                        Installation and Assembly:
Model: DS508
Maximum Load Capacity: 
200 lb (90.7 kg)
ISSUED: 03-05-09  SHEET #:125-9054-2   07-15-09
Visit the Peerless Web Site at www.peerlessmounts.com            For customer care call 1-800-865-2112 or 708-865-8870.                                                                                                                                                                                                                                                            
                    
                    ページ2に含まれる内容の要旨 
                    
                         IMPORTANT! Read instruction sheet before you start installation and assembly. WARNING •	 Do	not	begin	to	install	your	Peerless	product	until	you	have	read	and	understood	the	instructions	and	warnings	 contained	in	this	Installation	Sheet.	If	you	have	any	questions	regarding	any	of	the	instructions	or	warnings,	for	US	 customers 	please	call	Peerless	customer	care	at	1-800-865-21 12,	for	all	international	customers,	please	contact	 your	local	distributor . •	 This	product	should	only	be	installe
                    
                    ページ3に含まれる内容の要旨 
                    
                        Before you begin, make sure all parts shown are included with your product.  Parts may appear slightly different than illustrated.  A Parts List Description Qty. Part # A wall plate 1 145-1054 B adapter plate 1 145-1052 C #14	x	2.5"	wood	screw 4 5S1-015-C03 D concrete anchor 4 590-0097 E M8	x	15	mm	socket	pin	screw 4 520-1068 F M4	x	12	mm	phillips	screw 4 504-9013 G M5	x	12	mm	phillips	screw 4 520-1027 H M6	x	12	mm	phillips	screw 4 520-1128 I M10	x	15	mm	socket	screw 4 520-9262 J #8	SAe	flat	was
                    
                    ページ4に含まれる内容の要旨 
                    
                        Installation to Double Wood Stud Wall WARNING •	 Installer 	must	verify	that 	the	supporting	surface	will	safely	support	the	combined	load	of	the	equipment	and	all	 attached hardware and components. •	 T ighten	wood	screws	so	that 	wall	plate	is	firmly	attached, 	but	do	not	overtighten.	Overtightening	can	damage	the	 screws,	greatly 	reducing	their	holding	power . •	 Never	tighten	in	excess	of	80	in.	•	lb	(9	N.M.). •	 Make	sure	that	mounting	screws	are	anchored	into	the	center	of	the	stud.	 The	
                    
                    ページ5に含まれる内容の要旨 
                    
                        Installation to Solid Concrete or Cinder Block WARNING •	 When 	installing	Peerless	wall	mounts	on	cinder	block,	verify	that	you	have	a	minimum	of	1-3/8"	of	actual	concrete	 thickness	in	the	hole	to	be	used 	for	the	concrete	anchors.	Do	not	drill	into	mortar	joints!	Be	sure	to	mount	in	a	solid	 part	of	the	block,	generally	1"	minimum	from	the	side	of	the	block.	Cinder	block	must	meet	 ASTM	C-90	specifica- tions. 	It	is	suggested 	that	a	standard	electric	drill	on	slow	setting	is	used	to	drill	th
                    
                    ページ6に含まれる内容の要旨 
                    
                        Installation to Metal Studs WARNING •	 Drywall 	must	be	1/2"	or	thicker ,	and 	metal	stud	must	be	24	gauge	or	thicker . •	 Make	sure	that	the	wall	will	safely	support 	the	combined	load	of	the	equipment	and	all	attached 	hardware	and	 components. •	 Make	sure	that	togglers	are	anchored 	into	the	center	of	the	studs.	 The	use	of	an	"edge	to	edge"	stud	finder	is	highly	 recommended. Using	a	stud	finder ,	locate 	and	mark	the	edges	of	the	metal	stud	used	in	mounting	this	product.	Use	of	an	edge	 1 
                    
                    ページ7に含まれる内容の要旨 
                    
                        Placement of Adhesive Strips Place adhesive strips (K) on the wall plate (A) in location that will allow the most contact with CPU. 2 Note: 	Placement 	of	adhesive 	strips	will	vary	depending	on	size	of	CPU	as	shown	in	figure	2.2 fig.	2.1 fig.	2.2 A Placement	of	adhesive	 Placement	of	adhesive	 strips (K)	for	smaller	CPU's strips (K)	for	larger	CPU's K Attach CPU to Wall Plate NOTE:	Safety	belt	may	need	to	be	loosened	to	attach	CPU	to	wall	plate	(A).  3 Press	CPU	against	adhesive 	strips	on	wall
                    
                    ページ8に含まれる内容の要旨 
                    
                        Attaching	 Adapter	Plate 	to	Screen fig.	4.1 Attaching	adapter	plate	to	screen 	with	  SCreeN 4 VESA hole pattern: Choose	hole	pattern	and	fasteners	shown	in	detail	2	for	 B mounting screen with VESA mounting patterns. Hand thread  screws (F, G or H) through washers (J or O) and adapter  plate (B)	into	screen	as	shown 	in	figure	4.1.	Screw	must	 make	at	least	three 	full	turns	into	the	mounting	hole	and	fit	 snug	into	place.	Securely	tighten	screws. WARNING •	 If	screws	don't	get	three 	complete
                    
                    ページ9に含まれる内容の要旨 
                    
                        Attaching	 Adapter	Plate 	to	W all	Plate Thread	two	M8	x	15	mm	screws	(E)	into	bottom	holes	of	wall	plate	(A)	leaving	1/8"	space	between	head	of	screw	 5 and	wall	plate	as	shown 	in	figure	5.1. 	guide	hook	slots	of	adapter	plate	( B) onto screws (E),	while	supporting	 weight 	of	screen,	align	top	holes	of	wall	plate	and	adapter	bracket	to	the	desired	tilt	angle	and	secure	with	two	M8	x	 15 mm screws (E).	 T ighten	all	screws	securely . fig.	5.1 10° TILT 5° TILT fig.	5.2 NO	 TIL T A HOOK	 SLOTS E