ページ1に含まれる内容の要旨 
                    
                         
 
WINE-MATE Split System 
Installation, Operation & Care Manual 
 
VINO-1500SSW 
VINO-2500SSW 
 
 
V Vi in no ot te em mp p  I In nt te er rn na at ti io on na al l  C Co or rp p..  
  
w ww ww w..w wiin ne em ma at te e..c co om m  
 
 
READ AND SAVE THESE INSTRUCTIONS 
                                                                                                                                                                                                                                  
                    
                    ページ2に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS      Important Safety Information….........................................2     Feature Description…………………………….……………..3    Cellar Construction…………………………….……………..5    Installer’s Instruction…………….…..….……..……………..6    Temperature Control & Humidity Adjustment….……….11    Care Guide…………………………………………………….14               User’ Troubleshooting…….………………………………...15    Customer Support……………………………………………17    Warranty……………………………………………………….18                                                
                    
                    ページ3に含まれる内容の要旨 
                    
                        Important Safety Information              • DO NOT USE A GROUND FAULT INTERRUPTER (GFI).  • A DEDICATED 15 AMP CIRCUIT IS HIGHLY RECOMMENDED.                                                                      - 2 -                                                                                                                                                                                                                                                                                            
                    
                    ページ4に含まれる内容の要旨 
                    
                        Feature Description    • Wine-Mate split cooling systems VINO1500SSW and 2500SSW are  designed and used to provide a cold temperature between 50~65 °F for a  properly insulated wine room at a normal environment.   • The wine room will maintain humidity of 50~70% RH even when the  environment becomes dry and humid. These temperatures and humilities  are optimized for long term storage of wine.   • SSW units consist of a condensing unit and an evaporator unit, and they  are connected by a liquid l
                    
                    ページ5に含まれる内容の要旨 
                    
                            Fig. 1.1 WM15-25SFCW Evaporator Unit        Fig. 1.2 WM150-250SCU Condensing Unit                                                                      - 4 -                                                                                                                                                                                                                                                                                                                                                    
                    
                    ページ6に含まれる内容の要旨 
                    
                        Cellar Construction    This is only a guide and shall be considered as minimum requirements.    All interior walls and floors shall have a vapor barrier and a minimum of R11  insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum  of R19 insulation. The vapor barrier shall be installed on the warm side of the  insulation. All joints, door frames, electrical outlets or switches and any pipes or  vents that go through the enclosure shall be sealed to prevent air and mo
                    
                    ページ7に含まれる内容の要旨 
                    
                        Installer’s Instruction    Federal law requires that WINE-MATE split cooling systems be  installed by an EPA certified refrigeration technician.    WINE-MATE split system is shipped as components and is ready for use only  after a certified refrigeration technician has properly installed, charged and tested  the system. Proper installation is critical. Vinotemp can only warrant the quality of  the components. The installation and proper operation of the system must be  warranted by the installer
                    
                    ページ8に含まれる内容の要旨 
                    
                        • Supply and return air flow from the evaporator unit shall be unobstructed  for at least 1 foot.  • There is a gravity drain line so that it can not be installed above the  evaporator unit. Otherwise a condensation pump must be used.    3. Air Sensor    • The air sensor can be located in the wine room or the return air area, but  not the supply air area.      4. Refrigeration Piping and Charging    NOTES: ALWAYS USE THE SUPERHEAT AND SUBCOOLING,  PRESSURE READINGS TO CHARGE REFRIGERANT PROPERLY
                    
                    ページ9に含まれる内容の要旨 
                    
                        Complaint Possible Causes  a. High suction pressure and low head pressure a. Compressor may be bad  b. High suction pressure and low head pressure b. Expansion valve opened, too         Low superheat and low subcooling much oil  c. High suction pressure and high head pressure c. Overcharge         Low superheat and high subcooling   d. High to normal suction pressure and high head pressure d. Non-condensable gas         Low subcooling   e. High suction pressure and high head pressure e. Air rest
                    
                    ページ10に含まれる内容の要旨 
                    
                        7. Electrical Wiring        Fig. 2.2 VINO1500-2500SSW Wiring Diagram (DIGITAL CONTROLLER)                                                                                                            - 9 -                                                                                                                                                                                                                                                                                                          
                    
                    ページ11に含まれる内容の要旨 
                    
                        8. Use of the adjustable low pressure control (if applicable)    Cut out = 5 psig; Cut in = 25 psig; Differential = 20 psig  It may need to adjust the setting in the field to get the right cycle time.        Fig. 2.3 Adjustable Pressure Control    9. Condensing Unit Troubleshooting    Unit not running  a. Incorrect power supply a. Check for proper voltage  b. Incorrect or loose wirings b. Check all wirings and  connections  c. Failed components c. Check start relay, start capacitor, overload   p
                    
                    ページ12に含まれる内容の要旨 
                    
                        Temperature Control & Humidity Adjustment    1. Temperature Setting    • Set the temperature at 55 °F for the optimum aging of wine  • On initial start-up, the time required to reach the desired temperature  will vary, depending on the quantity of bottles, temperature setting  and surrounding temperature.  • Allow 24 hours to stabilize the temperature for each new temperature  setting operation    2. Use of the Digital Controller        Fig. 3.1 Digital Controller    1) Display  During normal op
                    
                    ページ13に含まれる内容の要旨 
                    
                            2) Alarm Signals  2.1 Code Description      2.2 Alarm Recovery   Probe alarms P1”, start a few seconds after the fault in the related probe; they  automatically stop a few seconds after the probe restarts normal operation.  Check connections before replacing the probe. Temperature alarms “HA”, “LA”  automatically stops as soon as the temperature returns to normal value. Alarm  “CA” (with i1F=PAL) recovers only by switching off and on the instrument.     3) Temperature Set-Point  3.1 How to s
                    
                    ページ14に含まれる内容の要旨 
                    
                        2. The value of the set point will be displayed and the “°C” or “°F” LED starts  blinking;   3. To change the Set value, push the o or n arrows within 10s.   4. To memorize the new set point value, push the SET key again or wait 10s.    4) Humidity Adjustment  The parameter Fon is used to adjust the humidity in the wine cabinet. The higher  value of Fon, the higher relative humidity will be.  1. Press the Set + keys for 3 sec until the “°C” or “°F” LED starts blinking.  2. Release the keys, then
                    
                    ページ15に含まれる内容の要旨 
                    
                        Care Guide         In general, always unplug system or disconnect power while doing care.    1. Coil Cleaning    • Clean the condenser coil regularly. Coil may need to be cleaned at least  every 6 months.  • Unplug the system or disconnect power.  • Use a vacuum cleaner with an extended attachment to clean the coil when it  is dusty or dirty.  • Plug cooling system or reconnect power.    2. Moisture Removing    • Remove the extra condensate if it is accumulated in the wine cellar at high  ambien
                    
                    ページ16に含まれる内容の要旨 
                    
                        User’s Troubleshooting    This Troubleshooting Chart is not prepared to replace the training required for a  professional refrigeration service person, not is it comprehensive    Troubleshooting Chart    Complaint Possible Causes Response  a. No power a. Check power at receptacle & fuses  1.Unit not  b. Power cord unplugged b. Check for power cord plug  running  c. Setting higher than ambient c. Lower temperature setting  temperature   d. Defrost light blinking d. Unit is under defrost mode  e. 
                    
                    ページ17に含まれる内容の要旨 
                    
                         intake side   e. Malfunctioning fans e. Check for both evaporator and   condenser fans   f. Improper evaporator or f. Check for air restrictions  condenser airflow   g. Dirty Condenser g. Clean condenser  h. Iced evaporator h. Defrost and reset temperature  i. Refrigeration system restriction i. Call service for checking  restrictions j. Sealed system problem j. Call service for checking loss of   refrigerant or restrictions  k. Undercharge or overcharge k. Call service to add or remove   refri
                    
                    ページ18に含まれる内容の要旨 
                    
                        Customer Support      If you still have problems, please contact us at:      Vinotemp International   17631 South Susana Road   Rancho Dominguez, CA 90221   Tel:  (310) 886-3332   Fax: (310) 886-3310   Email: info@vinotemp.com                                                                                                                        - 17 -                                                                                                                                                    
                    
                    ページ19に含まれる内容の要旨 
                    
                        Warranty       Thank you for choosing a Vinotemp cooling unit.    Please enter the complete model and serial numbers in the space provided:    Model_________________________________________________________  Serial No.______________________________________________________    Attach your purchase receipt to this owner’s manual.      1.  Limited Warranty              VINOTEMP warrants its products, parts only, to be free from defects due to  workmanship or materials under normal use and service for
                    
                    ページ20に含まれる内容の要旨 
                    
                        VINOTEMP will, at its discretion, repair or replace the unit and return it free of  charge to the original retail customer. If the unit is found to be in good working  order, or beyond the initial twelve month period, it will be returned freight collect.          2. Limitation of Implied Warranty    VINOTEMP’S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED  TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT.    VINOTEMP SHALL NOT BE LIABLE FOR:  DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS