                        Monitored Dual Filtration System 
Installation and Operating Instructions 
Model US-1500 (with electronic monitor)
NOTE: 
Specifications
• For cold water use only.
Temperature Range: 40–100°F (4.4–37.8°C)
• M ake certain that installation complies with all state and local 
Pressure Range: 30–125 psi (2.1–8.62 bar)
laws and regulations.
Service Flow Rate @ 60 psi (4.1 bar): 0.6 gpm (2.3 L/min)
• T he contaminants or other substances removed or reduced by 
Rated Service Life: 1,000 gallons (3,785L)
                    
                    ページ2に含まれる内容の要旨 
                    
                        I n s t a l l a t i o n B • F or standard under-sink installation on 1/2"-14 NPS threads (most common  1 thread on kitchen faucets) cold water line. •  Please read all instructions and precautions before installing and using your  Dual Filtration System.  • Numbered diagrams correspond with numbered steps. D 1. Installing the Water Supply Adapter A C The supply adapter fits 1/2"-NPS supply threads. If local codes permit, it may be  used to connect the US-1500 to the cold water supply line. If loc
                    
                    ページ3に含まれる内容の要旨 
                    
                        4. Mounting the System (A) Center system between water supply adapter and drinking water faucet. 4 1  NOTE:  Allow 1 ⁄2" (38 mm) clearance below system for changing filter cartridges. 3 1 (B)  Install mounting screws at least 13 ⁄4" (350 mm) from cabinet floor and 4 ⁄8" (124  B mm) apart. Leave enough space (approximately 1/2" [13 mm]) between the head of  the screw and the wall to slip system onto screws.  (C)  Place system over screws on wall and slide downwards to lock into place. Make  certain
                    
                    ページ4に含まれる内容の要旨 
                    
                        7. Connecting the System (A)  Assemble tubing with system as shown in Fig. 7A, inserting tubing into  7 appropriate inlet or outlet quick-connect fitting until it stops.   NOTE: In some installations, connecting the system to the water supply  adapter and/or drinking water faucet causes the tubing to enter the quick- connect fitting at a sharp angle. This may exert pressure on the quick- connect fitting and cause it to leak. In these situations, you may wish to use  one or both of the quick-connect
                    
                    ページ5に含まれる内容の要旨 
                    
                        Electronic Monitor Operations Filter Cartridge Replacement The US-1500 system includes an electronic monitor that alerts you • F ilter cartridges the US-1500 will last about 1,000 gallons or twelve  when it is time to change your filter cartridges. Both filter cartridges months before they need to be replaced. Filter cartridge life  should be changed at the same time to ensure that the monitor works varies depending on usage, and/or water conditions. Changes in  properly. The monitor measures actu
                    
                    ページ6に含まれる内容の要旨 
                    
                        T r o u b l e s h o o t i n g Leaks: ...between cap and bottom of filter housing Turn off water supply valve and turn on drinking water faucet to  3 release pressure in system. Remove bottom of housing. Clean O-ring  and O-ring groove (located directly beneath threads of housing). 1 Lubricate O-ring with silicone grease and replace securely into  groove. Screw bottom of housing onto cap and hand-tighten. DO NOT  OVER-TIGHTEN. Turn on water supply valve and check for leaks.  6 4 ...on system inlet
                    
                    ページ7に含まれる内容の要旨 
                    
                        Organic Chemicals Included by Surrogate Testing: Performance Data Important Notice: Read this performance data and compare the  Maximum permissible  capabilities of this system with your actual water treatment needs.   Influent Challenge product water  Substance Concentration mg/L concentration mg/L It is recommended that, before installing a water treatment system,  you have your water supply tested to determine your actual water  alachor 0.050 0.001 treatment needs. atrazine 0.100 0.003 benzene
                    
                    ページ8に含まれる内容の要旨 
                    
                        PENTEK LIMITED WARRANTY PENTEK warrants to the purchase. Any replacement prod warranty does not cover: (1)  fi arising from failure to comply party other than PENTEK, (6) problems and/or damage resulting in whole or in part from alteration, modification, repair or attempted alteration, modification or  repair by any party other than PENTEK, (7) noncompliance with applicable codes/ordinances. If a defect in workmanship and/or defective product or part (PENTEK may consider, in good faith, the custome