ページ1に含まれる内容の要旨 
                    
                        OPERATION AND SERVICE ANUAL 
SPECTRUM ANALYZER                                                                                                                                                                                                                                                                                                                                                                                                                                                                      
                    
                    ページ2に含まれる内容の要旨 
                    
                        Hewlett-Packard Company certifies that this product met its published specifications at the time of  shipment from the factory. Hewlett-Packard further certij?es that its calibration measurements are  traceable to the United States National Bureau of Standards, to the extent allowed by the Bureau's  calibration facility. and to the calibration facilities of other International Standards Organization  members.  WARRANTY  This Hewlett-Packard instrument product is warranted against defects in mate
                    
                    ページ3に含まれる内容の要旨 
                    
                        HEWLETT  PACKARD  OPERATION AND SERVICE MANUAL  8559A  SPECTRUM ANALYZER  0.1 - 21 GHz  SERIAL NUMBERS  This manual applies directly to instruments with  serial numbers prefixed 2347A.  With modifications described in Section VII, this  manual also applies to instruments with serial num-  ber prefixes 1909A through 2320A.  For additional information about serial numbers, see  INSTRUMENTS COVERED BY MANUAL in  Section I.  COPYRIGHT O HEWLETT-PACKARD COMPANY, 1979,1983  1424 FOUNTAINGROVE PARKWAY,
                    
                    ページ4に含まれる内容の要旨 
                    
                        CONTENTS Section Page Section Page 3-29. Display Adjustments-HP 853A I GENERAL INFORMATION . . . . . . . . . . . . . . 1-1 Spectrum Analyzer Display . . . . . . . .3-3 1-1. Introduction . . . . . . . . . . . . . . . . . . . . 1-1 3-30. Display Adjustments-HP 180-Series 1-3. Description . . . . . . . . . . . . . . . . . . . .1-1 Display Mainframe . . . . . . . . . . . . . . 3-3 1-6. Manual Organization . . . . . . . . . . . . . .1-1 3-31. Frequency and Amplitude Adjustments . 3-4 1-9. Specificati
                    
                    ページ5に含まれる内容の要旨 
                    
                        C O N T E N T S Section Page Section Page 5-29. Cal Output and Ref Level Cal VIII SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . 8-1 . . . . . . . . . . . . . . . . . . . . Adjustments . . . . . . . . . . . . . . . . . . 5-66 8-1. Introduction 8-1 8-3. Schematic Symbols, Terminology. 5-30. Frequency Display Adjustments . . . . . . 5-69 and Voltage Levels . . . . . . . . . . . . . . . 8-1 8-5. Test Equipment . . . . . . . . . . . . . . . . . 8-1 VI REPLACEABLE PARTS . . . . . . . . .
                    
                    ページ6に含まれる内容の要旨 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ7に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 8559A  SAFETY SYMBOLS  The following safety symbols are used throughout this manual and in the instrument. Familiarize  yourself with each of the symbols and its meaning before operating this instrument.  Instruction manual symbol. The instrument will be marked with this symbol  when it is necessary for the user to refer to the instruction manual in order to  protect the instrument against damage. Location of pertinent information  within the manual is indicated by use
                    
                    ページ8に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 8559A  SPECTRUM ANALYZER  ADAPTER SIDE STOP KIT OVERLAY KIT  1250-0780 08558-601 31 5060-03 1 9  FIGURE 1-1. HP MODEL8559A SPECTRUM ANALYZER AND ACCESSORIES SUPPLIED  1-0                                                                                                                                                                                                                                                                                                               
                    
                    ページ9に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 8559A  SECTION I  GENERAL INFORMATION  1-1. INTRODUCTION SECTION IV, PERFORMANCE TESTS; con-  tains the necessary tests to verify that the elec-  1-2. This Operation and Service manual contains trical operation of the instrument is in accord-  information required to install, operate, test, adjust, ance with published specifications.  and service the Hewlett-Packard 8559A Spectrum  Analyzer. Figure 1-1 shows the instrument and acces-  SECTION V, ADJUSTMENTS; contains t
                    
                    ページ10に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 8559A  1-1 1. SAFETY CONSIDERATIONS  Manual Updating supplement. This supplement con-  tains change information that explains how to adapt  the manual to the newer instrument.  1-12. Before operating this instrument, you should  familiarize yourself with the safety markings on the  1-18. In addition to change information, the sup-  instrument and safety instructions in this manual.  plement may contain information for correcting  This instrument has been manufactured a
                    
                    ページ11に含まれる内容の要旨 
                    
                        MODEL 8559A GENERAL INFORMATION  HP MODEL8569A SPECIFICATIONS (1 OF 4)  TABLE 1-1.  SPECIFICATIONS  Frequency Readout Resolution  FREQUENCY SPECIFICATIONS  1 MHz  FREQUENCY RANGE  Frequency Span Accuracy  k  5% of displayed frequency separation  10 MHz to 21 GHz, covered in six pushbutton-  selectable ranges:  SPECTRAL RESOLUTION AND STABILITY  Resolution Bandwidths  Lowest Highest  Frequency Mixing  Eight selectable resolution (3-dB) bandwidths in  Freq (GHz)  Band Mode  Freq  1-3 sequence from
                    
                    ページ12に含まれる内容の要旨 
                    
                        GENERAL INFORMATION MODEL 8559A  TABLE 1-1. HP MODEL 8559A SPECIFICATIONS (2 OF 4)  Maximum lnput (without damage) Levels Calibrator Output  Total Power: - 10 dBm +- 0.3 dB (into S(X2)  +20 dBm (O.lW, 2.2 Vrms) with 0 dB input 35 MHz +- 400 kHz  attenuation  +30 dBm (lW, 7.1 Vrms) with 2 10 dB input  attenuation  Reference Level  DC: +-7.1V  10-dB steps and a 12-dB vernier for calibrated  AC (
                    ページ13に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 8559A  HP MODEL 8559A SPECIFICATIONS (3 OF 4)  TABLE 1-1.  EM1  Display Fidelity  Conducted and radiated interference is in com-  CRT linearity and log or linear fidelity affect  pliance with MIL-STD 461A, Methods CEO3  amplitude accuracy at levels other than Refer-  and RE02, CISPR Publication 11 (1975) and  ence Level.  Log Incremental Accuracy: Messempfaenger Postverfuegung 526/527/79  (Kennzeichnung Mit F-Nummer/Funkschutzzei-  + 0.1 dB per dB from Reference Level 
                    
                    ページ14に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 6559A  TABLE 1.1. HP MODEL8559A SPECIFICATIONS (4 OF 4)  DIMENSIONS  HP Model 182T Display:  HP Model 8559A Spectrum Analyzer:  I  201.6  TOP  17 15/16) I!  Note:  Dimensions in millimeten  and (inches).  34.9 498.5 (19 518)-  (17 13116)-4  HP Model 853A Display: HP Model 181T Display:  I  200  11  TOP^-]  [  (7 7/01  Note  Dlmenr~onr In m~lllmeterr  and Imches)  Note:  38 1 $L530 (21 1,4)-~  Dimensions in millimeters  and (~nches). +l11/2) p-491.9(193/4-q  CREAR  (11 
                    
                    ページ15に含まれる内容の要旨 
                    
                        MODEL 8559A GENERAL INFORMATION  TABLE 1-2. MODEL 8559N180-SERIES SUPPLEMENTAL CHARACTERISTICS (1 OF 3)  SUPPLEMENTAL CHARACTERISTICS  Values in this table are not specifications. They are typical characteristics  NOTE:  included for user information.  AMPLITUDE CHARACTERISTICS  FREQUENCY CHARACTERISTICS  AMPLITUDE RANGE AND ACCURACY  FREQUENCY ACCURACY  Frequency Cal Dynamic Range  Maximum power ratio of two signals simultane-  Adjusts digital FREQUENCY GHz readout.  ously present at the input 
                    
                    ページ16に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 8559A  MODEL8559A/180-SERIES  SUPPLEMENTAL CHARACTERISTICS (2 OF 3)  TABLE 1-2.  SUPPLEMENTAL CHARACTERISTICS  NOTE: Values in this table are not specifications. They are typical characteristics  included for user information.  Third Order Intermodulation Distortion lnput SWR  <2.0 SWR with 0 dB input attenuation  <1.3 SWR with r 10 dB input attenuation  Relative  Disortion  LO Emission (3.0 - 6.1 GHz)  I - 8 dBm with 0 dB input attenuation  1 -30 dBm       50 kHz     
                    
                    ページ17に含まれる内容の要旨 
                    
                        MODEL 8559A GENERAL INFORMATION  TABLE 1-2. MODEL 8559N180SERIES SUPPLEMENTAL CHARACTERISTICS (3OF 3)  SUPPLEMENTAL CHARACTERISTICS  NOTE: Values in this table are not specifications. They are typical characteristics  included for user information.  AUX C 21.4 MHz IF OUTPUT with 0 dB input attenuation). Output level is  BNC output provides 21.4 MHz IF signal (lin- approximately - 10 dBm into 50 ohms with a  early related to spectrum analyzer RF input) signal displayed at Reference Level.  from a
                    
                    ページ18に含まれる内容の要旨 
                    
                        GENERAL INFORMATION  MODEL 8559A  1-26. EQUIPMENT REQUIRED BUT NOT SUP-  response flatness is degraded by less than &0.5 dB  PLIED  from 100 MHz to 12.4 GHz; the limiter is usable  from 10 MHz to 18 GHz. Invut levels of 1 watt aver-  1-27. Display Mainframe  age or 75 watts peak can be tolerated.  1-28. An HP 853A digital Spectrum Analyzer Dis-  1.35. Low Pass Filter  play is recommended for use with the HP 8559A.  The rear panel of the HP 853A mainframe provides  the following output connection
                    
                    ページ19に含まれる内容の要旨 
                    
                        MODEL 8559A GENERAL INFORMATION  TABLE 1-3. PARTS INCLUDED IN MODIFICATION KIT 0018069503  Quantity  Description HP Part Number  1  Output Amplifier Assembly (Auxiliary Output Board) 00180-66551  1 Label  7120-3116  2 314 inch pieces of shrink tubing  0890- 0720  1  Service Note  180A/AR-10,18OC/D-2,18 1 A/AR8,  182A/C-1, or 184/B-1 (modification is  similar for all instruments listed)  1-41. SERVICE ACCESSORIES 1-44. Table 1-4 lists all of the equipment required  for testing, adjusting and trou
                    
                    ページ20に含まれる内容の要旨 
                    
                        GENERAL INFORMATION MODEL 8559A  FIGURE 16. SERVICE ACCESSORIES (1 OF 2)