ページ1に含まれる内容の要旨
KIT63000
Replacement Power Supply Kit for
TM
GAPAB Infinity Air Purifier
Installation Instructions
NOTE: Read the entire instruction manual before starting the install.
SAFETY CONSIDERATIONS:
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions
which may cause personal injury or property damage.
Follow all safety codes. Wear safety glasses and work gloves. Have a fire extinguisher available. Read these i
ページ2に含まれる内容の要旨
REMOVING THE OLD POWER SUPPLY: TM 1: Turn off power to the heating and cooling system and to the Infinity air CAUTION purifier. CUT HAZARD 2: Remove the air purifier door (Fig. 1). Disconnect the power cord and air Failure to follow this caution may result in personal flow sensor cables from the power supply module (Fig. 2). injury. Sheet metal parts may have sharp edges or 3: Remove the filter and enhancement module from the air purifier cabinet burrs. Use care and wear appropriate prot
ページ3に含まれる内容の要旨
8: Remove the power supply module from the enhancement module by unscrewing the four Phillips head screws (Fig. 9). You are now ready to install the new power supply. INSTALLING THE NEW POWER SUPPLY: 1: Strip the red and black replacement power supply wires ¼” from ends. 2: Insert the high voltage wires through the holes in the Fig. 9 enhancement face (Fig. 10-A). Make sure the wires do not kink or have twists in them. 3: Mount the new power supply module to the enhancement module using t
ページ4に含まれる内容の要旨
6: Crimp the butt connector to the severed media cartridge enhancement grid wire (Fig. 13). Please note that the grid wires will typically be black. 7: Crimp the opposite side of the butt connector to the black replacement power supply wire (Fig. 14). CAUTION UNIT OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation. Make sure the high voltage wire is routed behind the horizontal fiberglass rod. Fig. 13 Fig. 14 CAUTION UNIT OPERATION HAZARD