system.  • Due to high temperatures, the appliance should be    located out of traffic and away from furniture and  PROPER INSTAL
                    
                    Résumé du contenu de la page N° 4 
                    
                        In selecting a location, the following precautions must be   WARNING: Do not block required air space with observed:   insulation or any other material.  Do not obstruct    effective opening of appliance with any type of facing  Do not connect this appliance to a chimney system   material.  used for solid fuel burning fireplace.    Due to high temperatures, do not locate this appliance   in high traffic areas or near furniture and draperies. VENT TERMINATION CLEARANCES   Never obstruct the front
                    
                    Résumé du contenu de la page N° 5 
                    
                        VENT PIPE AND TERMINATION CLEARANCES     The final position of your appliance depends on the location of the termination in relation to the clearances that must be observed.                                                              A= 12” (305mm) clearance above grade, veranda, porch, deck G= 6” (15mm) clearance to inside corner.  or balcony. *** H= not to be installed above a meter/regulator within 3 feet  B= 9” (229mm) clearance in U.S. and 12” (305mm) clearance (914mm) horizontally from th
                    
                    Résumé du contenu de la page N° 6 
                    
                        VENT INSTALLATION INSTRUCTIONS 7. An optional siding standoff may be installed between   the vent cap exterior wall.  Secure horizontal top to  1. Install pipe to fireplace collar adapter located on back standoff and then secure the complete assembly to  of unit at a 45 deg. Angle.  Connect our starting pipe wall (see figure 6).  The vent termination must be  to a 45 deg. Starting section by sliding it over the removable for service pipe inspection.  collar adapter on the fireplace.  Twist-lock 
                    
                    Résumé du contenu de la page N° 7 
                    
                        Refer to the following table for clearance between roof and   termination.         ROOF PITCH MINIMUM HEIGHT ABOVE ROOF    ft mm    FLAT - 7/12 1 305    7/12 - 8/12 1.5 457    8/12 - 9/12 2 610    9/12 - 10/12 2.5 762    10/12 - 11/12 4 1219    12/12 - 14/12 5 1524    14/12 - 16/12 6 1829    16/12 - 18/12 7 2134    18/12 - 20/12 7.5 2286 Figure 9          CORNER INSTALLATION   20/12 - 21/12 8 2438     FRAMING      CD32M CD36M CD42M Once the final location has been determined (observing   A 28-1/
                    
                    Résumé du contenu de la page N° 8 
                    
                        The remote control receiver is factory wired and connected to In conformance with local codes, route a ½” NPT gas line  the convertible gas valve as shown in figure 11. towards the appliance coming in from either the left or right   side of the fireplace (see figure 14).      CAUTION: Do not kink flexible gas line.                                                   Figure 12           GAS CONTROL VALVE       Figure 11      REMOTE CONTROL RECEIVER           GAS SUPPLY TESTING      NOTE: This secti
                    
                    Résumé du contenu de la page N° 9 
                    
                        Install a sediment trap between the incoming gas line and the   CAUTION: All gas piping and connections must be tested gas control box (see figure 15).  The sediment trap should   for leaks after the installation is completed.  After ensuring extend down a minimum of 3 inches (76 mm) beyond the   that the gas valve is on, apply a commercial leak detection center of the pipe.   solution to all connections and joints.  Bubbles forming    show a leak.  Correct all leaks at once.  DO NOT USE AN    O
                    
                    Résumé du contenu de la page N° 10 
                    
                        GLASS PANEL REMOVAL FOR MODELS CD32M AND CD36M SERIES  Before proceeding, make sure gas control valve is in the  • Place log #1 (back log) on top of grate.  Make sure  “OFF” position.  the notches in the bottom of the log fit over the grate.  1. To remove louvers, pull both spring latches (located  • Rest log #2 (large front log) on the pins on the front  in each end of louver) towards center of appliance  part of the grate.  simultaneously until disengaged from locating holes.   • Place log #3 
                    
                    Résumé du contenu de la page N° 11 
                    
                        • Place log #6 (left log) onto left pin of front log (#2)   WARNING: Improper installation, adjustment,   and the smooth surface of rear log (#3).  Make sure it  alteration, service or maintenance can cause injury or is seated properly.   property damage.  Refer to this manual for assistance.   • Place log #7 onto right pin of top log (#5). Make sure  Consult a qualified installer for additional information.    it is seated properly.                                                      NOTICE: D
                    
                    Résumé du contenu de la page N° 12 
                    
                                                                                                                                 - 11 -                                   For more information, visit www.desatech.com                                                                                                                                                                                                                                                                                                                      
                    
                    Résumé du contenu de la page N° 13 
                    
                        CONVERSION KIT • Replace pilot orifice with LP orifice supplied with    this kit.    The number 30 is stamped on the sleeve for  This conversion kit is packaged with the unit.  Please check identification.  Insert the small end of the new pilot  the contents before beginning this conversion.  orifice into the barrel and thread until tight with the   allen wrench.  • Before proceeding, make sure the gas control valve is   in the “OFF” position and all electrical power to the  • Line up the notch 
                    
                    Résumé du contenu de la page N° 14 
                    
                        • Install the identification label enclosed with the FACE EXTENSION (FOR MODEL CD32M ONLY)    gas valve regulator to the valve body where it can  easily be seen (see figure 23). Model CD32M comes equipped with a front face extension.   The front face extension would add 3- ½” to the width and ¾”     to the height of the fireplace face.       To install the face extension:       • Remove the existing screws from front face assembly   as shown in figure 24.       • Align holes on top face extensio
                    
                    Résumé du contenu de la page N° 15 
                    
                                OBSERVED PROBLEM                   POSSIBLE CAUSE      REMEDY    • Pilot will not stay lit after • Defective pilot generator • Check pilot flame.  It must  carefully following lighting (thermocouple). impinge on thermocouple.  instructions.   • Clean or adjust pilot for    maximum flame impingement on     thermocouple.     • Ensure that the connection     between the valve and     thermocouple are tight and     secured.                 • Pilot lit but no flame on the • Remote or wires de
                    
                    Résumé du contenu de la page N° 16 
                    
                          ILLUSTRATED PARTS BREAKDOWN    MODELS CD32M AND CD36M SERIES                                                                                                          - 15 -                                   For more information, visit www.desatech.com                                                                                                                                                                                                                                                       
                    
                    Résumé du contenu de la page N° 17 
                    
                          ILLUSTRATED PARTS BREAKDOWN    MODEL CD42M                                                                                                          - 16 -                                   For more information, visit www.desatech.com                                                                                                                                                                                                                                                                         
                    
                    Résumé du contenu de la page N° 18 
                    
                          ILLUSTRATED PARTS LIST      ITEM PART # DESCRIPTION QTY. CD32M CD36M CD42M 1 108878-01 108008-01 108326-01 FIREBOX ASSEMBLY 1 2 108874-01 108009-01 108327-01 FACE WELDMENT 1 3 108892-01 108010-01 108328-01 DOOR ASSEMBLY 1 4 108903-01 108011-01 108331-01 PANEL ASSEMBLY LOUVER, FACE TOP 1 5 108903-02 108011-02 108331-03 PANEL ASSEMBLY LOUVER, FACE BOTTOM 1 6 108895-01 108015-01 108333-01 TOP, FIREPLACE 1 7 109096-01 108016-01 108336-01 INSULATION, FIREPLACE TOP 1 8 108896-01 108017-01 108334-01 
                    
                    Résumé du contenu de la page N° 19 
                    
                           ACCESSORY AND REPLACEMENT PARTS                                                                                                        - 18 -                                   For more information, visit www.desatech.com