Résumé du contenu de la page N° 1 
                    
                        INSTALLATION  INSTRUCTIONS
AND
OWNER'S  MANUAL
GRAVITY VENTED 
SINGLE WALL  FURNACE
MODEL
GWT-25-2(SG, RB)
GWT-35-2(SG, RB)
EFFECTIVE  DATE 
APRIL 2006
WARNING:  If the information in this 
manual is not followed exactly, a fire or 
explosion may result causing property 
damage, personal injury or loss of life.
 — Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity 
of this or any other appliance.
Installer: Please leave these instructions with 
  — WHAT TO DO IF Y
                    
                    Résumé du contenu de la page N° 2 
                    
                        TABLE OF CONTENTS SECTION PAGE Important Safety Information .................................................................................................3 Safety Information for Users of LP Gas .................................................................................4 Introduction ............................................................................................................................5 Specifications ..................................................................
                    
                    Résumé du contenu de la page N° 3 
                    
                        IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT OUTER CASING INSTALLED. • Due to high temperatures the appliance should be located • DO NOT put anything around the furnace that will  out of traffic and away from furniture and draperies. obstruct the flow of combustion and ventilation air. • Children and adults should be alerted to the hazards of • DO keep the appliance area clear and free from  high surface temperatures and should stay away to avoid c
                    
                    Résumé du contenu de la page N° 4 
                    
                        SAFETY INFORMATION FOR USERS OF LP-GAS by point with the members of your household. Someday  Propane (LP-Gas) is a flammable gas which can cause fires  and explosions. In its natural state, propane is odorless and when there may not be a minute to lose, everyone's safety  will depend on knowing exactly what to do. If, after read- colorless. You may not know all the following safety precau- tions which can protect both you and your family from an ing the following information, you feel you still ne
                    
                    Résumé du contenu de la page N° 5 
                    
                        INTRODUCTION Introduction Installation in Residential Garages Vented wall furnace is shipped ready to install in a 2" x 4"  stud Gas utilization equipment in residential garages shall be installed  wall, with studs 16" (406mm) center to center.  Always consult so that all burners and burner ignition devices are located not less  your local Building Department regarding regulations, codes than 18" (457mm) above the floor. or ordinances which apply to the installation of a  vented wall  Such equipm
                    
                    Résumé du contenu de la page N° 6 
                    
                        RECOMMENDED VENT CONFIGURATION Note:  No vent equipment supplied with furnace. 4" Oval (all parts purchase locally)  1. Type B-1 oval pipe  2. Single story type B-1 gas vents require a baseplate and one pair of  ceiling plate spacers.  3. Multi-story type B-1 gas vents require a baseplate, one pair of ceiling  plate spacers at the first floor ceiling and one pair of fire stop spacers  at each successive ceiling level. Type B-W gas vent pipe is available for single story or  multi-story installation
                    
                    Résumé du contenu de la page N° 7 
                    
                        GAS SUPPLY Check all local codes for requirements, especially for the size and  type of gas supply line required. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Tubing, Type L    (feet) Inside Diameter Outside Diameter   Nat. L.P. Nat. L.P.  0-10 1/2" 3/8" 1/2" 3/8"   12.7mm 9.5mm 12.7mm 9.5mm  10-40 1/2" 1/2" 5/8" 1/2"   12.7mm 12.7mm 15.9mm    12.7mm  40-100 1/2" 1/2" 3/4" 1/2"   12.7mm 12.7mm 19mm       12.7mm  100-150 3/4" 1/2" 7/8" 3/4"   19mm 12.7mm 22.2mm 19mm Note: Never use 
                    
                    Résumé du contenu de la page N° 8 
                    
                        CLEARANCES  1. In selecting a location for installation, it is necessary to NOTE:  Minimum distance of 1 1/2" (38mm) must also be  provide adequate accessibility clearances for servicing and maintained from top surface of carpeting, tile, etc. proper installation.  2. Clearances to combustible surfaces are 4" (102mm) from  sides, 12" (305mm) to top, 1 1/2" (38mm) from floor. VENTILATION AND COMBUSTION AIR Wall furnaces shall be installed in a location in which the facilities Where appliances are 
                    
                    Résumé du contenu de la page N° 9 
                    
                        62 1/4 ” (1581 mm) 14 ½” 66 1/8 ” (1679mm) (368 mm) W ALL OPENING Figure 2 Figure 3 FINISHING INSTRUCTIONS Plastering (Figure 4) Installing Furnace (Figure 5) Clear the recess of all debris, and remove any wood plaster-grounds.  In new construction use only plain (not perforated) gypsum lath  Stand the furnace on floor in front of wall opening. around furnace and vent pipe so that plaster "Keys" will not project  into wall space.  Insert furnace flue into rectangular opening in header plate and  r
                    
                    Résumé du contenu de la page N° 10 
                    
                        FINISHING INSTRUCTIONS (continued) IMPORTANT — Avoid securing too tightly and disturbing the  inner casing.  Do not try to force furnace into a wall opening which  is smaller than specified dimension. OUTER CASING (Figure 6) 1. Align 1 3/4" slot on casing bracket with bottom screw hole on  inner casing. Attach casing bracket to inner casing with one (1)  10 x 1/2" screws for each casing bracket. Do not completely  tighten screws at this time. 2. Place outer casing onto header.   Attention: Use ce
                    
                    Résumé du contenu de la page N° 11 
                    
                        THERMOSTAT LOCATION (SG MODELS) CAUTION — Do not run wire behind flanges of Header Plate Connect thermostat wires to gas valve as shown in Figure 7. or in any location where it might be damaged.   Millivolt wall thermostats are specially designed for use on self- generating systems.  They should never be used on line or low  voltage A.C. circuits. Interior Wall — The thermostat should be installed on an inside  wall away from the furnace but in the same room.   Note:  Use 16 gauge wire to prevent
                    
                    Résumé du contenu de la page N° 12 
                    
                        LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:  If you do not follow these instructions exactly, a fire or explosion may result  causing property damage, personal injury or loss of life. A.  This appliance has a pilot which must be lighted by • If you cannot reach your gas supplier, call the fire  hand.  When lighting the pilot, follow these instructions department. exactly. C.  Use only your hand to push in or turn the gas control  B.  BEFORE LIGHTING  smell all around the ap
                    
                    Résumé du contenu de la page N° 13 
                    
                        VENT SAFETY SHUTOFF SYSTEM This appliance must be properly connected to a venting system.   This appliance is equipped with a vent safety shutoff system. Warning:  Operation of this wall furnace when not  connected to a properly installed and maintained venting  system or tampering with the vent safety shutoff system  can result in carbon monoxide (CO) poisoning and possible  death. This furnace is equipped with a manual reset vent safety switch.   The manual reset vent safety switch will cause 
                    
                    Résumé du contenu de la page N° 14 
                    
                        TROUBLESHOOTING GENERAL   All furnaces have been fire-tested to check for Knob  proper operation.  This includes main burner flame, pilot flame, 1. Follow instructions and hold gas control knob down longer  and gas control operation.  If the furnace fails to function on initial and harder. installation, it is advisable to re-check the following: 2. Determine if pilot flame extends past thermopile; if not,  1. Inlet gas pressure. adjust pilot flame or clean pilot burner. 2. Type of gas being used and 
                    
                    Résumé du contenu de la page N° 15 
                    
                        PARTS LIST ATTENTION: When ordering parts, it is very important that part number and description of part coincide. Index Part Index Part   No. Number Description   No. Number Description  14 GWT-015 AIR SHUTTER REAR- GWT-25-2   1 WFA-115 HEADER GASKET LPG   2 GWT-175 HEADER ASSEMBLY (INCLUDES   14 GWT-012 AIR SHUTTER REAR - GWT-35-2  NO. 1, GASKET) (USA) LPG   2 15740 HEADER ASSEMBLY (INCLUDES  NO. 1, GASKET) (CANADA) 15 GWT-054 AIR SHUTTER BOTTOM - GWT-25-2  LP   3 GWT-182 INNER CASING ASSEMBLY
                    
                    Résumé du contenu de la page N° 16 
                    
                        PARTS VIEW 1 4 2 3 6 5 7 23 8 22 24 25 17 9 18 26 19 10 21 12 20 27 13 11 14 16 15 Page 16   12425-7-0406                                                                                                                                                                                                                                                                                                                                                                                                           
                    
                    Résumé du contenu de la page N° 17 
                    
                        REMOTE BULB CONTROL INSTALLATION INSTRUCTIONS MODELS GWT-25 RB, GWT-35 RB, GWT-50 RB Index Part  No. Number Description  1 GW-130 Remote Bulb Control Kit  2 R-1224 Remote Bulb Control  3 R-2499 Wire Assembly  4 R-1162 Control Knob  5 R-1720 Plastic Clip (3 Required)  6 R-1223 Instructions  7 R-1578 No. 6-32 x 1/4" (6mm) Screw (2 Required) Caution:   Remote bulb wire routing is important.  Wires should be  in proper location to avoid damage from being overheated.   Incorrect routing of remote bul
                    
                    Résumé du contenu de la page N° 18 
                    
                          OPTIONAL BLOWER INSTALLATION INSTRUCTIONS GWTB-2 FOR MODELS GWT-25 (SG, RB), GWT-35 (SG, RB), GWT-50 (SG, RB) Installing Blower Using Three-Prong Plug Caution: When installing blower housing onto wall be careful motor   1. Install furnace according to Installation Instructions and Owner's coil is not damaged. Manual.  Installing Blower With Hard Wiring  2. Refer to Drawing for measurements to locate (2) mounting holes   1. When facing the wall opening, install 120V electrical outlet junction  
                    
                    Résumé du contenu de la page N° 19 
                    
                        GWTB-2  WIRING DIAGRAM 13 ” (330 mm)   4 7/16 ” (1 12.6 mm) Figure 3 Fan Control The automatic fan control is located on the bottom of the blower assembly.  The fan control is a nonadjustable, automatic type. The fan control will  require between 3 and 7 minutes of main burner operation before the fan  control "closes" and activates the blower. The blower will continue to  run between 3 and 7 minutes after the main burner shuts off, before the  fan control "opens" and deactivates the blower. Wir
                    
                    Résumé du contenu de la page N° 20 
                    
                        SERVICE NOTES PH: 1-618-233-7420 PH: 1-800-851-3153 FAX: 1-618-233-7097 Empire Comfort Systems, Inc. FAX: 1-800-443-8648 Nine Eighteen Freeburg Ave. E-MAIL: info@empirecomfort.com Belleville, Illinois  62220-2623 WEB SITE: www.empirecomfort.com Page 20   12425-7-0406