                        DIRECT-VENT FIREpla CE
OWNER’S OpERa TION aND INSTalla TION MaNUal
NaTURal GaS “TUDOR” MODES (V)T32N- l a SERIES  
aND CGDV32NR
RO p paNE/ G lp aS “TUDOR” MODES (V)T32 l -p a SERIES  
aND CGDV32pR
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of this or any other 
appliance.
— WHAT TO DO IF YOU SMEL
                    
                    Résumé du contenu de la page N° 2 
                    
                        TablE OF CONTENTS Safety Information ...............................................  Cleaning and Maintenance ................................ 30 Product Identification ........................................... 4 Troubleshooting ................................................. 3 Local Codes......................................................... 4 Replacement Parts ............................................ 36 Product Features ................................................. 4 Service 
                    
                    Résumé du contenu de la page N° 3 
                    
                        SaFETy INFORMa TION Keep the appliance area clear  Continued and free from combustible ma- Carbon Monoxide Poisoning: Early signs of carbon terials, gasoline and other flam- monoxide poisoning resemble the flu, with head- mable vapors and liquids. aches, dizziness or nausea. If you have these signs,  the fireplace may not be working properly. Get  Do not place clothing or other  fresh air at once! Have fireplace serviced. Some  flammable material on or near  people are more affected by carbon mo
                    
                    Résumé du contenu de la page N° 4 
                    
                        SaFET INFORM y a TION OC l al CODES Continued Install and use fireplace with care. Follow all local  codes. In the absence to local codes, use the cur- 9. Do not use this fireplace to cook food or burn  rent National Fuel Gas Code ANSI Z223.1/NFPA  paper or other objects. 54* (USA) or the current CSA-B149.1 Installation  10. This appliance, when installed, must be electri- Code (Canada). cally grounded in accordance with local codes  *Available from: or, in the absence of local codes, with the  
                    
                    Résumé du contenu de la page N° 5 
                    
                        • There must not be any obstruction such as bushes,  pRE-INST alla TION  garden sheds, fences, decks or utility buildings  pREa p Ra TION within 24" from the front of the termination cap. LOCATION AND Sp ACE • Do not locate termination cap where excessive  snow or ice build up may occur. Be sure to clear  REUIREMENTS q vent termination area after snow falls to prevent  Determine the safest and most efficient location  accidental blockage of venting system. When  for your DESA direct-vent firepla
                    
                    Résumé du contenu de la page N° 6 
                    
                        pRE-INST alla TION  pREa p Ra TION 5 3 D 1 Continued 13 B / " 9 /" 39 C /8" 8  1 A 8 / " NOTICE: This fireplace is in- tended for use as supplemental  heat. Use this fireplace along with  7 E 9 /8" 3 34 / " your primary heating system. Do F 8 5 Nailing 34 G /8" Nailing Tabs not install this fireplace as your  Tabs 1 primary heat source. If you have a 54 H /8" central heating system, you may  Figure 5 - Framing Clearances for Corner  Installation run system’s circulating blower  while using fi
                    
                    Résumé du contenu de la page N° 7 
                    
                        V G G V A E D V B L OC l a TION OF TERMINaTION Cap N N H C I B Fixed V V Fixed Closed Openable Closed Openable B F V G V J X B B M A V K X V TERMINATION CAP AIR SUPPLY INLET G GAS METER RESTRICTED AREA X (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony I = clearance to service regulator vent outlet [*72 inches (182.9cm)   [*12 inches (30.5mc) minimum]  minimum] B =  clearance to window or door that may be opened J = clearance to non-mechanical air supply inlet
                    
                    Résumé du contenu de la page N° 8 
                    
                        VENTING INSTalla TION   WARNING: Read all instruc- INSTRUCTIONS tions completely and thoroughly  NOTICE: Read these instruc- before attempting installation.  tions completely before at- Failure to do so could result in  tempting installation. serious injury, property damage  or loss of life. These models are tested and approved for use  with DESA (direct-vent) pipe components and  NOTICE: Failure to follow these in- terminations. structions will void the warranty. The venting system must termina
                    
                    Résumé du contenu de la page N° 9 
                    
                        5. Carefully determine the location where the vent  VENTING INSTalla TION  pipe assembly will penetrate the outside wall.  INSTRUCTIONS The center of the hole should line up with the  Continued center-line of the horizontal vent pipe. Mark the  3 3 wall for a 10 /4" x 10 /4" square hole. Cut and  INSTALLATION LANNING p frame the square hole in the exterior wall where  There are two basic types of direct-vent instal- the vent will be terminated. If the wall being  lation: penetrated is constructe
                    
                    Résumé du contenu de la page N° 10 
                    
                        10. Place fireplace into position and shim with  VENTING INSTalla TION  noncombustible material if needed. Nail or  INSTRUCTIONS screw side flanges to framing to secure unit in  Continued place. IMPORTANT: Make sure fireplace is  level before securing. If fireplace is not level  6. Noncombustible Exterior Wall: Position the  1 it will not work properly. horizontal vent cap in the center of the 8 /2"	 round hole and attach to the exterior wall with  four screws (see page 10). Note: The four wood 
                    
                    Résumé du contenu de la page N° 11 
                    
                        VENTING INSTalla TION   WARNING: Never run vent  INSTRUCTIONS downward as this may cause  Continued excessive temperatures which  Siding  could cause a fire. Operation of  Standoff  improperly installed and main- tained venting system could  result in serious injury, property  Minimum Pipe Screws 1 damage or loss of life. Overlap 1 /4"  GROUND FLOOR INSTALLATION Wall  Recommended Applications: Firestop • Installation using cabinet surrounds • Through the wall using round or square termi- nation 
                    
                    Résumé du contenu de la page N° 12 
                    
                        VENTING INSTalla TION INSTRUCTIONS Continued CORNER INSTALLATION Recommended Applications: • Corner ground floor installation • Ground floor installation where pipe vents horizontally through wall (over 12" horizontal pipe) • Basement installation where one foot clearance from ground to termination is possible Not to Exceed  90° Elbow Not to Exceed  Square  (H) Limits (H) Limits Termination Square As Required  90°  Termination for (V), See  Elbow Chart for  Pipe Section  Required Wall 1" Min. F
                    
                    Résumé du contenu de la page N° 13 
                    
                        VENTING INSTalla TION INSTRUCTIONS Continued HORIZONTAL SYSTEM INSTALLATION USING TWO 90° ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system  using two 90° elbows. Venting with Two 90° Elbows    Horizontal (H ) +  1  Vertical (V) Horizontal (H ) Horizontal (H ) 1 2  5' min. ' max. 6' max.  6' min. 4' max. 1' max.   7' min. 6' max. 18' max.  8' min. 8' max. 0' max.  0' max.  8' max. 0' max. 45° Elbow Figure 17 - Horizontal Termination Conf
                    
                    Résumé du contenu de la page N° 14 
                    
                        Flat Ceiling Installation VENTING INSTalla TION  3 1. Cut a 10 /4" square hole in the ceiling using  INSTRUCTIONS the locating hole as a center point. The open- Continued 3 3 ing should be framed to 10 /4" x 10 /4" inside  dimensions, as shown in Figure 9 on page 9  INSTALLATION FOR vERTICAL  using framing lumber the same size as the  TERMINATION ceiling joists. If the area above the ceiling is  Note: Vertical restrictor must be installed in all  an insulated ceiling or an attic, nail firestop  
                    
                    Résumé du contenu de la page N° 15 
                    
                        Venting with One 90° Elbow VENTING INSTalla TION   Vertical (V) Horizontal (H) INSTRUCTIONS  5' min. ' max. Continued  6' min. 4' max.  7' min. 6' max. 6. Continue to add pipe sections until the height   8' min. 8' max. of the vent cap meets the minimum building   0' max. 8' max. code requirements described in Figure 7 on  page 8. Note: You must increase vent height 45° Elbow for steep roof pitches. Nearby trees, adjoining  rooflines, steep pitched roofs and other similar  factors may cause po
                    
                    Résumé du contenu de la page N° 16 
                    
                        When installing this fireplace at an elevation above  VENTING INSTalla TION  4500 feet (in Canada), check with local authorities. INSTRUCTIONS IMPORTANT: For horizontal installations  Continued above 2,000 feet, it is recommended that a 12"  extension pipe be added before starter elbow  (see Figure 25) and a round horizontal termi- nation be used. 45° Starter  Elbow 1"  Extension Vertical Venting V = 40' max. Figure 25 - Recommended 12" Extension  Note: Install  for High Altitude Installation r
                    
                    Résumé du contenu de la page N° 17 
                    
                        VENTING INSTalla TION FIREpla CE  INSTRUCTIONS INSTalla TION Continued CHECK GAS TYPE Number Description Use proper gas type for the fireplace unit you are  VKR-58 Roof Vent Kit, Galvanized   installing. If your gas supply is not correct, do not   (Includes: 45° Elbow, 7"-1"   install fireplace. See retailer where you purchased   Adjustable Pipe, Flue Restrictor,   the fireplace for proper fireplace according to your   Vertical High Wind Termination,   gas type or to purchase gas conversion kit
                    
                    Résumé du contenu de la page N° 18 
                    
                        Speed  FIREpla CE  Switch  Control  Blower  INSTalla TION Bracket Plug-In Continued 3.  Place the blower against the lower rear wall of  the firebox outer wrapper with the exhaust port  directed upward. The blower will fit inside the  back opening and be held in position against  the back wall by the magnets (see Figure 26,  Duplex Outlet  page 17). Control  (Located  Locknut  4.  Be certain that all wire terminals are securely  Shaft  Control underneath  attached to terminals on blower motor an
                    
                    Résumé du contenu de la page N° 19 
                    
                        Power Cord White  FIREpla CE  Blue  Wire Wire INSTalla TION Black  Magnetic  Continued Wire Strips 3.  Place the blower against the lower rear wall of Thermal  Air Flow  Switch the firebox outer wrapper with the exhaust port  Direction directed upward and the thermodisc positioned  up near the fireplace bottom. The thermodisc  must be oriented near the fireplace bottom as  shown in Figure 29, in order to sense tempera- ture and properly operate. The blower will be  Thermal  held in position agai
                    
                    Résumé du contenu de la page N° 20 
                    
                        For propane/LP connection only, the installer must  FIREpla CE  supply an external regulator. The external regula- INSTalla TION tor will reduce incoming gas pressure. You must  Continued reduce incoming gas pressure to between 11" and  14" of water. If you do not reduce incoming gas  INSTALLING GAS pIpING TO  pressure, fireplace regulator damage could occur.  FIRELACE p LOCATION Install external regulator with the vent pointing  down as shown in Figure 31. Pointing the vent   WARNING: A qualifi