WINE-MATE Split System 
 
Installation, Operation & Care Manual 
 
 
 
VINO2500SSH, 4500SSH 
VINO6500SSH, 8500SSH 
 
 
 
 
 
 
 
 
 
 
 
V Vi in no ot te em mp p  I In nt te er rn na at ti io on na al l  C Co or rp p..  
  
w ww ww w..w wiin ne em ma at te e..c co om m  
  
READ AND SAVE THESE INSTRUCTIONS 
 
                                                                                                                                                                                         
                    
                    ページ2に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS      Important Safety Information…..........................................2       Feature Description…………………………….……………..3      Cellar Construction.…………………………….……………..6      Installer’s Instruction…………….…..….……..……………..7      Temperature Control & Humidity Adjustment.………….15      Care Guide…………………………………………………….20                 User’ Troubleshooting…….………………………………...21      Customer Support……………………………………………23      Warranty……………………………………………………….24                              
                    
                    ページ3に含まれる内容の要旨 
                    
                        Important Safety Information              • DO NOT USE A GROUND FAULT INTERRUPTER (GFI).  • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.                                                                      - 2 -                                                                                                                                                                                                                                                                                            
                    
                    ページ4に含まれる内容の要旨 
                    
                        Feature Description    • Wine-Mate split cooling systems VINO2500-8500SSH are designed and  used to provide a cold temperature between 50~65 °F for a properly  insulated wine room at a normal environment.   • The wine room will maintain humidity of 50~70% RH even when the  environment becomes dry and humid. These temperatures and humilities  are optimized for long term storage of wine.   • SSH units consist of a condensing unit and an evaporator unit, and they  are connected by a liquid line and
                    
                    ページ5に含まれる内容の要旨 
                    
                            Fig. 1.1 WM25-85SFCH Evaporator Unit        Fig. 1.2 WM250-450SCU Condensing Unit                                                                      - 4 -                                                                                                                                                                                                                                                                                                                                                    
                    
                    ページ6に含まれる内容の要旨 
                    
                            Fig. 1.3 WM650-850SCU Condensing Unit                                                                                                                  - 5 -                                                                                                                                                                                                                                                                                                                                                    
                    
                    ページ7に含まれる内容の要旨 
                    
                        Cellar Construction    This is only a guide and shall be considered as minimum requirements.    All interior walls and floors shall have a vapor barrier and a minimum of R11  insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum  of R19 insulation. The vapor barrier shall be installed on the warm side of the  insulation. All joints, door frames, electrical outlets or switches and any pipes or  vents that go through the enclosure shall be sealed to prevent air and mo
                    
                    ページ8に含まれる内容の要旨 
                    
                        Installer’s Instruction    Federal law requires that WINE-MATE split cooling systems be  installed by an EPA certified refrigeration technician.    WINE-MATE split system is shipped as components and is ready for use only  after a certified refrigeration technician has properly installed, charged and tested  the system. Proper installation is critical. Vinotemp can only warrant the quality of  the components. The installation and proper operation of the system must be  warranted by the installer
                    
                    ページ9に含まれる内容の要旨 
                    
                        1. Condensing Unit    • Place the condensing units WM250-850SCU in a properly ventilated  location. If it is not, heat exhausted by the condensing unit will build up  and the cooling system will not operate properly.   • Leave minimum 5 feet clearance for the exhaust side and leave minimum  1 foot clearance for the fresh air intake side.  • Condensing unit shall be elevated to avoid possible flooding and shaded  from direct sun. It shall not be exposed to temperatures higher than 110  °F or lowe
                    
                    ページ10に含まれる内容の要旨 
                    
                        • The evaporator’s constant pressure expansion valve is set around 38- 40°F at factory. This pressure setting gives a dew point to maintain the  humidity for storing wine.    • The superheat at the evaporator unit shall be around 9-18°F under low  and high load at 75°F ambient temperature.   • Low side pressure: 33 psig  • High side pressure: 130 -150 psig at 75 -90 °F ambient temperatures    The line sizes and refrigerant charges are listed as follows.    REFRIGERATION LIQUID SUCTION DRAIN  MOD
                    
                    ページ11に含まれる内容の要旨 
                    
                              High superheat and high subcooling restricted  n. Low  suction pressure and high head pressure n. Liquid line restricted before         High superheat and high subcooling receiver  o. low to normal suction pressure and high head pressure o. Condenser restricted         High to normal superheat and high subcooling       6. Valve Operation          SPINDLE BACK POSITION    SPINDLE FRONT POSITION    SPINDLE MIDDLE POSITION    Fig. 2.2 Valve Operation    Back Position: Process and manometer po
                    
                    ページ12に含まれる内容の要旨 
                    
                        7. Electrical Wiring      Fig. 2.3 VINO2500 & 4500SSH Electrical Wiring Diagram (VTSTAT)      Fig. 2.4 VINO2500 & 4500SSH Wiring Diagram (DIGITAL CONTROLLER)                                                                      - 11 -                                                                                                                                                                                                                                                                           
                    
                    ページ13に含まれる内容の要旨 
                    
                          Fig. 2.5 VINO6500SSH Electrical Wiring Diagram (VTSTAT)      Fig. 2.6 VINO6500SSH Electrical Wiring Diagram (DIGITAL CONTROLLER)                                                                      - 12 -                                                                                                                                                                                                                                                                                                      
                    
                    ページ14に含まれる内容の要旨 
                    
                          Fig. 2.7 VINO8500SSH Electrical Wiring Diagram (VTSTAT, UJ6220Z)      Fig. 2.8 VINO8500SSH Wiring Diagram (DIGITAL CONTROLLER, UJ6220Z)                                                                        - 13 -                                                                                                                                                                                                                                                                                             
                    
                    ページ15に含まれる内容の要旨 
                    
                        8. Use of the adjustable low pressure control (if applicable)    Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig;   It may need to adjust the setting in the field to get the right cycle time.    Fig. 2.9 Adjustable Low Pressure Control    9. Condensing Unit Troubleshooting    Unit not running  a. Incorrect power supply a. Check for proper voltage  b. Incorrect or loose wirings b. Check all wirings and  connections  c. Failed components c. Check start relay, start capacitor, overload  
                    
                    ページ16に含まれる内容の要旨 
                    
                        Temperature Control & Humidity Adjustment      1. Temperature Setting    • Set the temperature at 55 °F for the optimum aging of wine  • On initial start-up, the time required to reach the desired temperature  will vary, depending on the quantity of bottles, temperature setting  and surrounding temperature.  • Allow 24 hours to stabilize the temperature for each new temperature  setting operation    2. Use of the VTSTAT controller    NOTE: Use the dial number for “Medium Temp”           Fig. 3.1
                    
                    ページ17に含まれる内容の要旨 
                    
                        Dip-switch description (See detail in VSTAT instruction )   1, 2 differential: added to the Set Point, establishes the temperature threshold,  measured by the regulation probe, beyond which the compressor is activated;  3 compressor safety function: OFF - function disabled; ON - function enabled;  4 temperature display: OFF - displayed in °C; ON - displayed in °F;  5,...,8 duration of defrost/defrost termination temperature: if the defrost sensor is  utilized, these dip-switches select the defro
                    
                    ページ18に含まれる内容の要旨 
                    
                        If the function is enabled, the compressor is not energized for three minutes after  controller power up.  The function is also active in hot-gas defrost mode.    5) LED & Display Messages    1. LED off 1. Compressor and defrost deactivated  2. LED on 2. Compressor energized  3. LED blinking 0.5s on/0.5s off 3. Defrost activated  4. LED blinking 0.5s on/1.5s off 4. Sensor fault  5. Display A1 5. Regulation probe fault  6. Display A2 6. Defrost probe fault    3. Use of the Digital Controller    F
                    
                    ページ19に含まれる内容の要旨 
                    
                            2) Alarm Signals  2.1 Code Description      2.2 Alarm Recovery   Probe alarms P1”, start a few seconds after the fault in the related probe; they  automatically stop a few seconds after the probe restarts normal operation.  Check connections before replacing the probe. Temperature alarms “HA”, “LA”  automatically stops as soon as the temperature returns to normal value. Alarm  “CA” (with i1F=PAL) recovers only by switching off and on the instrument.     3) Temperature Set-Point  3.1 How to s
                    
                    ページ20に含まれる内容の要旨 
                    
                        2. The value of the set point will be displayed and the “°C” or “°F” LED starts  blinking;   3. To change the Set value, push the o or n arrows within 10s.   4. To memorize the new set point value, push the SET key again or wait 10s.    4) Humidity Adjustment  The parameter Fon is used to adjust the humidity in the wine cabinet. The higher  value of Fon, the higher relative humidity will be.  1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.  2. Release the keys, then