ページ1に含まれる内容の要旨 
                    
                         
 
 
 
 
 
USER’S GUIDE 
Agilent Technologies 
Model 66319B/D, 66321B/D 
Mobile Communications DC Source 
 
 
 
Featuring programmable output resistance 
 (Refer to page 20 for a brief description of the model differences.) 
 
 
 
 
 
 
 
 
 
 
 
 
Agilent Part No. 5964-8184 
Microfiche No. 5964-8185 
Printed in Malaysia:  May, 2003                                                                                                                                                                     
                    
                    ページ2に含まれる内容の要旨 
                    
                        Warranty Information  CERTIFICATION  Agilent Technologies certifies that this product met its published specifications at time of shipment from the factory.  Agilent Technologies further certifies that its calibration measurements are traceable to the United States National  Bureau of Standards, to the extent allowed by the Bureau's calibration facility, and to the calibration facilities of other  International Standards Organization members.  WARRANTY  This Agilent Technologies hardware product
                    
                    ページ3に含まれる内容の要旨 
                    
                        Safety Summary  The following general safety precautions must be observed during all phases of operation of this instrument.  Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety  standards of design, manufacture, and intended use of the instrument. Agilent Technologies assumes no liability  for the customer's failure to comply with these requirements.  GENERAL  This product is a Safety Class 1 instrument (provided with a protective  earth t
                    
                    ページ4に含まれる内容の要旨 
                    
                          SAFETY SYMBOLS  Direct current    Alternating current    Both direct and alternating current    Three-phase alternating current    Earth (ground) terminal    Protective earth (ground) terminal    Frame or chassis terminal    Terminal is at earth potential. Used for measurement and control circuits designed to be  operated with one terminal at earth potential.    Terminal for Neutral conductor on permanently installed equipment    Terminal for Line conductor on permanently installed equipment  
                    
                    ページ5に含まれる内容の要旨 
                    
                        Declaration Page    DECLARATION OF CONFORMITY  according to ISO/IEC Guide 22 and EN 45014         Manufacturer's Name: Agilent Technologies, Inc.    Manufacturer's Address: 140 Green Pond Road     Rockaway, New Jersey  07866     U.S.A.     declares that the Product        Product Name: a) Dynamic Measurement DC Source     b) System DC Power Supply     c) Remote Front Panel      Model Number: a) Agilent 66311B, 66311D, 66312A, 66111A, 66321B, 66321D      b) Agilent 6612B, 6611C, 6612C, 6613C, 661
                    
                    ページ6に含まれる内容の要旨 
                    
                          DECLARATION OF CONFORMITY  according to ISO/IEC Guide 22 and EN 45014         Manufacturer's Name: Agilent Technologies, Inc.    Manufacturer's Address: 140 Green Pond Road     Rockaway, New Jersey  07866     U.S.A.     declares that the Product        Product Name: a) Mobile Communication DC Source-Dual Output      Model Number: a) Agilent 66319B, 66319D          conforms to the following Product Specifications:      Safety: IEC 1010-1:1990+A1(1992)/EN61010-1:1993      EMC: CISPR 11:1990 / EN
                    
                    ページ7に含まれる内容の要旨 
                    
                        Acoustic Noise Information  Herstellerbescheinigung  Diese Information steht im Zusammenhang mit den Anforderungen der  Maschinenläminformationsverordnung vom 18 Januar 1991.   * Schalldruckpegel Lp <70 dB(A)   * Am Arbeitsplatz    * Normaler Betrieb   * Nach EN 27779 (Typprüfung).  Manufacturer's Declaration  This statement is provided to comply with the requirements of  the German Sound Emission Directive,  from 18 January 1991.   * Sound Pressure Lp  <70 dB(A)   * At Operator Position   * Nor
                    
                    ページ8に含まれる内容の要旨 
                    
                        Table of Contents  Warranty Information 2  Safety Summary 3  Declaration Page 5  Acoustic Noise Information 7  Printing History 7  Table of Contents 8    1 - QUICK REFERENCE 11  The Front Panel - At a Glance 11  The Rear Panel - At a Glance 12  Instrument Configuration 12  Front Panel Number Entry 13  Front Panel Annunciators 14  Immediate Action Keys 14  Front Panel Menus - At a Glance 15  SCPI Programming Commands - At a Glance 16    2 - GENERAL INFORMATION 17  Document Orientation 17  Safety 
                    
                    ページ9に含まれる内容の要旨 
                    
                        Types of SCPI Messages 65  SCPI Data Formats 67  SCPI Command Completion 68  Using Device Clear 68  SCPI Conformance Information 69    7 - PROGRAMMING THE DC SOURCE 71  Introduction 71  Programming the Output 71  Triggering Output Changes 73  Making Basic Measurements 75  Making Enhanced Measurements 76  Making DVM Measurements 79  Triggered Measurements 80  Programming the Status Registers 84  Inhibit/Fault Indicator 89    8 - LANGUAGE DICTIONARY 91  Introduction 91  Calibration Commands 96  Di
                    
                    ページ10に含まれる内容の要旨 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ11に含まれる内容の要旨 
                    
                          1  Quick Reference  The Front Panel - At a Glance  1 A 14-character display  2 Annunciators indicate 3 Rotary control sets voltage,  shows output measurements  operating modes and status current, and menu parameters.  and programmed values.  conditions.  " " ! !  " " ! ! Use           and  to set the resolution; then adjust  the value with the knob.  1 2 3 66319D                   DUAL OUTPUT Mobile Communications DC Source CV CC Unr Dis OCP Prot Cal Shift Rmt Addr Err SRQ SYSTEM FUNCTION ENTR
                    
                    ページ12に含まれる内容の要旨 
                    
                        1 - Quick Reference  The Rear Panel - At a Glance  1 DVM inputs. 2 GPIB (IEEE-488) 3 Used to connect the 4 INH/FLT connector. Can  Connector plug is interface connector. Agilent 14575A remote be configured for Digital I/O  removable. front panel display. and Trigger input. Connector  plug is removable.  2 3 4 1 NO OPERATOR SERVICEABLE PARTS REFER SERVICING TO SERVICE TRAINED WARNING: INH FLT +- + - +  ! DVM       OUTPUT 2    OUTPUT 1 0 - 12V / 0 - 1.5A 0 - 15V / 0 - 3A -S -S +S +S -+ - + FOR CON
                    
                    ページ13に含まれる内容の要旨 
                    
                        Quick Reference - 1  Front Panel Number Entry  Enter numbers from the front panel using one the following methods:  Use the arrow keys and knob to change voltage or current settings  NOTE: The output must be ON to see the displayed values change in Meter mode. With the  output enabled, this method changes the output voltage or current immediately.    Use the Function keys and knob to change the displayed settings    Use the arrow keys to edit individual digits in the displayed setting   Incremen
                    
                    ページ14に含まれる内容の要旨 
                    
                        1 - Quick Reference  Front Panel Annunciators      CV Output 1 or output 2 is operating in constant voltage mode.  CC Output 1 or output 2 is operating in constant current mode.  Unr Output 1 or output 2 is unregulated.  The output is OFF. Press the Output On/Off  key to turn the output on.  Dis  The over-current protection state is ON. Press the OCP key to turn over-current  OCP  protection off.  Indicates that the output has been disabled by one of the protection features.  Prot  Press the Pro
                    
                    ページ15に含まれる内容の要旨 
                    
                        Quick Reference - 1  Front Panel Menus - At a Glance    Address   Sets the GPIB Address  ADDRESS 7  $$   $$ Selects language (SCPI)   LANG SCPI  $$$$   REMOTE FP OFF Enables or disables Agilent 14575A remote front panel (ON | OFF)  $$$$   ROM: A.00.00 Displays the firmware revision of the instrument  $$$$   SN:  US12345678 Displays the serial number of the instrument  Recall   Recalls the instrument state  *RCL 0  Shift Save   *SAV 0 Saves the present instrument state  Shift Error   Displays the
                    
                    ページ16に含まれる内容の要旨 
                    
                        1 - Quick Reference  SCPI Programming Commands - At a Glance  NOTE: Some [optional] commands have been included for clarity. Refer to chapter 8 for a  complete description of all programming commands.     ABORt SENSe  CALibrate  :CURRent :RANGe    :CURRent [:POSitive]   :DETector ACDC | DC          :MEASure :LOWRange  :FUNCtion  “VOLT” | “CURR” | "DVM"      :R3  :LEAD :STATus?      :AC  :PROTection :STATe   1  :CURRent2   :SWEep :OFFSet :POINts    :DATA        :POINts    :DATE 
                    
                    ページ17に含まれる内容の要旨 
                    
                          2  General Information  Document Orientation  This manual describes the operation of the Agilent Model 66321B/D Mobile Communications and the  Agilent Model 66319B/D Dual Output DC Source. Agilent Models 66321D and 66319D have an  additional DVM measurement input on the rear panel. Unless otherwise noted, all models will be  referred to by the description "dc source" throughout this manual.   The following Getting Started Map will help you find the information you need to complete the specific
                    
                    ページ18に含まれる内容の要旨 
                    
                        2 - General Information  Safety Considerations  This dc source is a Safety Class 1 instrument, which means it has a protective earth terminal. That  terminal must be connected to earth ground through a power source equipped with a ground receptacle.  Refer to the Safety Summary page at the beginning of this guide for general safety information. Before  installation or operation, check the dc source and review this guide for safety warnings and instructions.  Safety warnings for specific procedur
                    
                    ページ19に含まれる内容の要旨 
                    
                        General Information - 2  Description and Model Differences  Agilent 66321B  The Agilent 66321B Mobile Communications DC Source is a high performance dc power source that  provides peak current sourcing and rapid, basic measurements in a compact, half-rack box. It is designed  to simplify the testing of digital wireless communications products. Excellent voltage transient response  characteristics prevent test interruptions due to triggering of low voltage phone shutdown. The 15 volt  source and 
                    
                    ページ20に含まれる内容の要旨 
                    
                        2 - General Information  ! Triggered acquisition of digitized current and voltage waveforms  ! External measurement trigger input on units with firmware revision A.03.01 and up  ♦ Open sense lead protection on output 1.  ♦ Automatic overvoltage protection tracking.  ♦ Over-temperature, RI/DFI protection features, programmable voltage limit and current limit.  ♦ Non-volatile state storage and recall with SCPI command language.  ♦ User-configurable power-on/reset settings (see Appendix B).  Table