ページ1に含まれる内容の要旨 
                    
                        ML-2
TECHNICAL EDUCATION
Epic™
FRONT-LOADING
 GAS AND ELECTRIC
DRYERS
 
 MODELS: MED / GD 9700S
       MED / GD 9600S
JOB AID 8178601                                                                                                                                                                                                                                                                                                                                                                      
                    
                    ページ2に含まれる内容の要旨 
                    
                        FORWARD ™ This Maytag Job Aid, “Epic Front-Loading Gas and Electric Dryers,” (Part No. 8178601), provides the In Home Service Professional with information on the installation, operation, and service of the ™ Epic Front-Loading Gas and Electric Dryers. It is to be used as a training Job Aid and Service Manual. For specific information on the model being serviced, refer to the “Use and Care Guide,” or “Tech Sheet” provided with the dryer. The Wiring Diagrams used in this Job Aid are typical and s
                    
                    ページ3に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS Page GENERAL ............................................................................................................................................ 1-1 Safety First ...................................................................................................................................... 1-1 Model & Serial Number Designations ............................................................................................. 1-2 Model & Serial Number Label And Tech Sh
                    
                    ページ4に含まれる内容の要旨 
                    
                        — NOTES — - iv -                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    
                    
                    ページ5に含まれる内容の要旨 
                    
                        GENERAL SAFETY FIRST Your safety and the safety of others is very important. We have provided many important safety messages in this Job Aid and on the appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don’t immediately follow in
                    
                    ページ6に含まれる内容の要旨 
                    
                        MODEL & SERIAL NUMBER DESIGNATIONS MODEL NUMBER MODEL NUMBER ME D 9 7 00 S Q 0 PRODUCT GROUP M = Maytag FUEL TYPE E = Electric G = Gas PRODUCT D =  Dryer SERIES 5 = LEAP 6 = Oasis 7 = 24" Front Load 8 = Mid Line Front Load 9 = Full Size Front Load PRICE POINT LEVEL (1-9) TRADE PARTNER ID 00 = Branded YEAR OF INTRODUCTION S = 2006, T = 2007 COLOR CODE B = Black Q = White ENGINEERING CHANGE SERIAL NUMBER SERIAL NUMBER M T 26 13227 DIVISION = Marion, OH YEAR OF PRODUCTION T = 2006 WEEK OF PRODUCTIO
                    
                    ページ7に含まれる内容の要旨 
                    
                        MODEL & SERIAL NUMBER LABEL AND TECH SHEET LOCATIONS The Model/Serial Number label and Tech Sheet locations are shown below. Model & Serial Number  Label Location Tech Sheet Location (Behind Lower Access Panel) 1-3                                                                                                                                                                                                                                                                                              
                    
                    ページ8に含まれる内容の要旨 
                    
                        SPECIFICATIONS  	  	
       ! ! " # # $%"& ! !   !'( !'(  )*+$, )*+$, $ -" -". /"(0  (0"(0 /"+1 %" " #2345) 3(5#66)3 #2345) 3(5#66)3 1-4                                                                                                                                                                
                    
                    ページ9に含まれる内容の要旨 
                    
                        	 	
	  		                              For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or  furnished with the product, Maytag Corporation or Maytag Limited (hereafter “Maytag”) will pay for Factory Specified Parts and repair  labor to correct defects in materials or workmanship. Service must be provided by a Maytag designated service company. This lim ited  warranty applies only when 
                    
                    ページ10に含まれる内容の要旨 
                    
                        	  
  Gather the required tools and parts before starting installation.  Read and follow the instructions provided with any tools listed 
 here.  Are you placing the dryer on a pedestal? You have the option of  Flat-blade screwdriver Vent clamps purchasing a pedestal separately for this dryer. You may select a  15.5" (39.4 cm) pedestal. This pedestal will add to the total height  #2 Phillips screwdriver Caulking gun and  of the dryer for a total he
                    
                    ページ11に含まれる内容の要旨 
                    
                        	 
   
 
         
 !   "   
  #
$ %   $  
 
 
& '  
 
    () %  *+, - "#  %  
 
  
  & .
 
  %$ $
 &    *Most installations require a minimum 5" (12.7 cm) clearance    A location that allows for proper exhaust installation. See  behind the dryer for the exhaust vent with elbow. See Venting  Venting Requirements. Requir
                    
                    ページ12に含まれる内容の要旨 
                    
                                                             	 
 	
 		
 	  
  For cabinet installation, with a door, minimum ventilation  openings in the top of the cabinet are required.                                                          *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed.                                     *Required spacing **For side or bottom venting, 0" (0 cm) spacing is allowed. 	 
 	
 		
                    
                    ページ13に含まれる内容の要旨 
                    
                        A 4-wire power supply connection must be used when the  	 
  appliance is installed in a location where grounding through  This dryer is suitable for mobile home installations. The  the neutral conductor is prohibited. Grounding through the  installation must conform to the Manufactured Home  neutral is prohibited for (1) new branch-circuit installations,  Construction and Safety Standard, Title 24 CFR, Part 3280  (2) mobile homes, (3) recreational v
                    
                    ページ14に含まれる内容の要旨 
                    
                        To supply the required 4 wire, single phase, 120/240 volt,  60 Hz., AC only electrical supply on a separate 30-amp  circuit, fused on both sides of the line. A time-delay fuse or     circuit breaker is recommended. Connect to an individual  branch circuit. For a grounded, cord-connected dryer:  This dryer must be grounded. In the event of malfunction or  This dryer is equipped with a CSA International Certified  breakdown, grounding will reduce the risk of electric shock  Pow
                    
                    ページ15に含まれる内容の要旨 
                    
                        	 
                                   #    #                                                                                                                                                                                                                       "                                          & %                 ’                                %                                       )        %                         
                    
                    ページ16に含まれる内容の要旨 
                    
                                                                             Unscrew the removable conduit connector and any          %   $             ’       #                    screws from a    / " (1.9 cm) UL listed strain relief (UL        (    marking on strain relief). Put the threaded section of the  strain relief through the hole below the terminal block  4-wire receptacle A UL listed, 4-wire connection: opening. Reaching inside the terminal block opening,  screw the removable conduit connector onto the strai
                    
                    ページ17に含まれる内容の要旨 
                    
                        		 	                    A 4-wire connection is required for mobile homes  and where local codes do not permit the use of 3-wire  connections. Direct wire cable must have 5 ft (1.52 m) of extra length so dryer  can be moved if needed.  Strip 5" (12.7 cm) of outer covering from end of cable, leaving  bare ground wire at 5" (12.7 cm). Cut 1    / " (3.8 cm) from  3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends  of wires into a hook shape.                  
                    
                    ページ18に含まれる内容の要旨 
                    
                        Connect ground wire (green or bare) of direct wire cable to Loosen or remove center silver-colored terminal block screw. external ground conductor screw. Tighten screw. Connect neutral wire (white or center wire) of power supply  cord to the center, silver-colored terminal screw of the  terminal block. Tighten screw.                                                                                                          #                               (              &                         %  
                    
                    ページ19に含まれる内容の要旨 
                    
                        When connecting to the terminal block, place the hooked end of  the wire under the screw of the terminal block (hook facing right), 	 
  squeeze hooked end together and tighten screw, as shown.                                                                                                              Remove center silver-colored terminal block screw. Remove neutral ground wire from external ground conductor  screw. Connect neutral ground wire and the neutral wire  (white o
                    
                    ページ20に含まれる内容の要旨 
                    
                        	 
                For best drying performance, rigid metal vents are   recommended. Rigid metal vent is recommended to avoid crushing and  kinking.                     Flexible metal vents are acceptable only if accessible for  cleaning.     ! Flexible metal vent must be fully extended and supported      $               %         when the dryer is in its final location.   &            %    Remove excess flexible metal vent to avoid sagging and   &            ( %     kinki