ページ1に含まれる内容の要旨
INSTALLATION MANUAL FOR TFP AIR CLEANER
TFP2000 (Wholehouse Model)
TFPC2000 (Portable Console Model)
Materials Supplied
ATTENTION
1 TFP
The furnace fan and/or HRV must operate
4 mounting brackets
continuously for Type 1 and Type 2 installations.
4 hanging straps
If they do not operate continuously, then
2 oval collar connections
interlocking them electrically with the TFP is
4 8/32” X 3/4” sheet metal screws
acceptable. Consult a certified electrician.
8 8/32” X 3/8” sheet metal
ページ2に含まれる内容の要旨
TYPE 1 INSTALLATION TFP Directly Connected to Forced Air Heating System NOTE: Do not support the weight of the TFP on 1. Install 6” oval port collar (provided) on top and the duct. Duct must be open and not pinched. bottom of TFP (Fig. 1). Use (4) 8/32” X 3/8” screws (provided). NOTE: Due to possible noise transfer through the duct system, it may be preferable in some 2. Remove protective backing from pieces of situations to hang the TFP a short distance from the plenum, and connect by runni
ページ3に含まれる内容の要旨
TYPE 2 INSTALLATION TFP Connected to Heat Recovery Ventilator Type 2 Installation LOCATION * “Breathing T” is designed to assist in neutralizing The TFP should be located in the main trunk of pressure differences which can occur between HRV the fresh air to house line, after the Heat and TFP when joined together. Recovery Ventilator (HRV) and before any branch lines. (Fig. 3) MOUNTING FLOOR JOISTS 1. Locate mounting bolts (4) on side of TFP cabinet for vertical hanging (Fig. 3) and remove.
ページ4に含まれる内容の要旨
TYPE 3 INSTALLATION Type 3 Installation TFP Independent Installation No HRV, Radiant Heating System LOCATION 1. A TFP is usually installed in a basement area where air flow noise will be negligible to the occu- Return Grille pants. Clean air supply High wall 2. A central location between the clean air supply or floor grille grille and return grille is recommended. optional High wall MOUNTING or floor grille 1st or 2nd optional Refer to “Mounting” under Type 2 Installations. STORY FLOOR JOIST