ページ1に含まれる内容の要旨 
                    
                           
    
    
R R R Ru u u ug g g gg g g ge e e ed d d dS S S Se e e er r r rv v v ve e e er r r r    R R R RS S S S4 4 4 41 1 1 16 6 6 6    
Modular Serial Device Server with Integrated Managed  
Ethernet Switch 
 
 
 
Installation Guide 
www.ruggedcom.com 
 
RuggedCom Inc. I 30 Whitmore Road, Woodbridge, Ontario, Canada L4L 7Z4  
Tel: (905) 856-5288 I Fax: (905) 856-1995 I Toll Free: (888) 264-0006 
                                                                                           
                    
                    ページ2に含まれる内容の要旨 
                    
                        Federal Communications Commission   Radio Frequency Interference Statement    This equipment has been tested and found to comply with the limits for a Class A digital device  pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection  against harmful interference when the equipment is operated in a commercial environment. This  equipment generates, uses and can radiate radio frequency energy and, if not installed and used in  accordance with the instruction 
                    
                    ページ3に含まれる内容の要旨 
                    
                        Table of Contents    1 Table of Figures ...................................................................................................................... 4  2 Table of Tables........................................................................................................................ 4  3 Product Overview .................................................................................................................... 6  3.1 Functional Overview...................................
                    
                    ページ4に含まれる内容の要旨 
                    
                        1 Table of Figures    Figure 1:  RS416 LED Display Panel ............................................................................................... 8  Figure 2: RS416 Series Rack mount chassis orientation options – Front and rear mount. ............ 10  Figure 3:  19” Rack Mount Adapters .............................................................................................. 11  Figure 4:  Rack mount adapter mounting location............................................................
                    
                    ページ5に含まれる内容の要旨 
                    
                        Table 13: Type Test Specification - Electrical Safety ..................................................................... 33  Table 14: Type Test Specification - Electrical Environment ........................................................... 33  Table 15: Type Test Specification - Atmospheric Environment...................................................... 33  Table 16: Operating Environment .................................................................................................. 
                    
                    ページ6に含まれる内容の要旨 
                    
                          3 Product Overview  3.1 Functional Overview    The RuggedServer™ RS416 is an industrially hardened serial device server with an integrated,  fully managed, Ethernet switch, designed to operate reliably in electrically harsh and climatically  demanding environments. Featuring a modular design that can support up to 16 serial ports and up  to 4 Ethernet ports, the RS416 is able to interconnect multiple types of intelligent electronic devices  (IEDs) that have different methods of communications.
                    
                    ページ7に含まれる内容の要旨 
                    
                        • Integrated Ethernet Switch - 2 or 4 port options  • (copper and/or fiber)  • High performance and throughput Ethernet switching  • Fully IEEE 802.3, IEEE 802.3u, IEEE 802.3x compliance  • Non-blocking, store and forward switching    RuggedRated™ for Reliability in Harsh Environments  • Immunity to EMI and heavy electrical surges  • Meets IEEE 1613 (electric utility substations)  • Exceeds IEC 61850-3 (electric utility substations)  • Exceeds IEC 61800-3 (variable speed drive systems)  • Exceed
                    
                    ページ8に含まれる内容の要旨 
                    
                          3.3 Display Panel Description    The RS416 is equipped with a versatile display panel, shown in Figure 1, which is designed to  provide quick status information for each port, as well as the entire device to allow for simple  diagnostics and troubleshooting. It features:    • RS232 console port for ‘out of band’ console access and configuration  • Power supply and Alarm status indicators  • Convenient port status indicators conveying Link-Activity, Duplex, or Speed via push- button control.  •
                    
                    ページ9に含まれる内容の要旨 
                    
                        The port-based LEDs can be cycled between three display modes:  Status, Duplex, and Speed.   Pushing the mode button causes the display mode to be cycled.  Table 2 and Table 3 define the  possible port LED colours and the corresponding description.    Ethernet Port Status Serial Port Status  Mode Colour  LEDs LEDs  Green (Solid) Link -  Status Green (Blinking) Activity Traffic  Off No link No Traffic  Green (Solid) Full-Duplex  Full-Duplex  Duplex Orange (Solid) Half-Duplex Half-Duplex  Off No l
                    
                    ページ10に含まれる内容の要旨 
                    
                        4 Installation  4.1 Mounting    The RS416 has been designed with maximum mounting and display flexibility.  Customers can  order an RS416 that can be mounted in a standard 19” rack, 1” DIN Rail, or directly onto a panel.   For rack mount installations, the RS416 can be ordered with connectors on the front of the unit, or  located on the rear of the chassis to allow for all data and power cabling to be installed and  connected at the rear of the rack. See Figure 2 for rack mount orientation examp
                    
                    ページ11に含まれる内容の要旨 
                    
                        4.1.1 Rack Mounting    The RS416 can be rack mounted using the included rack mount adapter assemblies shown in  Figure 3.  Secure the one rack mount adapter to the front of each side of the chassis using the  included black PAN head Philips screws in the positions shown in Figure 4. The entire chassis can  then be mounted to a standard 19” rack. An additional two rack mount adapters are included to  optionally secure the rear of the chassis in high-vibration, or seismically active locations.    
                    
                    ページ12に含まれる内容の要旨 
                    
                        4.1.2 Panel and DIN Rail Mounting    The RS416 can be ordered as a Panel/DIN mount chassis. Both options involve the use of the  panel/DIN adapters to be mounted on each side of the chassis enclosure. The adapter allows the  chassis to be mounted on the standard 1” DIN rail using the grooves in the adapter, secured using  the included Philips screw. See Figure 5 for a PANEL/DIN mount diagram.      Figure 5:  RS416 Series PANEL/DIN RAIL mounting diagram with       12   2008 RuggedCom Inc. All ri
                    
                    ページ13に含まれる内容の要旨 
                    
                        4.2 Power Supply Wiring and Grounding    Philips Screw Terminal with Cover Philips Screw Terminal without Cover Safety Cover Chassis Ground Surge / Chassis Terminal Safety Cover Screws Connection Ground Jumper Figure 6: RS416 Series Philips Screw Terminal Block      Phoenix Plug Terminal with Cover Phoenix Plug Terminal without Cover Safety Cover  Surge / Chassis  Safety Cover Chassis Ground Terminal Screws Ground Jumper Connection Figure 7: RS416 Series Phoenix Plug Terminal Block    The RS416 
                    
                    ページ14に含まれる内容の要旨 
                    
                          Terminal # Description Usage  PS1 Live / + is connected to the positive (+) terminal if the  1 PS1 Live / + power source is DC or to the (Live) terminal if the power  source is AC.  PS1 Surge Ground is connected to the Chassis Ground via  a jumper on the terminal block. Surge Ground is used as the  2 PS1 Surge Ground  ground conductor for all surge and transient suppression  circuitry.   PS1 Neutral / - is connected to the negative (-) terminal if  3 PS1 Neutral / -  the power source is DC or 
                    
                    ページ15に含まれる内容の要旨 
                    
                        4.2.1 AC Power Supply Wiring Examples      Figure 8: AC Power supply wiring examples    NOTES:  1. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be  installed within 3m of unit.  2. Equipment must be installed according to the applicable country wiring codes.  3. When equipped with two HI voltage power supplies, independent AC sources can be used  to power the product for greater redundancy. However, separate circuit breakers must be  installed and separately iden
                    
                    ページ16に含まれる内容の要旨 
                    
                        4.2.2 DC Power Supply Wiring Examples      Figure 9:  DC Power supply wiring examples    NOTES:  1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be  installed within 3m of unit.  2. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.  3. Equipment must be installed according to the applicable country wiring codes.  4. When equipped with two HI voltage power supplies, independent AC sources can be  used to power the product for greater redu
                    
                    ページ17に含まれる内容の要旨 
                    
                        4.2.3 Dual Power Supplies Wiring Examples      Figure 10:  DC And AC power supply wiring examples    NOTES:  1. 88-300VDC rated equipment: A 300VDC appropriately rated circuit breaker must be  installed within 3m of unit.  2. 100-240VAC rated equipment: A 250VAC appropriately rated circuit breaker must be  installed within 3m of unit.  3. A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.  4. Separate circuit breakers must be installed and separately identified.  5. Equ
                    
                    ページ18に含まれる内容の要旨 
                    
                        4.3 Dielectric Strength (HIPOT) Testing    For dielectric strength (HIPOT) testing in the field, users must remove the metal jumper located on  terminal 2, 4, and 6 of the power supply terminal block.  This metal jumper connects transient  suppression circuitry to chassis ground and must be removed in order to avoid damage to transient  suppression circuitry during HIPOT testing.  Figure 11 shows the proper HIPOT test connections  and should be followed to avoid damage to the device.        Figu
                    
                    ページ19に含まれる内容の要旨 
                    
                        4.4 Failsafe Alarm Relay Wiring    The “Failsafe” output relay is provided to signal critical error conditions that may occur on the  RS416. The contacts are energized upon power up of the unit and remain energized until a critical  error occurs. The proper relay connections are shown in Figure 12. One common application for  this output is to signal an alarm if a power failure or removal of control power occurs. The failsafe  relay current and power handling capabilities are defined in       Fi
                    
                    ページ20に含まれる内容の要旨 
                    
                        4.5 Console Port Wiring    A RS232 console port for configuration and management of the device is located on the LED  display module shown in Figure 13. This port is intended to be a temporary connection during initial  configuration or troubleshooting and allows for direct access to the serial-based management  console. The connection is made using the DB9-Female to RJ45 console cable included in the  device packaging shown below. Console connection settings are 57600 baud, no parity bits, 8 da