ページ1に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15
Page  of 8   2 Light T5 HO Semi-Indirect
Weight = 3.0 lb./ft
Ordering Information
Family Distribution Lamp Type No. of Lamps Housing Module Length Wiring Voltage Ballast Finish
BSL 5 H 02 LN           
02 = 2 Light C = Custom Color
5 = Semi-Indirect H = T5 HO LN = Perforated 04 = 4’
1 = cct.  D = Dual 20V   E = Standard  
W = Standard
08 = 8’
2 = 2cct. & 277V <0%  THD
   White
12 = 2’
3 = cct. w/EC/NL 1 = 20V  F = Standard  
4 = 2cct. w/EC/NL 2 = 277V <0%
                    
                    ページ2に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15 Page 2 of 8   2 Light T5 HO Semi-Indirect Performance COEFFICIENTS OF UTILIZATION COEFFICIENTS OF UTILIZATION Candlepower Curve Candlepower Summary Coefficients of Utilization Candlepower Summary   ZONE CANDLEPOWER  % EFFECTIVE CEILING CAVITY REFLECTANCE % EFFECTIVE CEILING CAVITY REFLECTANCE  DEG. 0 22.5 45 67.5 90 80 70 50 80 70 50  180 2038 2038 2038 2038 2038 % WALL REFLECTANCE % WALL REFLECTANCE  175 2026 2027 2031 2036 2039 50 30 10 50 30 10 50 30 10 50 30 1
                    
                    ページ3に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15 Page 3 of 8   2 Light T5 HO Semi-Indirect Mounting Options Mount Type: T-Bar 15/16” (On-Grid)* 1-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’   3 Conductor BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13   4 Conductor BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14   7 Conductor BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17 •   65 lbs maximum load •   Canopy: Diameter of 3 3/4“x 7/32” BSLM6102N BSLM6104N BSLM6108N BSLM6112N Non-Power M
                    
                    ページ4に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15 Page 4 of 8   2 Light T5 HO Semi-Indirect Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’   3 Conductor BSLM2102P13 BSLM2104P13 BSLM2108P13 BSLM2112P13   4 Conductor BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14 •   Meets UBC, OSHPD and DSA seismic requirements  2-Power Mount •   Canopy: Diameter of 5 /4“x 3/4” (power)  BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23 
                    
                    ページ5に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15 Page 5 of 8   2 Light T5 HO Semi-Indirect Mount Type: Non-Accessible Ceilings (concrete, gypsum etc.) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’   3 Conductor BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13   4 Conductor BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14 •   Meets UBC, OSHPD and DSA seismic requirements   7 Conductor BSLM1102P17 BSLM1104P17 BSLM1108P17 BSLM1112P17 /4  3/4 •   Canopy: Diameter of 5 “x ” (p
                    
                    ページ6に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15 Page 6 of 8   2 Light T5 HO Semi-Indirect Wiring Options: 1 Circuit 1 Circuit Type 1: cct.    Type 8: cct. w/cct.  thru wire    Type H: cct. w/2cct. thru wire Type 7: cct. w/dimming All lamps wired on one circuit. 1 Circuit with Emergency Circuit/Night Light (EC/NL) Type 3: cct.  w/EC/NL       One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal  circuit and EC/NL circuit wired to fixture ends. All lamps in EC
                    
                    ページ7に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15 Page 7 of 8   2 Light T5 HO Semi-Indirect Wiring Options: 2 Circuit Left/Right Switching 2 Circuit Left/Right Switching Type 2: 2cct.    Type 9: 2cct. w/cct.  thru wire    Type I: 2cct. w/2cct. thru wire Fixture wired for two circuit. Lamps wired for left/right switching. 2 Circuit Left/Right Switching with Emergency Circuit/Night Light (EC/NL) Type 4: 2cct. w/EC/NL        One 4’ section in two circuit fixture (left/right switching) to be wired on a separate thru
                    
                    ページ8に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL15 Page 8 of 8   2 Light T5 HO Semi-Indirect Wiring Options: 2 Circuit A/B Switching (alternate 4’ sections) 2 Circuit A/B Switching (alternate 4’ sections)  Type B: 2cct. A/B    Type A: 2cct. A/B w/cct. thru wire    Type S: 2cct. A/B w/2cct. thru wire Fixture wired for two circuit. Lamps wired for A/B switching in alternate 4’ sections. 2 Circuit A/B Switching (alternate 4’ sections) with Emergency Circuit/Night Light (EC/NL) Type C: 2cct. w/EC/NL       One 4’ sect