WINEMATE Split System 
 
Installation, Operation & Care Manual 
 
 
WM1500 SSW 
WM2500 SSW 
 
 
Vinotemp International Corp. 
Vinotemp International Corp. 
 
 
www.vinotemp.com 
www.vinotemp.com                                                                                                                                                                                                                                                                                                              
                    
                    Résumé du contenu de la page N° 2 
                    
                              TABLE OF CONTENTS      Important Safety Information…..........................................2     Feature Description…………………………….……………..3    Installation Instruction………………………………………..5    Use and Temperature Control……………………………….7    Care Guide……………………………………………………10               Troubleshooting……………………………………………..11    Customer Support……………………………………………13    Warranty……………………………………………………….14                                                                                                      
                    
                    Résumé du contenu de la page N° 3 
                    
                        Important Safety Information            • DO NOT USE A GROUND FAULT INTERRUPTER (GFI).  • A DEDICATED 20 AMPCIRCUIT IS HIGHLY RECOMMENDED.                                                                      - 2 -                                                                                                                                                                                                                                                                                               
                    
                    Résumé du contenu de la page N° 4 
                    
                        Feature Description      • WineMate split cooling system is designed and used to provide a stable  temperature between 52~62 °F for suitable space at a normal  environment.   • The refrigerated space will maintain humidity of 50~70% RH even when  the environment becomes dry and humid.  • These temperatures and humilities are optimized for long term storage of  wine, fur and tobacco.   • SSW units are designed for installation between two wall studs,   making  them an ideal choice for small and m
                    
                    Résumé du contenu de la page N° 5 
                    
                          Evaporator Unit            Condensing Unit                                                                      - 4 -                                                                                                                                                                                                                                                                                                                                                                                             
                    
                    Résumé du contenu de la page N° 6 
                    
                        Installation Instruction      Federal law requires that WINEMATE split cooling systems be  installed by an EPA certified refrigeration technician.    1. Location    • Place the condensing unit in a properly ventilated location. If it is not, heat  exhausted by the condensing unit will build up and the cooling system will  not operate properly.   • Leave minimum 3 feet clearance between the exhaust side and the wall.  • Leave minimum 1 foot clearance for the fresh air supply side.  • Condensing u
                    
                    Résumé du contenu de la page N° 7 
                    
                        The condensing unit and unit cooler are connected by a liquid line and an  insulated suction line that are supplied by the installer. These lines must be  properly sized for the distance between the two units. After the units and the lines  are installed, the system must be pressure tested. If no leaks are found,  evacuate and charge system with R134A. Refrigerant amount will vary  depending on the length of line set.    3. Electrical Wiring    • We strongly recommend against the use of an exten
                    
                    Résumé du contenu de la page N° 8 
                    
                        Use & Temperature Control      1. Temperature Setting    • Set the temperature at 55 °F for the optimum aging of wine  • Set the temperature higher at very high ambient temperature.  • On initial start-up, the time required to reach the desired temperature  will vary, depending on the quantity of bottles, temperature setting  and surrounding temperature.  • Allow 24 hours to stabilize the temperature for each new temperature  setting operation    2. Use of the controller            1) Display  D
                    
                    Résumé du contenu de la page N° 9 
                    
                        1.2 Front Panel Commands      2) Alarm Signals  2.1 Code Description        2.2 Alarm Recovery   Probe alarms P1”, start a few seconds after the fault in the related probe; they  automatically stop a few seconds after the probe restarts normal operation.  Check connections before replacing the probe. Temperature alarms “HA”, “LA”  automatically stop as soon as the temperature returns to normal value. Alarm  “CA” (with i1F=PAL) recovers only by switching off and on the instrument.     3) Set-Poin
                    
                    Résumé du contenu de la page N° 10 
                    
                        1. Push the SET key for more than 3 seconds to change the Set point value;   2. The value of the set point will be displayed and the “°C” or “°F” LED starts  blinking;   3. To change the Set value, push the o or n arrows within 10s.   4. To memorize the new set point value, push the SET key again or wait 10s.    4) Manual Defrost  Push the DEF key for more than 2 seconds and a manual defrost will start.                                                                                              
                    
                    Résumé du contenu de la page N° 11 
                    
                        Care Guide         In general, always unplug system or disconnect power while doing care.    1. Coil Cleaning    • Clean the condenser coil regularly. Coil may need to be cleaned at  least every 6 months.  • Unplug the system or disconnect power.  • Use a vacuum cleaner with an extended attachment to clean the coil  when it is dusty or dirty.  • Plug cooling system or reconnect power.    2. Moisture Removing    • Remove the extra condensate if it is accumulated in the wine cellar at  high ambien
                    
                    Résumé du contenu de la page N° 12 
                    
                        Troubleshooting    This Troubleshooting Chart is not prepared to replace the training required for a  professional refrigeration service person, not is it comprehensive    Troubleshooting Chart  Complaint Possible Causes Response  1. Unit not running   a. Power cord unplugged a. Check for power cord plug  b. No power to unit b. Check power at receptacle & fuses  c. Temperature setting high c. Lower temperature setting  d. Low voltage. d. Contact an authorized electrician   e. Incorrect or loose 
                    
                    Résumé du contenu de la page N° 13 
                    
                        g. Low voltage g. Check power supply  h. Operating 60 Hz unit at 50Hz h. Use proper 60 Hz  i. Sealed system problem i. Call service for checking loss of   refrigerant or restrictions  j. Undercharge or overcharge j. Call service to add or remove   refrigerant    7. House circuit tripping  a. Incorrect fuse or breaker  a. Check for proper fuse or breaker    b. Incorrect wirings b. Check for wirings and connections  c. Failed components c. Call service      8. Noisy operation  a. Mounting area not
                    
                    Résumé du contenu de la page N° 14 
                    
                        Customer Support      If you still have problems, please contact us at:      Vinotemp International   17631 South Susana Road   Rancho Dominguez, CA 90221   Tel:  (310) 886-3332   Fax: (310) 886-3310   Email: info@vinotemp.com                                                                                                                        - 13 -                                                                                                                                                    
                    
                    Résumé du contenu de la page N° 15 
                    
                        Warranty       Thank you for choosing a Vinotemp wine cellar.    Please enter the complete model and serial numbers in the space provided:    Model_________________________________________________________  Serial No.______________________________________________________    Attach your purchase receipt to this owner’s manual.      1.  Limited Warranty              VINOTEMP warrants its products, parts only, to be free from defects due to  workmanship or materials under normal use and service for 
                    
                    Résumé du contenu de la page N° 16 
                    
                        VINOTEMP will, at its discretion, repair or replace the unit and return it free of  charge to the original retail customer. If the unit is found to be in good working  order, or beyond the initial twelve month period, it will be returned freight collect.      2. Limitation of Implied Warranty    VINOTEMP’S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED  TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT.    VINOTEMP SHALL NOT BE LIABLE FOR:  DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN