ページ1に含まれる内容の要旨
MS-08 MAGIC SWITCH
USER’S GUIDE
MICROWAVE CONTACTLESS SWITCH FOR AUTOMATIC DOORS
1 Description
Screw
Screws
Microwave
Microwave
Motion
Motion
Sensor
Sensor
Screw
Screws
Adapter Ring
Faceplate
Faceplate
SINGLE GANG DOUBLE GANG
MS-08 MAGIC SWITCH
(10MS08U)
2 Specifi cations
DESCRIPTION SPECIFICATION
Technology Microwave motion sensor
Radiated Frequency 24.125 GHz
Radiated Power Density 5 mW/cm²
Supply voltage 12 to 24VAC ± 10%
12 to 24VDC +30% / -10%
Supply Frequency 50 to 60Hz
Power Consumpti
ページ2に含まれる内容の要旨
3 Precautions Shut off all power going to wall outlet before attempting any wiring procedures. Maintain a clean & safe environment when working in public areas. Constantly be aware of pedestrian traffi c around the door area. Always stop pedestrian traffi c through the doorway when performing tests that may result in unexpected reactions by the door. ESD electrostatic discharge: Circuit boards are vulnerable to damage by electrostatic discharge. Before handling any board ensure you dissipa
ページ3に含まれる内容の要旨
5 Installation and Wiring (Continued) Setup 3 Toggle Mode Pot Output Mode Switch 4” 24” 4” Pulse Mode 24” MS-08 Sensing Filed 1. Adjust unit to desired setup. Two adjustments can be made to the 2. Adjust Output Mode by moving switch in the up position (Toggle sensor. The Potentiometer is used to adjust the size of the units’ Mode) or in the down positon (Pulse Mode). sensing fi eld and the Output Mode switch is used to select Toggle or Pulse mode. Toggle Mode: Recommended for switch appli