ページ1に含まれる内容の要旨 
                    
                         
TM
Data Sheet: Supereta iQN Series –Single Output Quarter Brick 
 
 
      
Supereta™ iQN Series DC/DC Power Modules 
     48V Input, 35V / 6A Output  
Quarter Brick
 
 
The Supereta™ iQN series offers an industry 
standard quarter brick high current power 
module with true useable output power. The 
iQN series power modules with the voltage 
foldback constant current limit feature are 
ideally suited for fan motor control and 
wireless applications. Its 90% full load 
efficiency (91% at 70% o
                    
                    ページ2に含まれる内容の要旨 
                    
                          TM Data Sheet: Supereta iQN Series –Single Output Quarter Brick         Ordering information:    Product Package Platform Input Output Output Main # of  Safety Feature Set  Identifier Size Voltage Current/ Units Output Outputs Class  Power Voltage  i Q N 48 006 A 350 V - 0 00    Quarter- TDK Innoveta  Supereta  36-75V 006 – 6 A Amps 350 – 35V Single   00 – Standard  brick            Option Table:      Feature Set On/Off Logic OVP Pin Length Special Code    00 Positive Latch 0.145” No    01 Neg
                    
                    ページ3に含まれる内容の要旨 
                    
                           TM Data Sheet: Supereta iQN Series –Single Output Quarter Brick    Mechanical Specification:  Dimensions are in mm [in].  Unless otherwise specified tolerances are: x.x ± 0.5 [0.02], x.xx and x.xxx ± 0.25 [0.010].                           1.02 [.040] DIA 1.52 [.060] DIA 6 pins 2 pins M3 X .5 threaded   inserts, 2 places                                 8 1    7 2 6   5 3 3.40 [0.134] max Dia 4   2 places           Recommended hole pattern (top view)     Pin Assignment:      PIN FUNCTION PIN F
                    
                    ページ4に含まれる内容の要旨 
                    
                           TM Data Sheet: Supereta iQN Series –Single Output Quarter Brick      Absolute Maximum Ratings:    Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.    Characteristic Min Max Unit Notes & Conditions  Continuous Input Voltage -0.5 80 Vdc   Transient Input Voltage  --- 100 Vdc 100mS max.    Isolation Voltage            Input to Output --- 1500 Vdc Basic Insulation        Input to Base-plate --- 1500 Vdc Basic Insulation        Output to Base-plate --- 500 Vdc
                    
                    ページ5に含まれる内容の要旨 
                    
                           TM Data Sheet: Supereta iQN Series –Single Output Quarter Brick      Electrical Data:    iQN48006A350V-000 through -0A9: 35V, 6A Output    Characteristic Min Typ Max Unit Notes & Conditions  Output Open Circuit Voltage Set-point 34.65 35 35.35 Vdc Vin=Vin,min to Vin,max, Io=0A, Tc = 25˚C  Over all rated input voltage and temperature  Output Voltage Initial Set-point Tolerance 34.48 35 35.53 Vdc  conditions with Io=0A to end of life  Efficiency  --- 90 --- % Vin=Vin,nom; Io=Io,max; Tc = 25˚C  
                    
                    ページ6に含まれる内容の要旨 
                    
                            TM Data Sheet: Supereta iQN Series –Single Output Quarter Brick          Electrical Characteristics: iQN48006A350V-000 through -0A9: 35V, 6A Output       28 94 24 92 20 90 16 88 86 12 84 8 82 4 80 0 1 2 3 4 5 6 1 2 3 4 5 6 Output Current (A) Output Current (A) Vin = 36V Vin = 48V Vin = 75V Vin = 60V Vin = 36V Vin = 48V Vin = 75V Vin = 60V Efficiency vs. Input Voltage at Ta=25C, No Heat Sink Power Dissipation vs. Input Voltage at Ta=25C, No   Heat Sink     7 6 5 4 3 2 1 0 30 35 40 45 50 55 60
                    
                    ページ7に含まれる内容の要旨 
                    
                            TM Data Sheet: Supereta iQN Series –Single Output Quarter Brick      Electrical Characteristics (continued): iQN48006A350V-000 through -0A9: 35V, 6A Output      40 30 20 10 0 0 1 2 3 4 5 6 7 Output Current (A) Vin = 36V Vin = 48V Vin = 75V Vin = 60V   Output Current Limit Characteristics vs. Input Voltage at Typical Output Ripple at 48V Input and Full Load.  Ta=25C. Cext=68uF.   Ch. 1: Vo    36 36 35 35 34 34 33 33 32 32 31 31 30 30 29 29 36 41 46 51 56 61 66 71 76 0 1 2 3 4 5 6 Input Voltag
                    
                    ページ8に含まれる内容の要旨 
                    
                          TM   Data Sheet: Supereta iQN Series –Single Output Quarter Brick    Thermal Performance:  iQN48006A350V-000 through -0A9: 35V, 6A Output    7 7    6 6 5 5 4 4 3 3 2 2 60 70 80 90 100 110 120 80 90 100 110 120 130 Ambient Temperature (C) Ambient Temperature (C) 1.0 m/s (200 LFM) 1.25 m/s (250 LFM) 1.5 m/s (300 LFM) 1.0 m/s (200 LFM) 1.25 m/s (250 LFM) 1.5 m/s (300 LFM) 1.75 m/s (350 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 1.75 m/s (350 LFM) 2.0 m/s (400 LFM) 2.5 m/s (500 LFM) 3.0 m/s (600 LFM
                    
                    ページ9に含まれる内容の要旨 
                    
                          TM    Data Sheet: Supereta iQN Series –Single Output Quarter Brick        Thermal Management:  rectangular with the spacing between the    top of the module and a parallel facing PCB  An important part of the overall system  kept at a constant (0.5 in).  The power  design process is thermal management;  module’s orientation with respect to the  thermal design must be considered at all  airflow direction can have a significant  levels to ensure good reliability and lifetime  impact on the unit’
                    
                    ページ10に含まれる内容の要旨 
                    
                           TM  Data Sheet: Supereta iQN Series –Single Output Quarter Brick           performance page for the power module of (longitudinal – perpendicular to the direction  interest.  In all conditions, the power module of the pins and transverse – parallel to the  should be operated below the maximum direction of the pins).  The heatsink kit  operating temperature shown on  contains four M3 x 0.5 steel mounting  the derating curve.  For improved design  screws and a precut thermal interface pad  marg
                    
                    ページ11に含まれる内容の要旨 
                    
                          TM    Data Sheet: Supereta iQN Series –Single Output Quarter Brick            Operating Information:        Over-Current Protection: The power  safeguard the units against thermal damage.   modules have current limit protection to  The module will be latched off. To reset the  protect the module during output overload  module from the latched condition, either  and short circuit conditions.  During overload  cycle the input power or toggle the remote  conditions, the power modules may protect 
                    
                    ページ12に含まれる内容の要旨 
                    
                           TM   Data Sheet: Supereta iQN Series –Single Output Quarter Brick            Vout(+) Vin (+) Sense(+) On/ Off Trim Rdown Sense(-) Vin(-) Vout(-)         Circuit to decrease output voltage  On/Off Circuit for positive or negative logic           Output Voltage Adjustment: The output  10000 voltage of the module may be adjusted by  using an external resistor connected  between the trim pin 6 and either the Sense  1000 (+) or Sense (-) pin.  If the voltage trim  feature is not used, pin 6 should
                    
                    ページ13に含まれる内容の要旨 
                    
                           TM  Data Sheet: Supereta iQN Series –Single Output Quarter Brick           Vout(+) Remote Sense: The power modules feature  remote sense to compensate for the effect  Sense(+) of output distribution drops.  The output   Rup voltage sense range defines the maximum  voltage allowed between the output power   terminals and output sense terminals, and it  Trim is found on the electrical data page for the  power module of interest.  If the remote  Sense(-) sense feature is not being used, the  Sen
                    
                    ページ14に含まれる内容の要旨 
                    
                           TM  Data Sheet: Supereta iQN Series –Single Output Quarter Brick           nominal input, full load, and Ta = 40˚C using Quality:  the Telcordia TR-332 issue 6 calculation   method.  TDK Innoveta’s product development   process incorporates advanced quality  Improper handling or cleaning processes planning tools such as FMEA and Cpk  can adversely affect the appearance, analysis to ensure designs are robust and  testability, and reliability of the power reliable.  All products are assembled a
                    
                    ページ15に含まれる内容の要旨 
                    
                           TM Data Sheet: Supereta iQN Series –Single Output Quarter Brick        Safety Considerations:    1) The input source is isolated from the  For safety agency approval of the system in ac mains by reinforced insulation.  which the DC-DC power module is installed, 2) The input terminal pins are not  the power module must be installed in accessible.  compliance with the creepage and clearance 3) One pole of the input and one pole of  requirements of the safety agency.  The the output are grounded