ページ1に含まれる内容の要旨 
                    
                        WARNING
CONFORMS TO
ANSI/UL-325 53382
CERTIFIED TO
CAN/CSA C22.2 NO. 247
VEHICULAR GATE OPERATOR
CLASS HP
MOVING GATE CAN CAUSE
MODEL SERIOUS INJURY OR DEATH
SERIAL Operate gate only when gate area is in sight
and free of people and obstructions.
VOLTS PHASE
Do not allow children to play in gate area
AMPS 60 Hz or operate gate.
MAX GATE LOAD Do not stand in gate path or walk through
path while gate is moving.
DoorKing, Inc., Inglewood, CA Read owner’s manual and safety instructions.
Owner’s Manu
                    
                    ページ2に含まれる内容の要旨 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ3に含まれる内容の要旨 
                    
                        6050 / 6100 SPECIFICATIONS UL325 Class of Operation Model 6050 Class I Only ; Model 6100 Class I, II, III, IV  Type of Gate Vehicular Swing Gates Only  Horsepower 1/2 HP  Voltage / Phase 115 VAC Single-Phase  Current Model 6050 1/2 HP –  4.3 Amps @ 120V ; Model 6100 1/2 HP –  5.4 Amps @ 120V  Max Gate Weight Model 6050 - 400 Lbs. ;  Model 6100 - 500 Lbs.  Max Gate Length Model 6050 - 10 Ft. ; Model 6100 - 14 Ft.  Cycles Per Hour Model 6050 - 10 Per Hour ; Model 6100 - 60 Per Hour  Speed 90° in a
                    
                    ページ4に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS SPECIFICATIONS 1 Gate Construction 4 Important Safety Instructions 4 Instructions regarding intended installation: 4 Important Notices 5 UL325 Entrapment Protection 6 Glossary 7 Swing Gate Requirements 8 Swing Gate Protection 9 SECTION 1 - INSTALLATION 10 1.1 Operator Position 10 1.2 Post Mount or Pad Mount Base Assembly 10 1.3 Underground Conduit Requirements 11-12 1.4 Pad Mount 13 1.5 Post Mount 13 1.6 Arm and Gate Bracket Installation 14 1.7 Manually Adjust the Open and Clos
                    
                    ページ5に含まれる内容の要旨 
                    
                        2.6 Control Wiring 19 2.7 Loop Detector Wiring 20 2.8 Primary / Secondary (Dual) Gate Connection 21 SECTION 3 - ADJUSTMENTS 22 3.1 4502 Circuit Board Adjustments 22 3.2 DIP-Switch Settings 23-24 3.3 Automatic Limit Adjustment 25 3.4 Entrapment Sensing Adjustment (Adjustable Clutch) 25 3.5 Secondary Entrapment Protection System 25 SECTION 4 - OPERATING INSTRUCTIONS 26 4.1 Power and Reset Switches 26 4.2 Shutdown Conditions 27-28 Soft Shutdown Hard Shutdown 4.3 Manual Gate Operation 28-29 Emergenc
                    
                    ページ6に含まれる内容の要旨 
                    
                        Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated  Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or  www.astm.org. Important Safety Instructions WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always 
                    
                    ページ7に含まれる内容の要旨 
                    
                         For gate operators utilizing contact sensors:   1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such as at the       leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate.   2. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate.   3. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate.   4. A hardwi
                    
                    ページ8に含まれる内容の要旨 
                    
                        STATE PRISON UL325 Entrapment Protection Class I Class II A vehicular gate operator (or system) intended for use in a A vehicular gate operator (or system) intended for use in a  home of one-to four single family dwelling, or a garage or commercial location or building such as a multi-family  parking area associated therewith. housing unit (five or more single family units) hotel,  garages, retail store or other building servicing the general  public. Class III Class IV A vehicular gate operator
                    
                    ページ9に含まれる内容の要旨 
                    
                        Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage  barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and  completes the perimeter of a defined area. RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS I - A vehicular gate operator (or system) intended for use in a home  of one-to four single family dwelling, or garage or parking area associated therewith. COMM
                    
                    ページ10に含まれる内容の要旨 
                    
                        Swing Gate Requirements The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate  access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that  persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. (ref. UL325 56.8.4.b) Closed Gates Closed Gate Closed Gate A If space is greater than 4 inches,  A With the hinge mounted 
                    
                    ページ11に含まれる内容の要旨 
                    
                        Swing Gate Protection C Non-contact Sensor Minimizes the potential  Reverse Loop of the gate closing on  Minimizes the potential of the gate  vehicular or other traffic  closing when a vehicle is present.  that loops cannot sense. Number and placement of loops is  dependent on the application. D C D D Warning Signs Shadow Loop Permanently mounted  and easily visible from  Provides a hold open command to  either side of the gate. the operator(s) only if the gate(s)  are at the full open position.
                    
                    ページ12に含まれる内容の要旨 
                    
                        Closed Gate SECTION 1 - INSTALLATION Prior to beginning the installation of the swing gate operator, we suggest that you become familiar with the  instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is  performed in an efficient and professional manner.  The proper installation of the vehicular swing gate operator is an extremely important and integral part of the  overall access control system. Check all local building ordinances and 
                    
                    ページ13に含まれる内容の要旨 
                    
                        1.2 Post Mount or Pad Mount Base Assembly  (2) 1” bolts through the main gear bracket mounting holes. (2) 1 1/2” bolts through the main gear bracket mounting holes. Post Support Base Screw the posts to the support  plate and mount into concrete  BEFORE attaching the operator. Hardware for Post Mount: (2) 1 1/2 inch bolts. For support plate. (2) 1 inch bolts. For support plate. (3) Non-slip nuts. For existing threaded   studs on bottom of operator. (2) 1” bolts through the main gear bracket mount
                    
                    ページ14に含まれる内容の要旨 
                    
                        1.3 Underground Conduit Requirements Primary Secondary Operator Operator Position Position Primary/Secondary Interconnection Cable (Dual Operator Application Only) Low Voltage Control and/or P.A.M.S. Wires Low Voltage Loop Lead-In Wires High Voltage Power Concrete Pad Sweeps 3/4 Inch Minimum Never run high voltage and low voltage wires in the same conduit.  The conduit requirements are for a typical swing gate operator installation (the secondary operator is shown for    those applications wher
                    
                    ページ15に含まれる内容の要旨 
                    
                        Gate Bracket Note: 2” thick gate Illustrated. 1.5 Post Mount These measurements will work for standard or  convenience open models from 1.1 layout on page 10 ONLY. Mount the post base into the concrete  90° before installing the operator. Open Gate The post mount installation will allow  the operator to be mounted low enough  Concrete 6” to attach the gate bracket to the lower  Position gate rail if desired. 25.25” Post Base 29” 10” Conduit Operator MUST  18.5” be level. Run all conduit on the o
                    
                    ページ16に含まれる内容の要旨 
                    
                        Open Gate Open Gate Crank Power Arm Crank Arm 1.7 Manually Adjust the Open and Closed Gate Positions DO NOT power up the operator to set the open and closed gate positions. The first time the operator is powered up and  cycled, it will automatically set the open and close limits. To do this, the arms MUST already be in the correct configuration. Closed Arms Position Open Arms Position Closed Gate 90° 90° Arms must be on the  imaginary straight line. Approximate pivot  point distances. Elbow flan
                    
                    ページ17に含まれる内容の要旨 
                    
                        Imaginary Line Elbow Assembly Connecting Arm Crank Arm 62.25” 40” 22.25” 44.5” 22.25” 8.5” Open Gate 1.9 Gates Opening Wider Than 90° The installation of an operator opening gates wider that 90° is the same for 1.3 through 1.8 except the operator and concrete  pad will be in a different position. Individual requirements can be calculated following this 105° demonstrated sample. Arm Assembly Connecting arm’s pivot point measurement 3 62.25” minus (crank arm) 22.25” =  40” An imaginary line drawn 
                    
                    ページ18に含まれる内容の要旨 
                    
                        SECTION 2 - WIRING Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF  position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a  licensed electrical contractor perform this work.  Since building codes vary from city to city, we highly recommend that you check with your local building department prior  to installing any permanent wiring to be sure that a
                    
                    ページ19に含まれる内容の要旨 
                    
                        12345678 12345678 ON 1 2 3 4 5 6 7 8 ON ON ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 2.3 Main Terminal Description  When gate is closed, input will open gate. DANGER  When gate is open and auto close HIGH VOLTAGE! timer SW 1, switch 4 is turned on,  input will re-set and hold timer. 11 115 VAC POWER NEUTRAL 1  When gate is open and auto close  timer SW 1, switch 4 is turned off,  115 VAC POWER NEUTRAL input will close gate. 2 Output to Secondary Operator  When gat
                    
                    ページ20に含まれる内容の要旨 
                    
                        ON ON 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 N 2 3 4 5 6 7 8 NC 17 2.4 Auxiliary Terminal Description NO 18 Tracker LEDs 19 20 4502 18 2 3 4 5 6 7 1. ALARM OUTPUT Provides power to activate the entrapment alarm. 2. ALARM RESET INPUT Input to reset the operator after an entrapment alarm. 3. COMMON Common for alarm output and alarm reset input. 4. TRACKER DATA Supplies gate operator data to Tracker expansion board (P/N 2351-010). Refer to the Tracker Installation   and Wiring Manual for detailed informat