ページ1に含まれる内容の要旨
ERO28C*B ERO28RAC*B
Installation/Care/Use Manual
®
Soft Sides Refrigerated Fountains with FLEXI-GUARD
13
SEE FIG. 7
42
14
42
ERO28C ERO28RAC
Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORME
ページ2に含まれる内容の要旨
ERO28C*B ER028RAC*B 97114C (Rev. F - 01/01) PAGE 2 ERO28C ERO28RAC LEGEND A = 3/8" O.D. TUBE CONNECT (CHILLER WATER OUTLET) B = 3/8" O.D. TUBE CONNECT (CHILLER WATER INLET) SHUT OFF VALVE BY OTHERS C = 1-1/4" TRAP FURNISHED FIG. 3 D = ELECTRICAL INLET
ページ3に含まれる内容の要旨
ERO28C*B ERO28RAC*B INSTALLATION INSTRUCTIONS 1. Install mounting frame. See mounting frame instructions. 2. Install remote chiller. Remove front panel of chiller. Slide chiller onto the shelf and position it to the left within the guides on the shelf. 3. Attach solenoid valve assy to the underside of cross member of mounting frame on electric eye unit. See Figure 9. 4. Make water supply connections. Install a shut-off valve and union connection to building water supply (valve and union
ページ4に含まれる内容の要旨
ERO28C*B ER028RAC*B PARTS LIST TROUBLE SHOOTING AND MAINTENANCE ITEM NO. P ART NO. DESCRIPTION 1. Orifice Assy: Minerals deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round 1 A54874 Orifice Assy 2 50934C Housing Assy file not over 1/8" diameter or a small diameter wire. CAUTION: Do not file or cut orifice materials. 3 50168C Pedestal 4 70012C Bubbler Locknut 2. Stream Regulator: If orifice is fr