ページ1に含まれる内容の要旨 
                    
                        5401 Airborne Disciplined Rubidium Oscillator
5402 Disciplined Rubidium Oscillator
Operating Manual
Preliminary Rev. A, May 2005
PN 8500-0150                                                                                                                                                                                                                                                                                                                                                                       
                    
                    ページ2に含まれる内容の要旨 
                    
                        Symmetricom, Inc. 2300 Orchard Parkway San Jose, CA 95131-1017 U.S.A. http://www.symmetricom.com Copyright © 1999–2005 Symmetricom, Inc. All rights reserved. Printed in U.S.A. This manual is provided to assist the user in the operation and maintenance of the supplied equipment  or software. It is recognized that multiple copies may be required to support even a single unit, and for  this reason, permission is hereby granted to reproduce the supplied manual for the purpose stated  above, provided
                    
                    ページ3に含まれる内容の要旨 
                    
                        Operating Manual Preface  Preface Limited Warranty  Each new product manufactured by Symmetricom is warranted for defects in material or  workmanship for a period of one year from date of shipment (“Limited Warranty”). Defects in  material or workmanship found within that period will be replaced or repaired, at  Symmetricom’s option, without charge for material or labor, provided the customer returns the  equipment, freight prepaid, to the Symmetricom factory under this limited warranty.  Symmet
                    
                    ページ4に含まれる内容の要旨 
                    
                        Operating Manual Preface Limitation of Liability  By purchasing any product from Symmetricom, the Buyer consents to and agrees that the  Buyer’s sole and exclusive remedy for any damages or losses incurred by the Buyer as a  result of Symmetricom’s breach of its one-year Limited Warranty for defects in materials and  workmanship or otherwise in connection with any claim respecting the product shall be  limited to the repair or replacement of the product or a refund of the sales price of the prod
                    
                    ページ5に含まれる内容の要旨 
                    
                        Operating Manual Preface ESD Caution: To avoid personal injury and electrostatic discharge (ESD) damage to  equipment, do not disregard ESD cautions. All ESD cautions use this symbol. ESD cau- tions are installation, operation, or maintenance procedures, practices, conditions, or  statements that if not strictly observed, may result in possible personal injury, electro- static discharge damage to, or destruction of, static-sensitive components of the equip- ment. Electrical Shock Caution: To avo
                    
                    ページ6に含まれる内容の要旨 
                    
                        Operating Manual Preface Table 2  Typographical Conventions  When text appears  ... it means: this way... SSU-2000 User’s Guide The title of a document. SSU An operating mode, alarm state, status, or chassis label. CRITICAL IOC1 Select File, Open... Click the Open option on the File menu. A named keyboard key. Press Enter The key name is shown as it appears on the keyboard. An  Press ; explanation of the key’s acronym or function immediately fol- lows the first reference to the key, if required.
                    
                    ページ7に含まれる内容の要旨 
                    
                        Operating Manual Contents Preface Limited Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii Limitation of Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Proprietary Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv Where to Find Answers to Product and Document Questions . . . . . . . . . . . . . iv Warnings, Cautions, Recommendati
                    
                    ページ8に含まれる内容の要旨 
                    
                        Operating Manual Burst Status On. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Burst Status Off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14 Request TI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Enter DAC Value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Request Firmware Version . . . . . . . . . . . . . . .
                    
                    ページ9に含まれる内容の要旨 
                    
                        Operating Manual Introduction 1 —  Introduction Product Overview The purpose of the Symmetricom 5401 Airborne Disciplined Rubidium and 5402 Disciplined  Rubidium Oscillator (DRO) is to provide a precise time and frequency reference for other  equipment. The DRO will base this reference on a precise 1 PPS input, typically from a GPS  Receiver. At the 1 PPS time signal input rollover, the DRO will measure the time difference  between it and the internal Rubidium oscillator. It will continuously co
                    
                    ページ10に含まれる内容の要旨 
                    
                        Operating Manual Introduction Symmetricom 5401 Airborne Disciplined Rubidium Oscillator  The Symmetricom 5401 is built in an airborne package that is powered by standard aircraft  power (+28 VDC) and is installed by mounting the chassis on a flat base plate. Refer to  Chapter 4 for complete specifications. Figure 1 Symmetricom 5401 3-View Symmetricom 5402 Disciplined Rubidium Oscillator  The Symmetricom 5402 is built in a standard rack mount configuration that is powered by  commercial power any
                    
                    ページ11に含まれる内容の要旨 
                    
                        Operating Manual Installation 2 — Installation Installation This section describes the unpacking, inspection, installation, and operation of the  Symmetricom 5401 and 5402 Disciplined Rubidium Oscillators.   Unpacking and Inspection  The DRO is packaged in one shipping container. Inspect the unit for visible damage  (scratches, dents, etc.). If the instrument is damaged, immediately notify both Symmetricom  and the responsible carrier. Keep the shipping container and packing material for the car
                    
                    ページ12に含まれる内容の要旨 
                    
                        Operating Manual Installation The 5401 is now operational and will begin to discipline the Rubidium using the control  parameters that were previously stored in battery-backed RAM when the unit was last  powered-down.  Symmetricom 5401 Adjustments  The amplitude of each of the 10 MHz outputs can be individually adjusted with  potentiometers located on the 3-Channel Distribution Amplifier (Assembly 35039).  In order to gain access to these adjustments, do the following: (The 5401 is viewed from t
                    
                    ページ13に含まれる内容の要旨 
                    
                        Operating Manual Installation Symmetricom 5402 Rack Mounting Procedure  The 5402 is designed for standard nineteen-inch rack mounting.  Optional chassis slides are recommended if the unit is to be installed in an equipment rack. If  slides are not used, a supporting bar or tray should be provided for the rear of the instrument.  The chassis slides attach to the sides of the 5402. To mount the slides, use six # 8/32 screws,  1/2 inch long (three on each side).  Caution: If the 5402 is mounted in 
                    
                    ページ14に含まれる内容の要旨 
                    
                        Operating Manual Installation Symmetricom 5402 Installation Procedure  1. Install the unit in the desired location and connect the unit to an AC power source. Refer  to Chapter 4 for specifications and connector designations and locations.  2. Connect the 1 PPS input to its 1 PPS source and connect the 1 PPS and 10 MHz outputs  to their desired destinations.  Connection to the RS232 I/O is not necessary for operation, but it is desirable in order to  monitor status or enter new control parameter
                    
                    ページ15に含まれる内容の要旨 
                    
                        Operating Manual Operation 3 — Operation Neither the 5401 nor the 5402 have any external manual controls. Signal output amplitude is  controlled by internal potentiometers, which are located as described in Chapter 2. All  operational control of the DRO is accomplished by means of an RS-232 input/output port.   RS-232 Input/Output  The DRO has been equipped with an RS-232 interface using a 13-pin MS type connector  designated as J14 RS232 on the 5401, and using a DB15 connector designated as J3 
                    
                    ページ16に含まれる内容の要旨 
                    
                        Operating Manual Operation Table 1  DRO Commands Via RS-232 Status Request Command Format: PN 8500-0150, Rev. A, May 2005 8                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    ページ17に含まれる内容の要旨 
                    
                        Operating Manual Operation Description:  Rx - Rubidium lock; x=0 not Locked, x=1 Locked  Dx - Discipline On/Off; x=0 discipline off, x=1 discipline on  Px - 1 PPS input present; x=0 not present, x=1 present  Vx - Valid 1 PPs; x=0 unstable, x=1 stable. Time change in the 1 PPS is less than the rate  threshold.  Ttttttt.ttt - Time Interval; tttttt.ttt is the time interval (0 to 999999.999 microseconds) of the last  1 PPS event.  Sssssss.s - Seconds Counter; ssssss.s is the second count (0 to 99999
                    
                    ページ18に含まれる内容の要旨 
                    
                        Operating Manual Operation Response Format: Discipline On Command Format: Description: The oscillator discipline is turned on. When the conditions are favorable, the discipline  algorithm will control the oscillator. Response Format: Dynamic Gain Control  Command Format: Description:  The dynamic gain value determines the response time of the control loop. This command  sets the upper and lower limit.  Fgg.g - Dynamic Gain Floor; the lowest value allowed for dynamic gain.  Cgg.g - Dynamic Gain C
                    
                    ページ19に含まれる内容の要旨 
                    
                        Operating Manual Operation Dynamic Gain Time Constant 4 90 minutes 5 70 minutes 8 45 minutes 10 35 minutes 20 17 minutes 30 11 minutes Response Format: Enter KM  Command Format: Description:  kkkkkk - Base number for Km; kkkkkk (000000 to 999999) represents a number from 0 to  0.999999. Km controls the mix ratio of offset error and frequency error compensation in the  discipline algorithm.  Response Format:  Enter KO1, KO2  Command Format:  PN 8500-0150, Rev. A, May 2005 11                      
                    
                    ページ20に含まれる内容の要旨 
                    
                        Operating Manual Operation Description: nnnnnn - Base number for Ko1; nnnnnn (000000 to 999999) represents a number from 0 to  0.999999. Ko1 controls the cut off frequency of the offset error noise filter. oooooo - Base number for Ko2; oooooo (000000 to 999999) represents a number from 0 to  0.999999. Ko2 controls the cut off frequency of the frequency error noise filter. Response Format:  Enter Disgain  Command Format:  Description: ddddd - Base number for Disgain; ddddd (00000 to 99999) contro