ページ1に含まれる内容の要旨 
                    
                        Centrifugal Roof Downblast Exhaust Fans 
• General Clean Air   • Light Contaminants    
• Seismic   • High Wind   • Variable Volume     
Models G and GB 
Performance data now included.
June
2011                                                                                                                                                                                                                                                                                                                  
                    
                    ページ2に含まれる内容の要旨 
                    
                        Models G and GB   Spun Aluminum • Downblast   Centrifugal Roof Exhaust Fans PERFORMANCE AND DIMENSIONS: Contents Model Comparison . . . . . . . . . . . . . . . . . . . . . 3 . Models G-060-095  . . . . . . . . . . . . . . . . . . 14-17  Models G-097-G203 . . . . . . . . . . . . . . . . . 18-31 Construction Features . . . . . . . . . . . . . . . . . 4-5  GB-071-200 . . . . . . . . . . . . . . . . . 18-32 Emergency Smoke Control  . . . . . . . . . . . . . . 6 . Models  GB-220-540 . . . . . . . . .
                    
                    ページ3に含まれる内容の要旨 
                    
                        Models G and GB   Spun Aluminum • Downblast   Centrifugal Roof Exhaust Fans Model Comparison Drive Impeller  Performance Location Mounting Airflow Application Type Type Model G 6,308 1 .5 $         GB 44,700 3 .25 $           *High wind limited to sizes 300 and smaller **Smoke Control available on models:  101, 101HP, 121, 131, 141, 141HP, 161, 161HP, 200, 240, 300, 360, 420 and 480 . Greenheck models G and GB centrifugal roof  exhaust provide the industry’s best performance and
                    
                    ページ4に含まれる内容の要旨 
                    
                        Construction Features   Models G and GB Standard Construction Features An aluminum, backward-inclined, non-overloading centrifugal wheel is utilized to  generate high-efficiency and minimal sound . Wheel cones are carefully matched to  Wheel 1 the venturi for maximum efficiency. Each wheel is robotically welded and statically  and dynamically balanced for long life and quiet operation . NEMA-1 switch is factory mounted and wiring is provided from the motor as standard  Disconnect  (other switche
                    
                    ページ5に含まれる内容の要旨 
                    
                        Construction Features   Models G and GB 6 7 5 15 1 11 14 12 8 MODEL G DIRECT DRIVE 8 DRIVE FRAME (BELT DRIVE) 3 10 4 8 16 2 9 13 18 19 MODEL GB BELT DRIVE 17 5                                                                                                                                                                                                                                                                                                                                                     
                    
                    ページ6に含まれる内容の要旨 
                    
                        Applications   G and GB models Emergency Smoke Control - GB When you buy a Greenheck • UL/cUL Listed for 500°F (260°C) for 4 hours and  model GB with the smoke 1,000°F (538°C) for 15 minutes . control option, you receive a  • Half the weight of traditional smoke control fans,  fan with the industry’s best  ideal choice for roof load concerns . performance and durability for  • Low profile, height is less than half of traditional  smoke control applications (as  1 smoke control fans, maximum of 5
                    
                    ページ7に含まれる内容の要旨 
                    
                        Applications  G and GB models High Wind and Hurricane - G and GB Greenheck is leading the High Wind Standard for roof top fans and  ventilators. Forceful winds and wind-borne debris are the cause of  most hurricane damage. Hurricane winds start at 75 mph. At speeds  over 150 mph, wind can exert a force of 75 pounds per square foot  of pressure or over 900 pounds on a fan and curb. Forceful winds are  not the only problem, wind-borne debris can also cause detrimental  effects to objects and struc
                    
                    ページ8に含まれる内容の要旨 
                    
                        Options • Direct drive fans are often preferred where  ™ Vari-Green Motor - Model G  maintenance access is difficult . Greenheck’s electronically commutated  • The Vari-Green motor reduces noise and vibration  Vari-Green™ (VG) motor combines motor  as well as providing solutions for variable volume  technology, controllability and energy- system balancing . efficiency into one single low maintenance unit and  Features is the industry’s first fully controllable motor . When  combined with Greenhe
                    
                    ページ9に含まれる内容の要旨 
                    
                        Options Example: Initial Cost Comparison Belt Drive vs. Direct Drive Vari-Green Demand Control Ventilation  for multi-story buildings  GB-121 Applications requiring constant pressure  control or variable volume as used in  G-123-VG multi-storied buildings such as hotels,  multi-family complexes, institutional  $0 100 200 300 400 500 600 700  facilities, and high rise commercial buildings,   Fan Price                       VFD Price may utilize G fans with Vari-Green™ motor and   The diagram show
                    
                    ページ10に含まれる内容の要旨 
                    
                        Options and Accessories Roof Curbs High Wind and Severe Duty Roof Curbs  Prefabricated roof curbs reduce installation time Provided as an option with models G and GB. The  and costs by ensuring compatibility between severe-duty roof curb models can ship separately  the fan, the curb and roof opening . All curbs are to allow for final finishing of the roof prior to the fan  insulated with fiberglass. A wide variety of roof arrival and installation . curbs are available, including: flanged, pitche
                    
                    ページ11に含まれる内容の要旨 
                    
                        Options and Accessories Speed Controllers for   Coatings  Standard Motors A wide variety of coatings and colors are available.  Available for use with shaded   Greenheck coatings and resistance charts can be  pole and permanent split   found in the Performance Coatings Commercial   capacitor (PSC) open motors   and Industrial Fans catalog and in our Product  on model G fans . They provide  Application Guide—Performance Coatings for  an economical means of system   Ventilation Products . balancin
                    
                    ページ12に含まれる内容の要旨 
                    
                        Typical Installations Models G and GB General Clean Air (figure 1) Factory Wired from Motor to Disconnect Models G and GB exhaust fans are designed to   meet the needs of general clean air applications .  Tests were conducted to assure safe, rugged and  reliable fans . Due to the varying types of airstreams encountered  in commercial ventilation, system designers must  be aware of national, state, and local codes and  figure 1 guidelines governing these installations . Local code  authorities sh
                    
                    ページ13に含まれる内容の要旨 
                    
                        Typical Installations Models G and GB Fan Inlet Connections In order to assure proper fan performance, caution  must be exercised in fan placement and connection  Good to the ventilation system . Obstructions, transitions,  Good poorly designed elbows, improperly selected  dampers, etc ., can cause reduced performance,  excessive noise, and increased mechanical stress .  For performance to be as published, the system  must provide uniform and stable airflow into the fan. A B Provide uniform airf
                    
                    ページ14に含まれる内容の要旨 
                    
                        Roof Downblast - Exhaust  Direct Drive G-060 • G-065 3 19 ⁄8  RPM (Direct)  3 Density  0.075 lb/ft (492) 3 Density  1.2 kg/m 1   *12 ⁄8 (308) 3 (76) 3 1 ⁄4 (44) 17  (432) Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) Volume (cfm) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thickness = 0.064 (1.6) Volume (m /hr ) ^Approximate Unit Weight = 15 lbs. (7 kg) Direct Drive RPM All dimensions in inches (millimeters) . *May be greater depending
                    
                    ページ15に含まれる内容の要旨 
                    
                        Roof Downblast - Exhaust Direct Drive G-070 • G-075 3 RPM (Direct) 19 ⁄8  3 Density  0.075 lb/ft (492) 3 Density  1.2 kg/m 1 *12 ⁄8  (308) 3 (76) 3 1 ⁄4 (44) 17  (432) Damper Size = 8 x 8 (203 x 203) Roof Opening = 101/2 x 101/2 (267 x 267) Volume (cfm) Shroud Thickness = 0.064 (1.6) Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thickness = 0.064 (1.6) /hr ) Volume (m ^Approximate Unit Weight = 15 lbs. (7 kg) Direct Drive RPM All dimensions in inches (millimeters) . *May be greater depending on
                    
                    ページ16に含まれる内容の要旨 
                    
                        080-D   080-G  080-VG  080-E  085-E  085-D  085-G  085-VG  Roof Downblast - Exhaust  Direct Drive G-080 • G-085 3 21 ⁄4 0.9 220 (552)  RPM (Direct Drive)  RPM (Vari Green) 200 0.8 3 Density 0.075 lb/ft 3 Density  1.2 kg/m 180 0.7 160 0.6 5 ⁄8  *14 140 (371) 0.5 120 100 0.4 4 (102) 80 0.3 3 1 ⁄4 (44) 60    17 0.2 (432) 40 0.1 20 0 0.0 0 100 200 300 400 500 600 Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 (318 x 318) Volume (cfm) Shroud Thickness = 0.064 (1.6) 0 100 200 300 400 5
                    
                    ページ17に含まれる内容の要旨 
                    
                         090-E  090-G  095-E  090-D  090-VG  095-G  095-D 095-VG  Roof Downblast - Exhaust  Direct Drive G-090 • G-095 3 21 ⁄4  1.0 (552)  RPM  RPM (Vari Green) 3 Density 0.075 lb/ft 3 Density  1.2 kg/m 200 0.8 5 ⁄8  *14 150 0.6 (371) 4 (102) 100 0.4 3 1 ⁄4 (44)    17  50 0.2 (432) 0 0.0 0 200 400 600 800 1000 1200 Damper Size = 10 x 10 (254 x 254) Roof Opening = 121/2 x 121/2 318 x 318) ( Volume (cfm) Shroud Thickness = 0.064 (1.6) 0 500 1000 1500 2000 Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thi
                    
                    ページ18に含まれる内容の要旨 
                    
                        Roof Downblast Exhaust  Belt & Direct Drive  GB-071 • G-097 3 24 ⁄8   RPM (Belt) (619)  RPM (Direct)  RPM (Vari-Green)  HP 3 Density  0.075 lb/ft 3 Density  1.2 kg/m 3 ⁄4  *23 (603) 3 4 ⁄8 (111) 3 1 ⁄4 (44) 19 (483) Damper Size = 12 x 12 (305 x 305) Roof Opening = 141/2 x 141/2 (368 x 368) Volume (cfm) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) 3 Curb Cap Thickness = 0.064 (1.6) Volume (m /hr ) ^Approximate Unit Weight G/GB = 54/60 lbs. (24/27 kg) Direct Drive RPM All dim
                    
                    ページ19に含まれる内容の要旨 
                    
                        Roof Downblast Exhaust  Belt & Direct Drive   GB-081 • G-098 3 24 ⁄8   RPM (Belt) (619)  RPM (Direct)  RPM (Vari-Green)  HP 3 Density  0.075 lb/ft 3 Density  1.2 kg/m 3 ⁄4  *23 (603) 3 4 ⁄8 (111) 3 1 ⁄4 (44) 19  (483) Damper Size = 12 x 12 (305 x 305) Volume (cfm) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) 3 Volume (m/hr ) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight G/GB = 54/60 lbs. (24/27 kg) Direct Drive RPM All di
                    
                    ページ20に含まれる内容の要旨 
                    
                        Roof Downblast Exhaust  Belt & Direct Drive  GB-091 • G-099 3 24 ⁄8   RPM (Belt) (619)  RPM (Direct)  RPM (Vari-Green)  HP 3 Density  0.075 lb/ft 3 Density  1.2 kg/m 3 ⁄4  *23 (603) 3 4 ⁄8 (111) 3 1 ⁄4 (44) 19  (483) Damper Size = 12 x 12 (305 x 305) Volume (cfm) Roof Opening = 141/2 x 141/2 (368 x 368) Shroud Thickness = 0.051 (1.3) Motor Cover Thickness = 0.040 (1.0) 3 Volume (m /hr ) Curb Cap Thickness = 0.064 (1.6) ^Approximate Unit Weight G/GB = 54/61 lbs. (24/28 kg) Direct Drive RPM All di