ページ1に含まれる内容の要旨 
                    
                        DS Series Manual 
 
 
DATA SWITCH  
DS62 Host Ethernet Module 
& 
DS62-MD4 Host Ethernet-Modem Module 
 
 
 
 
 
 
 
 
BayTech Manual Publication 
Revision: May 2008 
                                                                                                                                                                                                                                                                                                                                             
                    
                    ページ2に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module      Copyright 2007 by Bay Technical Associates, Inc.    BayTech, is a registered trademarks of Bay Technical Associates, Inc.    Windows 2000®, Windows XP® are products and registered trademark of Microsoft  Corporation.    Tera Term is a product and registered trademark of Vector, Inc.                      2                                                                                                                                            
                    
                    ページ3に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module    ABOUT THIS OWNER’S MANUAL ........................................................................................................5  Connection Description.......................................................................................................................6  EIA-232 SERIAL CONNECTION.....................................................................................................6  Internal MODEM CONNECTION.................
                    
                    ページ4に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  DS Management ...............................................................................................................................35  Internal Alarm Threshold ...............................................................................................................35  External Alarm Threshold..............................................................................................................36  Outlet Groups .............
                    
                    ページ5に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  ABOUT THIS OWNER’S MANUAL    This document is applicable to the DS62 Network Module and the DS62-MD4 Network/Modem  Module EXCEPT those paragraphs specifically mentioning the DS62-MD4 do not apply to the  DS62. This document provides information required for installing and operating your Bay Tech  equipment. It should allow the user to connect to, power up, and access an applications menu where  peripheral equipment can be controlled. We recommen
                    
                    ページ6に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Connection Description  BayTech's host communication module provides an interface that controls user access to the DS Series  data switch and other DS Series connected modules.   EIA-232 SERIAL CONNECTION   The DS-Series host communications modules have an RJ-45 port which uses an 8-pin crossed modular  cable to connect to a local EIA-232 device such as a computer terminal or external modem. Most serial  computers do not have RJ-45 connections; t
                    
                    ページ7に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module    PREPARING THE INSTALLATION SITE    The installation area should be clean and free of extreme temperatures and humidity.  Allow sufficient  space behind the DS unit for cabling and receptacle connections. Access to installation site should be  restricted to authorized personnel. Installation of these units should be limited to ITE and Telco server  environments.    Power  CAUTION: This unit is intended for indoor use only. Do not install near wa
                    
                    ページ8に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  5. Select ‘C’ for the configuration menu.   6. Select the HOST module. You should see a menu similar to (Figure 2).  7. Select the number for ‘Login Setup’ option. You should see a menu similar to (Figure 3).  8. Select the number for ‘Manage Users’ option. You should see a menu similar to (Figure 4).  9. NOTE: The ‘root’ user can not be deleted.  10. Select ‘A’ to add user. Type the name and password at the prompts.  11. Press ‘Enter’ until get 
                    
                    ページ9に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Figure 1  DS-Series - F 2.10.05     (C) 2005 Bay Technical Associates      Module Name: DS62        Module: 1      Attention Character:  ;      Device A         (2, 1).........1      Device B         (2, 2).........2      Device C         (2, 3).........3      Device D         (2, 4).........4      DS-DS            (5, 1).........5      Status..........................S  Current configuration      Configure.......................C  Make Changes  
                    
                    ページ10に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Attention Character  If no Baytech power strips are to be controlled through this Data Server, skip this step. Pressing the  Attention Character 5 consecutive times will access the network main menu. The Default is a semi- colon (;). Select this option to change the attention character. The DS displays the following:      Attention Character is...........  ;      Enter Attention Character :  Login Setup Menu  Figure 3      Access Control.........
                    
                    ページ11に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Radius Configuration  Radius is used to authenticate logins for the serial and the network ports if passwords and user names  are enabled on the DS. If the Radius server rejects either the username or password or does not  respond, the DS will display “Invalid Password”.      TACACS Configuration  TACACS can be used to authenticate logins for the serial port, the network port, and modem. When a  telnet / SSH session (or rs232 session) is started 
                    
                    ページ12に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module    Cabling  RJ-45 Cables and Adapters    DS62 EIA-232 RJ-45 Signal  Pin EIA 232 Signal Description  Signal Direction  1 DTR Out Handshake, Line Driver Inactive State = High: +12V when power is  applied. Used as a handshake line to enable/disable the receiving of  characters.  2 GND  Signal Ground  3 RTS Out Handshake, Line Driver Inactive State = High: +12 V when power is  applied. Not used to enable/disable.  4 TX Out Transmit Data Out  5 RX In R
                    
                    ページ13に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Adapters  9FRJ45PC (With Cisco Interface)             9FRJ45PC-1 (Without Cisco Interface)     RJ08X007        Figures 1 and 2 provide visual representation of an RJ-45 receptacle and plug.            13                                                                                                                                                                                                                                                       
                    
                    ページ14に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Detail Operations and Configurations  NOTE: Depending on the DS-Series model, the menus may vary according to the number of DS74  modules installed in the unit. If this is not an initial set-up and Password has already been enabled, you  are prompted to login. After logging in successfully, invoke the main menu by sending the attention  character five times (;;;;;).    NOTE: Password feature is case sensitive. Default is ‘root/baytech’.  Main Scr
                    
                    ページ15に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Accept changes ? (Y/N) :y Changes accepted.      Unit Configuration Menu   The configuration menu allows the admin user to establish the parameters the DS-Series will operate.    Configuration    DS62             module #1..........1    DS74             module #2..........2    DS-RPC           module #5..........3    Enter Request :      Select the number of the host module and the following menu is displayed:  Copyright(C) Bay Technical Associat
                    
                    ページ16に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Installed Modules :01,02,05    Attention Character is ......... ;    Disconnect Time Guard is........ Disabled    Port ID Echo is................. Disabled    Module Name is.................. DS62      Network Connectivity & Login Configuration:    Ethernet Address................  00:C0:48:00:01:FD    IP Address...................... 0.0.0.0    Subnet Mask..................... 0.0.0.0    Default Gateway................. 0.0.0.0    Inactivity Tim
                    
                    ページ17に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Serial Port Configuration  Handshaking, Baud Rate, Word Size, Stop Bits, and Parity are configured through either the serial or  Ethernet ports using the menus.  RTS and DTR Line Drivers can only be configured through the phone  line via a modem.  The default settings are 9600bps, 8 data bits, no parity, one stop bit, RTS and  DTR High.    IMPORTANT: Changing the Host module serial port configuration could create a  communications lock-out if the
                    
                    ページ18に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  via binary, it is very likely that these values could be transmitted as data and the transmission  would fail.     2. Hardware Handshaking: This style uses actual hardware lines. Like the TX and Rx lines, the  RTS/CTS and DTR/DSR lines work together. When a receiver is ready for data, it will assert  the RTS (Request to Send) line. This is then read by the sender at the CTS (Clear to Send)  input, indicating it is clear to send the data. DTR (Dat
                    
                    ページ19に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  Stop Bits  The Stop Bits are used to signal the end of communication for a single packet. Since the data is  clocked across the lines and each device has its own clock, it is possible for the two devices to become  slightly out of sync. Therefore, the stop bits not only indicate the end of transmission but also give the  computers some room for error in the clock speeds. The more bits that are used for stop bits, the  greater the lenience in sync
                    
                    ページ20に含まれる内容の要旨 
                    
                        DS62-Network, DS62-MD4 Network/Modem Host Module  DTR Line Driver Inactive State is: High High ? (Y/N, CR for no change):      Serial Port Device Name  Select a port and type the new name.    Current device name: EIA-RS232 Enter device name for serial port ((1 - 16 char., CR to end) :    Attention Character  Pressing the Attention Character 5 consecutive times will access the network main menu. The Default  is a semi-colon (;). Select this option to change the attention character. The DS display