ページ1に含まれる内容の要旨 
                    
                        QUICK START GUIDE
Cisco ASR 1006 Router
1 Documentation and Resources
2 Prepare for Installation
3 Rack-Mount the Router
4 Connect the Router to the Network
5 Start the System
6 Configure the Router
7 After Installation                                                                                                                                                                                                                                                                                         
                    
                    ページ2に含まれる内容の要旨 
                    
                        1  Documentation and Resources Documentation for the Cisco ASR 1000 Series Aggregation Services Routers documentation is online with the exception of the  regulatory compliance and safety documentation and the Cisco ASR 1000 Series Aggregation Services Routers documentation  flyer. Refer to the following documentation for installation and replacement of parts (including shared port adapters) and  regulatory compliance information. • Shared port adapter documentation—See the Cisco ASR 1000 Series
                    
                    ページ3に含まれる内容の要旨 
                    
                        2  Prepare for Installation This section contains information about tools and parts, warnings, site preparation information, and information for  rack-mount installation and equipment shelf or tabletop installation. Warning Only trained and qualified personnel should install, replace, or service this equipment. Statement 1030 Before beginning this router installation, read the Regulatory Compliance and Safety Information for the Cisco ASR 1000 Series  Aggregation Services Routers document. Site 
                    
                    ページ4に含まれる内容の要旨 
                    
                        Cisco ASR 1006 2 1 F1 F0 R1 R0 Prepare for Rack-Mount Installation Before you begin the rack-mounting tasks:  Decide whether or not you want to front rack-mount or rear rack-mount the chassis  Decide whether or not you want to attach cable-management brackets to your chassis.  Note If you install cable-management brackets, make certain that the chassis is installed in the equipment rack first.  Decide if a two-post or four-post rack-mount will be used.  3  Rack-Mount the Router This section p
                    
                    ページ5に含まれる内容の要旨 
                    
                        Cisco ASR 1006 ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 22 2 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 11 1 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 00 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS PWR ACTV STAT STBY F1 ASR1000-ESP10 F1 PWR ACTV STAT STBY F0 F0 ASR1000-ESP10 CRIT HD PWR ACTV MAJ USB STAT STBY MIN BF CARRIER LINK ASR1000-RP1 0 1 DISK BITS MGMT ETHERNET CON AUX R R11 R1 CRIT HD PWR ACTV MAJ USB STAT STBY MIN 
                    
                    ページ6に含まれる内容の要旨 
                    
                        1 1 0 0 Figure 3 Cisco ASR 1006 Router Rear Rack-Mounting 1 2 3 4 Rear rack-mount bracket attached to the chassis Components that slide into the mounted bracket 1 3 2 Rear rack-mount bracket component 4 Rear rack-mount bracket screw Step 3 Insert and tighten the five screws. After the bracket is secured to the side of the chassis, slide the two remaining  components (item 3, Figure 3) into the side rack-mount bracket. Step 4 Repeat Step 1 through Step 3 on the other side of the chassis. Use five
                    
                    ページ7に含まれる内容の要旨 
                    
                        Cisco ASR 1006 ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 2 2 2 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 1 1 1 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 00 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS PWR ACTV STAT STBY F1 ASR1000-ESP10 F1 PWR ACTV STAT STBY F0 F0 ASR1000-ESP10 CRIT HD PWR ACTV MAJ USB STAT STBY MIN BF CARRIER LINK ASR1000-RP1 0 1 DISK BITS MGMT ETHERNET CON AUX RR11 R1 CRIT HD PWR ACTV MAJ USB STAT STBY MIN
                    
                    ページ8に含まれる内容の要旨 
                    
                        Step 7 Align the mounting bracket holes with the rack post holes and attach the chassis to the rack. At this point, if there is a  third person, then that person can insert the screws while the other two people hold that chassis in place, unless the  chassis is resting on a shelf). Step 8 Position the chassis until the rack-mounting ears are flush against the mounting rails on the rack. Step 9 Hold the chassis in position against the mounting rails and follow these steps: a. Insert the bottom sc
                    
                    ページ9に含まれる内容の要旨 
                    
                        Cisco ASR 1006 ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 2 2 2 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS ASR1000-SIP10 -4 OC3- O SPA-4XOC3-POS SPA X P S 11 1 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS ASR1000-SIP10 SPA-4XOC3-POS SPA-4XOC3-POS 00 SPA-4XOC3-POS SPA-4XOC3-POS PWR STATUS PWR ACTV STAT STBY F1 ASR1000-ESP10 F1 PWR ACTV STAT STBY F0 F0 ASR1000-ESP10 CRIT HD PWR ACTV MAJ USB STAT STBY MIN BF CARRIER LINK ASR1000-RP1 0 1 DISK BITSC MGMT ETHERNET ON AUX R1 R1 R1 CRIT HD PWR ACTV MAJ USB STAT ST
                    
                    ページ10に含まれる内容の要旨 
                    
                        Note As a result of using the specified rack-mount bracket ear holes, the cable-management bracket can be easily  attached to the rack-mount bracket when the chassis is in the rack. This completes the procedure for installing the chassis in a two-post rack. Proceed to the “Attach the Cable-Management  Bracket” section on page 10 to continue the installation. Attach the Cable-Management Bracket The cable-management brackets mount to each rack-mount bracket on the chassis to provide cable-manageme
                    
                    ページ11に含まれる内容の要旨 
                    
                        Figure 6 Attaching the Cable-Management Bracket to the Cisco ASR 1006 Router 1 3 2 1 Cable-management bracket screw location Chassis front rack-mount bracket and ear holes 1 3 2 Cable-management bracket Step 3 Using the bottom rack-mount ear hole, insert the screw through cable-management bracket and into the chassis  rack-mount bracket (see Figure 6).  Step 4 Using a Phillips screwdriver and the cable-management screw, thread and tighten the screw to the cable-management  bracket. Step 5 Repeat
                    
                    ページ12に含まれる内容の要旨 
                    
                        Chassis Ground Connection Installation Before you connect power or turn on power to your router, you must provide an adequate chassis ground (earth) connection  for the router chassis. A ground connector is provided on each Cisco ASR 1006 Router. See Figure 7. Caution The dual-lug chassis stud must be installed, the SIP and SPA must be fully inserted and screwed in and earthed to  prevent a potential hazard in a telecom line.  Have the recommended tools and supplies available before you begin th
                    
                    ページ13に含まれる内容の要旨 
                    
                        Step 8 Connect the opposite end of the grounding wire to the appropriate grounding point at your site to ensure an adequate  chassis ground. This completes the procedure for attaching a chassis ground connection. Go to the “Connect the Router to the Network” section  on page 13 for information on attaching cables. 4  Connect the Router to the Network This section provides information about cables and ports and attaching the router to the network.  Console and Auxiliary Port Cable Connections, p
                    
                    ページ14に含まれる内容の要旨 
                    
                        – Connect to the port using the RJ-45-to-RJ-45 cable and RJ-45-to-DB-25 DTE adapter or using the  RJ-45-to-DB-9 DTE adapter. Figure 8 Management Ethernet Port Connectors 4 3 2 1 1 AUXiliary connection 3 BITS port 2 MGMT Ethernet port 4 Cable-management U feature device Step 3 Insert an Ethernet RJ-45 cable into the MGMT ETHERNET port. Step 4 Insert the other end of the RJ-45 cable to your management device or network. Step 5 Configure to a fixed speed through the command line interface (CLI) com
                    
                    ページ15に含まれる内容の要旨 
                    
                        100-240V~ 16-7A 50-60HZ it mi This un ght have more than one power supply connection. All connections must be removed to de-energize the unit. Install the Cables in the Cable-Management Bracket No specific card level cable-management will be provided on the SIP carrier cards. SPAs utilize the SPA cable-management  brackets that are provided with each SPA as part of their accessory kits. Cables coming off the front side of the SPAs and SIPs  utilize the chassis level cable-management brackets pro
                    
                    ページ16に含まれる内容の要旨 
                    
                        Step 2 Plug the power cable into the inlet. Note For additional AC power cable strain relief, secure the cable to the power supply handle by inserting a nylon cable tie  through the hole in the handle and around the cable. Figure 10 Cisco ASR 1006 Series Router AC Power Supply  6 7 8 OUTPUT INPUT INPUT FAIL OK OK ALARMS 60V 1A MAX 100-240V~ 16-7A 50-60HZ 5 This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 4 3 2 1 1 AC power suppl
                    
                    ページ17に含まれる内容の要旨 
                    
                        OFF Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of  a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if  you are uncertain that suitable grounding is available. Statement 1024 Warning This unit might have more than one power supply connection. All connections must be removed to de-energize the  unit. Statement 1028 Warning This product relies on the building’s in
                    
                    ページ18に含まれる内容の要旨 
                    
                        Note DC input power cables must be connected to the PDU terminal studs in the proper positive (+) and negative (–) polarity.  In some cases, the DC cable leads are labeled, which is a relatively safe indication of the polarity. However, you must  verify the polarity by measuring the voltage between the DC cable leads. When making the measurement, the positive  (+) lead and the negative (–) lead must always match the (+) and (–) labels on the power distribution unit.   An earth ground cable is r
                    
                    ページ19に含まれる内容の要旨 
                    
                        OFF Figure 13 DC Power Supply Ground Studs and Cables 1 2 -48/-60V         40A This unit might have more than one power supply connection. All connections must be removed to de-energ 4 3 1 Negative lug and wire with sleeving wrapped around the 3 Location of sleeving wrapped around the wire and end of  wire and end of lug the grounding stud 2 Positive lug and wire with sleeving wrapped around the 4 Earth ground lug and wire wire and end of lug Step 4 Ground the other end of the grounding wires to
                    
                    ページ20に含まれる内容の要旨 
                    
                        OFF 55 -48/-60V         40A This unit might have more than one power supply connection. All connections must be remov Figure 14 DC Power Supply Terminal Block 1 2 4 3 DC power supply terminal block negative stud Terminal block slotted keyed area 1 3 2 DC power supply terminal block positive stud 4 DC power supply terminal block plastic cover Caution Before you continue to install the terminal block ground wires, stop and perform Step 5. To prevent any contact  with metal lead on the ground wire