Model 1510 Media Air Cleaner
Installation Instructions
WARNING CAUTION
1. High voltage may cause serious 1. T o prevent component failure, do not install the air cleaner on the warm
injury from electrical shock. air supply or in an area where the temperature may exceed 140°F. This
Disconnect power to the may include areas above heat exchangers in downflow furnaces or above
furnace/air handler before exhaust flues in lowboy furnace cold air returns.
starting installation. 2. Installation
ページ2に含まれる内容の要旨
AIR FLOW INSTALL THE AIR CLEANER CABINET LOCATING THE AIR CLEANER 1. Leave sufficient space in front of the air cleaner for the removal of the filtering media (see Figure 1). 2. DO NOT INSTALL DOWNSTREAM OF A UV LIGHT. UV lamps will cause degradation of the filtering media. 3. Figure 1 shows typical application of the air cleaner mounted to a horizontal system. 4. Figure 2 shows the air cleaner mounted to the side of a geothermal heat pump. FIGURE 1 FIGURE 2 45° MAX 29" 10-10998 90-1769 2
ページ3に含まれる内容の要旨
INSTALLATION 1. Disconnect power to the furnace or air handler at the electrical FIGURE 3 service panel. WARNING 120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed. Expand clean filter. 2. Remove the air cleaner door from the outer housing and pull out the filtering media. Install filter with Air Flow pointing toward Furnace or Air Handler. 3. If re
ページ4に含まれる内容の要旨