Résumé du contenu de la page N° 1 
                    
                         
 
 
 
User’s Manual 
 
5,850 BTU Room Air Conditioner 
Model: SCA062RWB1 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
20060316 
                                                                                                                                                                                                                                                                                                                                                  
                    
                    Résumé du contenu de la page N° 2 
                    
                        Table of Contents Page Introduction 2 Parts Identification 2 Electrical Specifications 4 5 Tips  Before Installation  Installation Instructions 6  9 Operating Instructions Care and Maintenance  13 Troubleshooting Guide 14  1                                                                                                                                                                                                                                                                                    
                    
                    Résumé du contenu de la page N° 3 
                    
                        Introduction Thank you for choosing this room air conditioner to cool your home. This USE AND CARE MANUAL provides  information necessary for the proper care and maintenance of your new room air conditioner.  If properly maintained, your air conditioner will give you many years of trouble free operation. To avoid  installation difficulties, read instructions completely before starting. This manual contains information for the  installation and operation of your room air conditioner. Part Identif
                    
                    Résumé du contenu de la page N° 4 
                    
                          Fan Timer Mode A ir c o n d it io n e r Introduction Part Identification  Remote control model Horizontal Air Vane Interior Air Outlet Vertical Air Vane Fresh Air Lever (for 8K model only) Cabinet Air Filter(Inside) Front Panel Exterior Interior Air  Air Inlet Inlet Grille Remote Control Control Panel Power Cord Control Panel Remote Control Power T i m e r Mode   Power  Saver Mid A u t o Fan Speed High Low _ + Te m p / T i m e   Fan Timer Speed Mode Airconditioner Note: The figures in this man
                    
                    Résumé du contenu de la page N° 5 
                    
                        Electrical specifications 1. All wiring must comply with local and national Electric Shock Hazard ! electrical codes and must be installed by a  licensed electrician.  Once you have any  If the air conditioner has a serial plate rating questions regarding the following instructions,  of 115 volts and up to and including 7.5 amps the unit maybe on a fuse or circuit breaker contact a licensed electrician. with other devices.  However, the maximum  amps of all devices on that fuse or circuit  2. Ch
                    
                    Résumé du contenu de la page N° 6 
                    
                         Tips before installation Your Room Air Conditioner unit is designed to  Your Room Air Conditioner was designed  be highly  efficient and save energy. Follow these for easy installation in a single or double-hung   recommendations for greater efficiency. window. NOTE: This unit is NOT designed for  vertical (slider type) windows.  1. Select thermostat setting that suits your  comfort needs and leave the thermostat at ! CAUTION ! that chosen setting. To avoid installation/operating difficulties, 
                    
                    Résumé du contenu de la page N° 7 
                    
                        Installation instructions F. Your unit was designed to evaporate condensation  ! CAUTION ! under normal conditions.  However, under extreme  Because the compressor is located on the  humidity conditions, excess condensation may cause  controls side of the unit (right side), this side the  base pan to overflow to the outside. will be heavier and more awkward to manipulate. The unit should be installed where condensation Inadequate support on control side of the unit run-off cannot drip on pedestr
                    
                    Résumé du contenu de la page N° 8 
                    
                        Installation instructions Window installation step 1. If your air conditioner cabinet 18'' wide, it will fit  window openings 21'' to 32'' in wide. Minimum  opening height is 14'' from bottom of sash to sill 21'' to 32''  (Fig. 1). Fig. 1 2. Insert the guide panels into the guides of the air  conditioner. Fasten the curtains to the unit with screws (Fig. 2). 2/5 ''  Screws Fig. 2 3. Cut the adhesive-backed seal strip the window width. Remove the backing from the seal strip and attach the seal st
                    
                    Résumé du contenu de la page N° 9 
                    
                        7.5 7.5 T ime r Mode A ir c o n d it io n e r   Fan Installation instructions Inner Sill Outer Sill 5. Install the L brackets on the outer sill with the  Center Line 3/4''  Screw short side of the bracket against the back of the  3/4''  Screw inner sill.  Install one L bracket 7.5 to each side Bracket of center line. See Fig. 5. Short Side 6. Carefully lift the air conditioner and slide it into Fig. 5 the open window.  Make sure the bottom guide of  the air conditioner drops into the notches of 
                    
                    Résumé du contenu de la page N° 10 
                    
                        Operating Instructions Mechanical control model MODE The mode knob controls fan speeds and cooling speeds. To set desired cooling temperature, simply rotate the mode knob dial to the appropriate setting. See Fig. 9. Thermostat knob Mode knob THERMOSTAT The thermostat automatically controls the cooling  cycle (compressor) of the air conditioner to maintain room temperature. However, the fan motor will continue to operate after the compressor (cooling cycle) is completed. See Fig.9.  LOW FAN will 
                    
                    Résumé du contenu de la page N° 11 
                    
                        Operating Instructions  Control Panel You can easily operate this air conditioner by pressing  relevant  Control Panel button  on the control panel as well as the remote control.           Button The air conditioner will be started when it is energized or will be stopped when it is in operation, if you press this button. When the air conditioner is heating, allow  3 minutes after you  press this button. Mode button Each time  Mode button is pressed, the operation mode is changed in sequence: 5K 
                    
                    Résumé du contenu de la page N° 12 
                    
                        Operating Instructions  Remote control           Power BUTTON 1 The appliance will be started when it is energized or will be stopped when it is   in operation, if you press this button. 1 8 Power Timer Mode BUTTON 2 2 9 Mode    Power  Saver Used to select the operation mode.               BUTTONS 7 5 3 Mid Auto Fan Speed Used to set room temperature in COOLING 6 4 mode or used to set  time in Timer mode. High Low _ + 3 High BUTTON 4    Temp/Tim e Used to select the high fan speed  mode. 5 Mid  
                    
                    Résumé du contenu de la page N° 13 
                    
                          Fan r Tim e Mode A ir c o n d it io n e r Operating Instructions  Remote control How to Insert the Batteries Remove the battery cover according to the arrow direction.  Insert new batteries making sure that the (+) and (-) of battery are matched correctly. Reattach the cover by sliding it back into position. Note: Use 2 LR6  AA(1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the display  becomes dim. If the replacement is done within
                    
                    Résumé du contenu de la page N° 14 
                    
                        Care and Maintenance When servicing the air conditioner, be sure to ! ! CAUTION turn the mode switch to the "OFF" position and disconnect the power cord from the electrical outlet. DO NOT forget to install the air filter.  If the air conditioner is left to operate without the air filter, dust is not removed from the room and may 1. DO NOT use  gasoline, benzine, thinner or  cause your air conditioner to fail. other chemicals on the air conditioner as these When the air filter inlet grill and cab
                    
                    Résumé du contenu de la page N° 15 
                    
                        Troubleshooting Guide Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a  possible solution. PROBLEM POSSIBLE CAUSE SUGGESTED SOLUTION Air conditioner will No power to the unit. Check connection of power cord to not operate power source. Check fuse or circuit breaker. Set MODE knob to position other than "OFF". Inefficient or no cooling Dirty air filter. Clean or replace  air filter. Inappropriate capacity Check with dealer to determine p
                    
                    Résumé du contenu de la page N° 16 
                    
                          © 2006 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions.    ® All rights reserved.  Sunbeam is a registered trademark of Sunbeam Products,  Inc. used under license.  Distributed by Petters Consumer Brands, LLC. 4400 Baker  Road, Minnetonka, MN 55343.  For service, support and warranty information, visit www.sunbeammajorappliances.com or in the US call 1-866-866-6283.