ページ1に含まれる内容の要旨 
                    
                         
 
WINE-MATE Split System 
 
Installation, Operation & Care Manual 
 
 
VINO-2500SSR 
VINO-4500SSR 
VINO-6500SSR 
 
 
 
 
 
 
 
Vinotemp International Corp. 
Vinotemp International Corp. 
 
 
www.winemate.com 
www.winemate.com 
  
READ AND SAVE THESE INSTRUCTIONS 
                                                                                                                                                                                                                                          
                    
                    ページ2に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS      Important Safety Information…..........................................2       Feature Description…………………………….……………..3      Cellar Construction.…………………………….……………..6      Installer’s Instruction…………….…..….……..……………..7      Temperature Control & Humidity Adjustment.………….14      Care Guide…………………………………………………….19                 User’ Troubleshooting…….………………………………...20      Customer Support……………………………………………22      Warranty……………………………………………………….23                              
                    
                    ページ3に含まれる内容の要旨 
                    
                        Important Safety Information              • DO NOT USE A GROUND FAULT INTERRUPTER (GFI).  • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.                                                                      - 2 -                                                                                                                                                                                                                                                                                            
                    
                    ページ4に含まれる内容の要旨 
                    
                        Feature Description    • Wine-Mate split cooling systems VINO2500-6500SSR are designed and  used to provide a cold temperature between 50~65 °F for a properly  insulated wine room at a normal environment.   • The wine room will maintain humidity of 50~70% RH even when the  environment becomes dry and humid. These temperatures and humilities  are optimized for long term storage of wine.   • SSR units consist of a condensing unit and an evaporator unit, and they  are connected by a liquid line and
                    
                    ページ5に含まれる内容の要旨 
                    
                            Fig. 1.1 WM25-45SFCR Evaporator Unit          Fig. 1.2 WM250-450SCU Condensing Unit                                                                      - 4 -                                                                                                                                                                                                                                                                                                                                                  
                    
                    ページ6に含まれる内容の要旨 
                    
                            Fig. 1.3 WM650SCU Condensing Unit                                                                                                                  - 5 -                                                                                                                                                                                                                                                                                                                                                        
                    
                    ページ7に含まれる内容の要旨 
                    
                        Cellar Construction    This is only a guide and shall be considered as minimum requirements.    All interior walls and floors shall have a vapor barrier and a minimum of R11  insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum  of R19 insulation. The vapor barrier shall be installed on the warm side of the  insulation. All joints, door frames, electrical outlets or switches and any pipes or  vents that go through the enclosure shall be sealed to prevent air and mo
                    
                    ページ8に含まれる内容の要旨 
                    
                        Installer’s Instruction    Federal law requires that WINE-MATE split cooling systems be  installed by an EPA certified refrigeration technician.    WINE-MATE split system is shipped as components and is ready for use only  after a certified refrigeration technician has properly installed, charged and tested  the system. Proper installation is critical. Vinotemp can only warrant the quality of  the components. The installation and proper operation of the system must be  warranted by the installer
                    
                    ページ9に含まれる内容の要旨 
                    
                        • Supply and return air flow from the evaporator unit shall be unobstructed  for at least 1 foot.  • There is a gravity drain line so that it can not be installed above the  evaporator unit. Otherwise a condensation pump must be used.    3. Air Sensor    • The air sensor can be located in the wine room or the return air area, but  not the supply air area.      4. Refrigeration Piping and Charging    NOTES: ALWAYS USE THE SUPERHEAT AND SUBCOOLING,  PRESSURE READINGS TO CHARGE REFRIGERANT PROPERLY
                    
                    ページ10に含まれる内容の要旨 
                    
                        5. Pressure, Superheat and Subcooling Readings    NOTES: THE VALVES MUST BE IN THE MIDDLE POSITIONS TO READ  PROPERLY.    Complaint Possible Causes  a. High suction pressure and low head pressure a. Compressor may be bad  b. High suction pressure and low head pressure b. Expansion valve opened, too         Low superheat and low subcooling much oil  c. High suction pressure and high head pressure c. Overcharge         Low superheat and high subcooling   d. High to normal suction pressure and high
                    
                    ページ11に含まれる内容の要旨 
                    
                        Back Position: Process and manometer port closed for normal operation  Front Position: Main connection to liquid or suction line closed  Middle Position: All ports open for vacuum, charge and measurement    7. Electrical Wiring      Fig. 2.2 VINO2500-4500SSR Electrical Wiring Diagram (VTSTAT)                                                                        - 10 -                                                                                                                                 
                    
                    ページ12に含まれる内容の要旨 
                    
                          Fig. 2.3 VINO2500-4500SSR Wiring Diagram (DIGITAL CONTROLLER)      Fig. 2.4 VINO6500SSR Electrical Wiring Diagram (VTSTAT)                                                                        - 11 -                                                                                                                                                                                                                                                                                                          
                    
                    ページ13に含まれる内容の要旨 
                    
                          Fig. 2.5 VINO6500SSR Electrical Wiring Diagram (DIGITAL CONTROLLER)    8. Use of the adjustable low pressure control (if applicable)  Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig  It may need to adjust the setting in the field to get the right cycle time.    Fig. 2.6 Adjustable Pressure Control                                                                      - 12 -                                                                                                                 
                    
                    ページ14に含まれる内容の要旨 
                    
                        9. Condensing Unit Troubleshooting    Unit not running  a. Incorrect power supply a. Check for proper voltage  b. Incorrect or loose wirings b. Check all wirings and  connections  c. Failed components c. Check start relay, start capacitor, overload   protector, compressor.  d. Liquid refrigerant in the compressor d. Call service for OEM information   e. Check for system restriction or low  e. Low pressure switch shutting down the system refrigerant                                                
                    
                    ページ15に含まれる内容の要旨 
                    
                        Temperature Control & Humidity Adjustment    1. Temperature Setting    • Set the temperature at 55 °F for the optimum aging of wine  • On initial start-up, the time required to reach the desired temperature  will vary, depending on the quantity of bottles, temperature setting  and surrounding temperature.  • Allow 24 hours to stabilize the temperature for each new temperature  setting operation    2. Use of the VTSTAT controller    NOTE: Use the dial number for “Medium Temp”           Fig. 3.1 V
                    
                    ページ16に含まれる内容の要旨 
                    
                        Dip-switch description (See detail in VSTAT instruction )   1, 2 differential: added to the Set Point, establishes the temperature threshold,  measured by the regulation probe, beyond which the compressor is activated;  3 compressor safety function: OFF - function disabled; ON - function enabled;  4 temperature display: OFF - displayed in °C; ON - displayed in °F;  5,...,8 duration of defrost/defrost termination temperature: if the defrost sensor is  utilized, these dip-switches select the defro
                    
                    ページ17に含まれる内容の要旨 
                    
                        If the function is enabled, the compressor is not energized for three minutes after  controller power up.  The function is also active in hot-gas defrost mode.    5) LED & Display Messages    1. LED off 1. Compressor and defrost deactivated  2. LED on 2. Compressor energized  3. LED blinking 0.5s on/0.5s off 3. Defrost activated  4. LED blinking 0.5s on/1.5s off 4. Sensor fault  5. Display A1 5. Regulation probe fault  6. Display A2 6. Defrost probe fault    3. Use of the Digital Controller     
                    
                    ページ18に含まれる内容の要旨 
                    
                            2) Alarm Signals  2.1 Code Description        2.2 Alarm Recovery   Probe alarms P1”, start a few seconds after the fault in the related probe; they  automatically stop a few seconds after the probe restarts normal operation.  Check connections before replacing the probe. Temperature alarms “HA”, “LA”  automatically stops as soon as the temperature returns to normal value. Alarm  “CA” (with i1F=PAL) recovers only by switching off and on the instrument.     3) Temperature Set-Point  3.1 How to
                    
                    ページ19に含まれる内容の要旨 
                    
                        2. The value of the set point will be displayed and the “°C” or “°F” LED starts  blinking;   3. To change the Set value, push the o or n arrows within 10s.   4. To memorize the new set point value, push the SET key again or wait 10s.    4) Humidity Adjustment  The parameter Fon is used to adjust the humidity in the wine cabinet. The higher  value of Fon, the higher relative humidity will be.  1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.  2. Release the keys, then
                    
                    ページ20に含まれる内容の要旨 
                    
                        Care Guide         In general, always unplug system or disconnect power while doing care.    1. Coil Cleaning    • Clean the condenser coil regularly. Coil may need to be cleaned at least  every 6 months.  • Unplug the system or disconnect power.  • Use a vacuum cleaner with an extended attachment to clean the coil when it  is dusty or dirty.  • Plug cooling system or reconnect power.    2. Moisture Removing    • Remove the extra condensate if it is accumulated in the wine cellar at high  ambien