Switch                                                                                                                                                                                                                                                                                                                                                                                                   
                    
                    ページ2に含まれる内容の要旨 
                    
                        TigerStack II 10/100/1000 Installation Guide From SMC's Tiger line of feature-rich workgroup LAN solutions 20 Mason August 2009 Irvine, CA 92618 Pub. # 150200000054A  Phone: (949) 679-8000 E082009-MW-R01                                                                                                                                                                                                                                                                                                         
                    
                    ページ3に含まれる内容の要旨 
                    
                        Information furnished by SMC Networks, Inc. (SMC) is believed to be accurate and  reliable. However, no responsibility is assumed by SMC for its use, nor for any  infringements of patents or other rights of third parties which may result from its use. No  license is granted by implication or otherwise under any patent or patent rights of SMC.  SMC reserves the right to change specifications at any time without notice. Copyright © 2009 by SMC Networks, Inc. 20 Mason Irvine, CA 92618 All rights re
                    
                    ページ4に含まれる内容の要旨 
                    
                          Warranty and Product Registration To register SMC products and to review the detailed warranty statement, please refer to  the Support Section of the SMC Website at http://www.smc.com.                                                                                                                                                                                                                                                                                                                          
                    
                    ページ5に含まれる内容の要旨 
                    
                        Compliances and Safety Warnings FCC - Class A This equipment has been tested and found to comply with the limits for a Class A digital  device, pursuant to part 15 of the FCC Rules. These limits are designed to provide  reasonable protection against harmful interference when the equipment is operated in a  commercial environment. This equipment generates, uses, and can radiate radio  frequency energy and, if not installed and used in accordance with the instruction manual,  may cause harmful int
                    
                    ページ6に含まれる内容の要旨 
                    
                          CE Mark Declaration of Conformance for EMI and Safety (EEC) This information technology equipment complies with the requirements of the Council  Directive 89/336/EEC on the Approximation of the laws of the Member States relating to  Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain  voltage limits and the Amendment Directive 93/68/EEC. For the evaluation of the  compliance with these Directives, the following standards were applied: RFI Emission: • Limit 
                    
                    ページ7に含まれる内容の要旨 
                    
                        Safety Compliance Warning: Fiber Optic Port Safety When using a fiber optic port, never look at the transmit laser while it is  CLASS I powered on. Also, never look directly at the fiber TX port and fiber cable  LASER DEVICE ends when they are powered on. Avertissment: Ports pour fibres optiques - sécurité sur le plan optique Ne regardez jamais le laser tant qu'il est sous tension. Ne regardez  DISPOSITIF LASER jamais directement le port TX (Transmission) à fibres optiques et les  DE CLASSE I em
                    
                    ページ8に含まれる内容の要旨 
                    
                          Important! Before making connections, make sure you have the correct cord set. Check  it (read the label on the cable) against the following:  Power Cord Set U.S.A. and Canada The cord set must be UL-approved and CSA certified. The minimum specifications for the flexible cord are:  - No. 18 AWG - not longer than 2 meters, or 16 AWG.  - Type SV or SJ  - 3-conductor The cord set must have a rated current capacity of at least 10 A The attachment plug must be an earth-grounding type with NEMA  5-1
                    
                    ページ9に含まれる内容の要旨 
                    
                        France et Pérou uniquement:  Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos  alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une  tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec  un point secondaire de connexion portant l’appellation Neutre et avec raccordement  direct à la terre (masse). Cordon électrique - Il doit être agréé dans le pays d’utilisation Etats-Unis et Le cordon doit a
                    
                    ページ10に含まれる内容の要旨 
                    
                          Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden:  Schweiz Dieser Stromstecker muß die SEV/ASE 1011Bestimmungen ein- halten. Europe Das Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung)  sein und die Aufschrift  oder  tragen. Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”). Warnings and Cautionary Messages Warning: This product does not contain any serviceable user parts. Warning: Installation and removal of the unit must be carried out by qu
                    
                    ページ11に含まれる内容の要旨 
                    
                        Documentation All printed documentation for this product uses biodegradable paper that originates from  sustained and managed forests. The inks used in the printing process are non-toxic. vii                                                                                                                                                                                                                                                                                                                     
                    
                    ページ12に含まれる内容の要旨 
                    
                        About This Guide Purpose This guide details the hardware features of this device, including the physical and  performance-related characteristics, and how to install it. Audience The guide is intended for use by network administrators who are responsible for installing  and setting up network equipment; consequently, it assumes a basic working knowledge  of LANs (Local Area Networks). Conventions The following conventions are used throughout this guide to show information: Note: Emphasizes impor
                    
                    ページ13に含まれる内容の要旨 
                    
                        Contents    Chapter 1: Introduction 1-1 Overview 1-1 Switch Architecture 1-2 Network Management Options 1-2 Description of Hardware 1-3 10/100/1000BASE-T Ports 1-3 SFP Slots 1-3 10 Gigabit Ethernet Module Slots 1-3 Stacking Ports 1-3 Port and System Status LEDs 1-3 Optional Redundant Power Supply 1-5 Power Supply Sockets 1-5 Optional Media Extender Modules 1-6 Extender Module LEDs 1-6 Features and Benefits 1-7 Connectivity 1-7 Expandability 1-7 Performance 1-7 Management 1-7 Chapter 2: Network P
                    
                    ページ14に含まれる内容の要旨 
                    
                        Contents Desktop or Shelf Mounting 3-4 Installing an Optional Module into the Switch 3-5 Installing an Optional SFP Transceiver 3-6 Connecting Switches in a Stack 3-7 Stacking Topologies 3-8 Connecting to a Power Source 3-8 Connecting to the Console Port  3-9 Wiring Map for Serial Cable 3-9 Chapter 4: Making Network Connections 4-1 Connecting Network Devices 4-1 Twisted-Pair Devices 4-1 Cabling Guidelines 4-1 Connecting to PCs, Servers, Hubs and Switches 4-2 Network Wiring Connections 4-2 Fiber 
                    
                    ページ15に含まれる内容の要旨 
                    
                        Contents Appendix C: Specifications C-1 Physical Characteristics C-1 Switch Features C-3 Management Features C-3 Standards C-3 Compliances C-4 Extender Modules C-4 10GBASE Extender Module (XFP) C-4 Glossary Index xi                                                                                                                                                                                                                                                                                             
                    
                    ページ16に含まれる内容の要旨 
                    
                        Tables Table 1-1 Port Status LEDs 1-4 Table 1-2 System Status LEDs 1-4 Table 1-3 Supported XFP Transceivers 1-6 Table 1-4 Module LEDs 1-6 Table 3-1 Serial Cable Wiring 3-9 Table 4-1 Maximum 10GBASE-SR 10 Gigabit Ethernet Cable Length 4-6 Table 4-2 Maximum 10GBASE-LR 10 Gigabit Ethernet Cable Length 4-6 Table 4-3 Maximum 10GBASE-ER 10 Gigabit Ethernet Cable Length 4-6 Table 4-4 Maximum 1000BASE-T Gigabit Ethernet Cable Length 4-7 Table 4-5 Maximum 1000BASE-SX Gigabit Ethernet Cable Length 4-7 Tab
                    
                    ページ17に含まれる内容の要旨 
                    
                        Figures Figure 1-1 Front Panels 1-1 Figure 1-2 Rear Panel 1-2 Figure 1-3 Port LEDs 1-4 Figure 1-4 System LEDs 1-4 Figure 1-5 Power Supply Sockets 1-5 Figure 1-6 Single-Port 10GBASE Module (XFP) 1-6 Figure 2-1 Collapsed Backbone 2-2 Figure 2-2 Network Aggregation Plan 2-3 Figure 2-3 Remote Connections with Fiber Cable 2-4 Figure 2-4 Making VLAN Connections 2-5 Figure 2-5 IP Routing for Unicast Traffic 2-6 Figure 3-1 RJ-45 Connections 3-2 Figure 3-2 Attaching the Brackets 3-3 Figure 3-3 Installing
                    
                    ページ18に含まれる内容の要旨 
                    
                        Figures xiv                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         
                    
                    ページ19に含まれる内容の要旨 
                    
                        Chapter 1: Introduction Overview The SMC8926EM and SMC8950EM are intelligent multilayer switches (Layer 2, 3)  * with 24/48 10/100/1000BASE-T ports, four of which are combination ports that are  shared with four SFP transceiver slots (see Figure 1-1, Ports 21-24/45-48). The rear  panel provides two slots for single-port 10 Gigabit Ethernet hot-swappable  expansion modules, and two stacking ports. Units can be stacked up to eight high  through the built-in stacking ports that provide a 50 Gbps st
                    
                    ページ20に含まれる内容の要旨 
                    
                        Introduction 1 PowerSocket RedundantPowerSocket ModuleSlots StackingPorts Figure 1-2  Rear Panel Switch Architecture These Gigabit Ethernet switches employ a wire-speed, non-blocking switching  fabric. This permits simultaneous wire-speed transport of multiple packets at low  latency on all ports. The switches also feature full-duplex capability on all ports,  which effectively doubles the bandwidth of each connection. For communications between different VLANs, these switches use IP routing. Fo