ページ1に含まれる内容の要旨 
                    
                         
 
 
WINE-MATE Ducted System 
 
Installation, Operation & Care Manual 
 
 
VINO4500DS 
VINO6500DS 
VINO8500DS 
 
 
 
 
 
 
 
 
 
 
 
V Vi in no ot te em mp p  I In nt te er rn na at ti io on na al l  C Co or rp p..  
  
w ww ww w..w wiin ne em ma at te e..c co om m                                                                                                                                                                                                                                          
                    
                    ページ2に含まれる内容の要旨 
                    
                        READ AND SAVE THESE INSTRUCTIONS      TABLE OF CONTENTS      Important Safety Information…..........................................2       Feature Description…………………………….……………..3      Cellar Construction.…………………………….……………..5      Installer’s Instruction…………….…..….……..……………..6      Temperature Control & Humidity Adjustment....…………8      Service Guide………………….……………………………...13      Care Guide…………………………………………………….19                 User’ Troubleshooting…….………………………………...20      Customer Support……………
                    
                    ページ3に含まれる内容の要旨 
                    
                        Important Safety Information              • DO NOT USE A GROUND FAULT INTERRUPTER (GFI).  • A DEDICATED 20 AMP CIRCUIT IS HIGHLY RECOMMENDED.                                                                      - 2 -                                                                                                                                                                                                                                                                                            
                    
                    ページ4に含まれる内容の要旨 
                    
                        Feature Description      • WINE-MATE ducted system VINO4500-8500DS are designed and used to  provide a cold temperature between 50~65 °F for a properly insulated  wine room at a normal environment.   • The wine room will maintain humidity of 50~70% RH even when the  environment becomes dry and humid. These temperatures and humilities  are optimized for long term storage of wine.   • The DS ducted systems are designed for both outdoor and indoor  installation.  • Back-curved impeller fans are goo
                    
                    ページ5に含まれる内容の要旨 
                    
                        The dimensions and capacities are specified as follows:      Btu/h BOTTLE  DIMENSION  CAPACITY  MODEL REFRIGERANT ELECTRICAL WEIGHT(lb)   (55/90°F)  L”xH”xW”  (55/75°F)  CFM  VINO- 1000  4500  45X23 X34 4500/380 R134a 115V-60HZ-8A  140  4500DS cu ft bottles  VINO- 1500  6500  45X23 X34 6500/490 R134a 115V-60HZ-14A 170  6500DS cu ft bottles  VINO- 2000  8500  45X25 X34 8500/750 R134a 115V-60HZ-17A  220  8500DS cu ft bottles          Fig. 1.2 VINO4500- 8500DS DIMENSIONS                            
                    
                    ページ6に含まれる内容の要旨 
                    
                        Cellar Construction    This is only a guide and shall be considered as minimum requirements.    All interior walls and floors shall have a vapor barrier and a minimum of R11  insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum  of R19 insulation. The vapor barrier shall be installed on the warm side of the  insulation. All joints, door frames, electrical outlets or switches and any pipes or  vents that go through the enclosure shall be sealed to prevent air and mo
                    
                    ページ7に含まれる内容の要旨 
                    
                        Installer’s Instruction    Federal law requires that WINE-MATE ducted cooling systems  be installed by an EPA certified refrigeration technician.    WINE-MATE ducted system is shipped ready for use only after a certified  refrigeration technician has properly installed the system. Proper installation is  critical. Vinotemp can only warrant the quality of the components. The installation  and proper operation of the system must be warranted by the installer.  Installation of the system must be do
                    
                    ページ8に含まれる内容の要旨 
                    
                        1. Location  • Place the unit in a properly ventilated location. If it is not, heat exhausted  by the condensing unit will build up and the cooling system will not operate  properly.   • Leave minimum 5 feet clearance for hot air exhaust and leave minimum 1  foot clearance for the fresh air intake.  • Air flow from the cold air supply shall be unobstructed for at least 1 foot.  • Cooling unit shall be elevated to avoid possible flooding and shaded from  direct sun. It shall not be exposed to tem
                    
                    ページ9に含まれる内容の要旨 
                    
                        Temperature Control & Humidity Adjustment      1. Temperature Setting    • Set the temperature at 55 °F for the optimum aging of wine  • On initial start-up, the time required to reach the desired temperature  will vary, depending on the quantity of bottles, temperature setting  and surrounding temperature.  • Allow 24 hours to stabilize the temperature for each new temperature  setting operation    2. Use of the VTSTAT electronic temperature controller            Fig. 3.1 VTSTAT      Fig. 3.2 D
                    
                    ページ10に含まれる内容の要旨 
                    
                        Dip-switch description (See detail in VSTAT instruction)   1, 2 differential: added to the Set Point, establishes the temperature threshold,  measured by the regulation probe, beyond which the compressor is activated;  3 compressor safety function: OFF - function disabled; ON - function enabled;  4 temperature display: OFF - displayed in °C; ON - displayed in °F;  5,...,8 duration of defrost/defrost termination temperature: if the defrost sensor is  utilized, these dip-switches select the defros
                    
                    ページ11に含まれる内容の要旨 
                    
                        If the function is enabled, the compressor is not energized for three minutes after  controller power up.  The function is also active in hot-gas defrost mode.    5) LED & Display Messages    1. LED off 1. Compressor and defrost deactivated  2. LED on 2. Compressor energized  3. LED blinking 0.5s on/0.5s off 3. Defrost activated  4. LED blinking 0.5s on/1.5s off 4. Sensor fault  5. Display A1 5. Regulation probe fault  6. Display A2 6. Defrost probe fault    3. Use of the Digital Controller     
                    
                    ページ12に含まれる内容の要旨 
                    
                            2) Alarm Signals  2.1 Code Description        2.2 Alarm Recovery   Probe alarms P1”, start a few seconds after the fault in the related probe; they  automatically stop a few seconds after the probe restarts normal operation.  Check connections before replacing the probe. Temperature alarms “HA”, “LA”  automatically stops as soon as the temperature returns to normal value. Alarm  “CA” (with i1F=PAL) recovers only by switching off and on the instrument.     3) Temperature Set-Point  3.1 How to
                    
                    ページ13に含まれる内容の要旨 
                    
                        2. The value of the set point will be displayed and the “°C” or “°F” LED starts  blinking;   3. To change the Set value, push the o or n arrows within 10s.   4. To memorize the new set point value, push the SET key again or wait 10s.    4) Humidity Adjustment  The parameter Fon is used to adjust the humidity in the wine cabinet. The higher  value of Fon, the higher relative humidity will be.  1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.  2. Release the keys, then
                    
                    ページ14に含まれる内容の要旨 
                    
                        Service Guide    1. Refrigeration Piping and Charge     • The subcooling at the condensing unit shall be around 10°F. The charge  may be complete when there are no more bubbles forming in the sight  glass.  • The evaporator’s constant pressure expansion valve is set around 38- 40°F at factory. This pressure setting gives a dew point to maintain the  humidity for storing wine.  • The superheat at the evaporator unit shall be around 9-18°F under low  and high load at 75°F ambient temperature.   • 
                    
                    ページ15に含まれる内容の要旨 
                    
                        k. Low suction pressure and low to normal head pressure k. Evaporator restricted        High superheat and normal to high subcooling   l. Low suction pressure and normal head pressure l. Expansion valve restricted         High superheat and normal subcooling   m. Low suction pressure and high head pressure m. Both evaporator and condenser        High superheat and high subcooling restricted  n. Low  suction pressure and high head pressure n. Liquid line restricted before         High superheat a
                    
                    ページ16に含まれる内容の要旨 
                    
                        4. Electrical Wiring    Fig. 4.2 VINO4500DS Electrical Wiring Diagram (VTSTAT)    Fig. 4.3 VINO4500DS Electrical Wiring Diagram (DIGITAL CONTROLLER)                                                                      - 15 -                                                                                                                                                                                                                                                                                    
                    
                    ページ17に含まれる内容の要旨 
                    
                          Fig. 4.4 VINO6500DS Electrical Wiring Diagram (VTSTAT)    Fig. 4.5 VINO6500DS Electrical Wiring Diagram (DIGITAL CONTROLLER)                                                                      - 16 -                                                                                                                                                                                                                                                                                                          
                    
                    ページ18に含まれる内容の要旨 
                    
                          Fig. 4.6 VINO8500DS Electrical Wiring Diagram (VTSTAT, UJ6220Z)    Fig. 4.7 VINO8500DS Wiring Diagram (DIGITAL CONTROLLER, UJ6220Z)                                                                      - 17 -                                                                                                                                                                                                                                                                                                   
                    
                    ページ19に含まれる内容の要旨 
                    
                        5. Use of the adjustable low pressure control (if applicable)    Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig      Fig. 4.8 Adjustable Low Pressure Control    6. Condensing Unit Troubleshooting    Unit not running  a. Incorrect power supply a. Check for proper voltage  b. Incorrect or loose wirings b. Check all wirings and  connections  c. Failed components c. Check start relay, start capacitor, overload   protector, compressor.  d. Liquid refrigerant in the compressor d. Call serv
                    
                    ページ20に含まれる内容の要旨 
                    
                        Care Guide         In general, always unplug system or disconnect power while doing care.    1. Coil Cleaning    • Clean the condenser coil regularly. Coil may need to be cleaned at least  every 6 months.  • Unplug the system or disconnect power.  • Use a vacuum cleaner with an extended attachment to clean the coil when it  is dusty or dirty.  • Plug cooling system or reconnect power.    2. Moisture Removing    • Remove the extra condensate if it is accumulated in the wine cellar at high  ambien