ページ1に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13
Page  of 8   4 Light T8 Semi-Indirect
Weight = 3.0 lb./ft
Ordering Information
Family Distribution Lamp Type No. of Lamps Housing Module Length Wiring Voltage Ballast Finish
BSL 5 T 04 LN           
5 = Semi-Indirect T = T8 04 = 4 Light LN = Perforated 1 1  = = 20V 20V 
04 = 4’ C = Custom Color
1 1  = = cct. cct. E E = = Standard Standard   
2 2  = = 277V 277V 
08 = 8’ W = Standard
2 2  = = 2cct. 2cct. <20% <20% THD THD
12 = 2’   White
3 3 = = cct. cct. 
                    
                    ページ2に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13 Page 2 of 8   4 Light T8 Semi-Indirect Performance COEFFICIENTS OF UTILIZATION COEFFICIENTS OF UTILIZATION Candlepower Curve Candlepower Summary Coefficients of Utilization Candlepower Summary   % EFFECTIVE CEILING CAVITY REFLECTANCE  ZONE CANDLEPOWER % EFFECTIVE CEILING CAVITY REFLECTANCE  80 70 50 DEG. 0 22.5 45 67.5 90 80 70 50  % WALL REFLECTANCE 180 2754 2754 2754 2754 2754 % WALL REFLECTANCE  175 2741 2743 2747 2747 2749 50 30 50 30 10 10 50 5030 30 10 10 50
                    
                    ページ3に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13 Page 3 of 8   4 Light T8 Semi-Indirect Mounting Options Mount Type: T-Bar 15/16” (On-Grid)* 1-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’   3 Conductor BSLM6102P13 BSLM6104P13 BSLM6108P13 BSLM6112P13   4 Conductor BSLM6102P14 BSLM6104P14 BSLM6108P14 BSLM6112P14   7 Conductor BSLM6102P17 BSLM6104P17 BSLM6108P17 BSLM6112P17 •   65 lbs maximum load •   Canopy: Diameter of 3 3/4“x 7/32” BSLM6102N BSLM6104N BSLM6108N BSLM6112N Non-Power Moun
                    
                    ページ4に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13 Page 4 of 8   4 Light T8 Semi-Indirect Mount Type: T-Bar Fixed Position (1/4-20 Threaded Rod) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’   3 Conductor BSLM2102P13 BSLM2104P13 BSLM2108P13 BSLM2112P13   4 Conductor BSLM2102P14 BSLM2104P14 BSLM2108P14 BSLM2112P14 •   Meets UBC, OSHPD and DSA seismic requirements  2-Power Mount •   Canopy: Diameter of 5 /4“x 3/4” (power)  BSLM2102P23 BSLM2104P23 BSLM2108P23 BSLM2112P23   3
                    
                    ページ5に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13 Page 5 of 8   4 Light T8 Semi-Indirect Mount Type: Non-Accessible Ceilings (concrete, gypsum etc.) 1-Power Mount 2-Power Mount Non-Power Mount Supension Length 1-Power Mount 2’ 4’ 8’ 12’   3 Conductor BSLM1102P13 BSLM1104P13 BSLM1108P13 BSLM1112P13   4 Conductor BSLM1102P14 BSLM1104P14 BSLM1108P14 BSLM1112P14 •   Meets UBC, OSHPD and DSA seismic requirements   7 Conductor BSLM1102P17 BSLM1104P17 BSLM1108P17 BSLM1112P17 /4  3/4 •   Canopy: Diameter of 5 “x ” (powe
                    
                    ページ6に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13 Page 6 of 8   4 Light T8 Semi-Indirect Wiring Options: 1 Circuit 1 Circuit    Type 1: cct.    Type 8: cct.  w/cct.  thru wire    Type H: cct. w/2cct. thru wire    Type 7: cct.  w/dimming All lamps wired on one circuit. 1 Circuit with Emergency Circuit/Night Light (EC/NL) Type 3: cct. w/EC/NL               One 4’ section in a one circuit fixture to be wired on a separate thru circuit. Leads for both normal  circuit and EC/NL circuit wired to fixture ends. All
                    
                    ページ7に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13 Page 7 of 8   4 Light T8 Semi-Indirect Wiring Options: 2 Circuit Center/Outer Switching 2 Circuit Center/Outer Switching Type 2: 2cct.       Type 9: 2cct. w/cct.  thru wire    Type I: 2cct. w/2cct. thru wire    Fixture wired for two circuit. Lamps wired for center/outer switching. 2 Circuit Center/Outer Switching with Emergency Circuit/Night Light (EC/NL) Type 4: 2cct. w/EC/NL             One 4’ section in two circuit fixture (center/outer switching) to be wired 
                    
                    ページ8に含まれる内容の要旨 
                    
                        Lighting Systems Baselyte-BSL13 Page 8 of 8   4 Light T8 Semi-Indirect Wiring Options: 2 Circuit A/B Switching (alternate 4’ sections) 2 Circuit A/B Switching (alternate 4’ sections)  Type B: 2cct.       Type A: 2cct. w/cct.  thru wire    Type S: 2cct. w/2cct. thru wire    Fixture wired for two circuit. Lamps wired for A/B switching in alternate 4’ sections. 2 Circuit A/B Switching (alternate 4’ sections) with Emergency Circuit/Night Light (EC/NL) Type C: 2cct. w/EC/NL             One 4’ sectio