Industrial 3-Port Fast Ethernet POF 
Media Converter Switches 
 
KCD-303P-A series 
KCD-303P-B series 
 
 
Installation Guide 
 
 
 
 
 
 
 
 
 
 
 
 
DOC.081022 
1/18                                                                                                                                                                                                                                                                                                                                       
                    
                    ページ2に含まれる内容の要旨 
                    
                        (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in  any form or by any means or used to make any directive work (such as translation or transformation)  without permission from KTI Networks Inc.    KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from  time to time without obligation on the part of KTI Networks Inc. to provide notification of such  revision or change.    For more information, contact:
                    
                    ページ3に含まれる内容の要旨 
                    
                        The information contained in this document is subject to change without prior notice. Copyright (C)  All Rights Reserved.    TRADEMARKS  Ethernet is a registered trademark of Xerox Corp.   OptoLockTM is a registered trademark of Firecomms Ltd.    FCC NOTICE  This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two  conditions: (1) This device may not cause harmful interference, and (2) this device must accept any  interference received including the inte
                    
                    ページ4に含まれる内容の要旨 
                    
                        Table of Contents  1.  Introduction ................................................................................................................................5  1.1  Features..............................................................................................................6  1.2  Product Panels....................................................................................................6  1.3  Specifications .................................................................
                    
                    ページ5に含まれる内容の要旨 
                    
                        1.  Introduction  The industrial rated KCD-303P series supports three switched connections including copper and fiber  for networks over POF (Plastic Optical Fiber). The copper ports support 10/100Mbps auto-negotiation  and auto-MDI/MDIX for Cat.5 plug-and-play. The fiber ports support plug-less connections of high  bandwidth 100Mbps data rate over POF cables. POF technology offers a complementary solution to  UTP copper wire for industrial, office and home networks because it is low cost, weigh
                    
                    ページ6に含まれる内容の要旨 
                    
                         Screw panel-mounting support for industrial enclosure   Optional AC-DC power adapters with extended operating temperature range   Industrial-rated Emission and Immunity performance    1.1  Features   Supports 3 switching-base network segments – [2 x Copper, 1 x POF] and [1 x Copper, 2 x POF]   Auto MDI/MDI-X crossover function on the UTP copper port   Supports IEEE 802.3x flow control for full-duplex operation   Supports Back-pressure flow control for half-duplex operation   Wide operating temp
                    
                    ページ7に含まれる内容の要旨 
                    
                        KCD-303P-B      1.3  Specifications  Copper Ports  Compliance IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX  Connectors Shielded RJ-45 jacks  Pin assignments Auto MDI/MDI-X detection  Configuration Auto-negotiation  Transmission rate 10Mbps, 100Mbps  Duplex support Full/Half duplex  Network cable Cat.5 UTP up to 100 meters    POF Ports  TM Connectors OptoLock connector  Optical RCLED 650nm  Configuration 100Mbps, Full duplex  Network cables 1.5mm or 2.2mm POF (model dependent)  Distance 50 meters 
                    
                    ページ8に含まれる内容の要旨 
                    
                        Far End Fault Support Enabled    Switch Functions  MAC Addresses Table 1K entries  Forwarding & filtering Non-blocking, full wire speed  Switching technology Store and forward  Maximum packet length 1552 bytes max.  Flow control IEEE 802.3x pause frame base for full duplex operation  Back pressure for half duplex operation  Broadcast Storm Protection design    DC IN Power Input  Interfaces DC IN Jack ( -D 6.3mm / + D 2.0mm)  Operating Voltages +4.75 ~ 12.6VDC  Power Consumption 2W max.    Mechan
                    
                    ページ9に含まれる内容の要旨 
                    
                        2.  Installation  2.1  Unpacking  The product package contains:   The switch unit   One AC-DC power adapter   One product CD-ROM    2.2  Safety Cautions  To reduce the risk of bodily injury, electrical shock, fire, and damage to the product, observe the  following precautions.     Do not service any product except as explained in your system documentation.   Opening or removing covers may expose you to electrical shock.   Only a trained service technician should service components inside these c
                    
                    ページ10に含まれる内容の要旨 
                    
                        2.3  Mounting on a Wall  The device can be mounted on a desktop or shelf. Make sure that there is proper heat dissipation from  and adequate ventilation around the device. Do not place heavy objects on the device.    To mount the device on a wall, one wall mounting hole is provided on the bottom of the device. Hang  the device on the wall reliably. The following figure illustrates example of a device bottom face:      10/18                                                                         
                    
                    ページ11に含まれる内容の要旨 
                    
                        2.4  Panel Mounting  The switches support panel mounting in industrial enclosure. A panel mounting bracket is required for  the mounting. Install the bracket onto the device as shown in the figure below:        After bracket installation, the final dimension is shown below:  KCD-303P-A    KCD-303P-B    11/18                                                                                                                                                                                               
                    
                    ページ12に含まれる内容の要旨 
                    
                        2.5  Din-Rail Mounting  To mount the device on a Din-rail, the optional Din-rail mounting bracket is required. Install the  bracket onto the device.    After bracket installation, the device is ready to be mounted on a din-rail as shown below:      12/18                                                                                                                                                                                                                                                      
                    
                    ページ13に含まれる内容の要旨 
                    
                        2.6  Applying Power with Power Adapter  The device provides a DC power jack for receiving DC power input from an external AC-DC power  adapter.        Two types of AC-DC power adapters are available for choice. One is with typical operating  temperature rating and the other is with extended operating temperature rating for critical applications  as follows:    o o Typical Rating:   0 ~ 40 C operating temperature  o o Extended Rating:   -10 ~ 60 C operating temperature    One power adapter is pac
                    
                    ページ14に含まれる内容の要旨 
                    
                        2.7  Applying Power via USB  The USB port on the common computers provides an output of 5V/500mA, equally 5V/2.5Watt, for  the connected USB devices. With an USB DC power cable, the USB power is applicable to the devices  and serves as a handy power, and eliminates the need for extra power adapters and occupation of  limited AC power sockets.    One optional “USB DC power cable” is available for purchasing to supply power for the switch via  USB connection.    To make the connection, the steps a
                    
                    ページ15に含まれる内容の要旨 
                    
                        3.  Making LAN Connections  3.1  Making Copper Port (RJ-45) Connections  The copper ports support the following connection types and distances:  Network Cables  10BASE-T:  2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm  100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm  Link distance: Up to 100 meters    Auto MDI/MDI-X Function  This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid  MDI to MDI-X connection with the remote connected devic
                    
                    ページ16に含まれる内容の要旨 
                    
                        3.2  Making POF Connections  POF Cable  Depending on the model specified, two different sizes of POF cables are supported. One is 1.5mm and  the other is 2.2mm in diameter. The following figure illustrates 2.2mm POF and Cat.5 as comparison.    Easy POF Installation  The design of the device enables the POF to be cut and terminated to the exact required length on site,  allowing even the most novice user to quickly and easily terminate the bare POF fiber. To terminate  TM the POF cable into OptoL
                    
                    ページ17に含まれる内容の要旨 
                    
                        The following figure illustrates a connection example between two POF ports located on two devices:    Make sure the Rx-to-Tx connection rule is followed on the both ends of the cable.    3.3  LED Indication    LED     Function     State   Interpretation        POWER    Power status    ON   The power is supplied to the device.               OFF   The power is not supplied to the device.  Px Link/Act.  Port Px link status  ON   Port link is established. (No traffic)               BLINK  Port link
                    
                    ページ18に含まれる内容の要旨 
                    
                        4.  Applications  4.1  Application in Industrial Networks  The following figure illustrates an application example in an industrial network. Four devices are  cascaded by POF cables.      4.2  Application For Home Network  The following figure illustrates an application example in home network.      4.3  Copper to POF Media Converter Application  The following figure illustrates an application of copper Cat.5 to POF media conversion.      18/18