                    ページ2に含まれる内容の要旨 
                    
                        Important Safety Information    • DO NOT PLUG IN UNTIL 24 HOURS AFTER DELIVERY.  • DO NOT USE A GROUND FAULT INTERRUPTER (GFI).  • A DEDICATED 15 AMPCIRCUIT IS HIGHLY RECOMMENDED.                                                                          - 1 -                                                                                                                                                                                                                                                  
                    
                    ページ3に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS      Feature Description…………………………….……………..3    Installation Instruction………………………………………..5    Temperature Control & Humidity Adjustment……..…….8    Care Guide……………………………………………………12               Troubleshooting……………………………………………..14    Wiring Diagram……………………………………….………17     Customer Support……………………………………………18    Warranty……………………………………………………….19                                                                                                                    - 2 -                
                    
                    ページ4に含まれる内容の要旨 
                    
                        Feature Description      • WM1500HTD, HTD-TE and WM2500HTD, HTD-TE cooling units are  designed and used to provide a subtle temperature between 50~65 °F for  suitable space at a normal environment.  • The refrigerated space will maintain humidity of 50~70% RH even when  the environment becomes dry and humid.  • These temperatures and humilities are optimized for long term storage of  wine.  • Humidity and temperature digital control using patent pending technology  • Optimized air flow for most 
                    
                    ページ5に含まれる内容の要旨 
                    
                            Fig. 1.2 DIMENSIONS (in)      The dimensions and capacity are specified as follows:    Cooling  Bottle  Capacity,  Model Exhaust Electrical Weight  Capacity  CFM  55°F/75°F  55°F/75°F   1500 Btu/h, 800  1500htd Rear Exhaust 150 cu ft 115V/60Hz 4A 55 lb  120 CFM bottles 1500 Btu/h, 800  1500htd-te Top Exhaust 150 cu ft 115V/60Hz 4A 55 lb  120 CFM bottles 2500 Btu/h, 1200  2500htd Rear Exhaust 250 cu ft 115V/60Hz 5A 60 lb  180 CFM bottles 2500 Btu/h, 1200  2500htd-te Top Exhaust 250 cu ft 115V
                    
                    ページ6に含まれる内容の要旨 
                    
                        Installation Instruction      1. Cabinet Location  • Place the wine cabinet in a properly ventilated location. Otherwise, heat  exhausted by the cooling unit will build up and it will not operate properly.   • The exhaust area must not be closed space and must be ventilated. The  ambient temperatures shall not be higher than 90 °F or lower than 50 °F.    1) Rear Exhaust Location  • Leave min 6 “clearance from the rear to the wall.  • Leave min 12” clearance from the top to the ceiling.  • Leave 
                    
                    ページ7に含まれる内容の要旨 
                    
                          Fig. 2.2 COOLING UNIT MOUNTING            Fig. 2.3 MOUNTING CUTOUT & GASKET LIPS  (LOCATED AT THE CABINET)                                                                      - 6 -                                                                                                                                                                                                                                                                                                                             
                    
                    ページ8に含まれる内容の要旨 
                    
                          Fig. 2.3 TOP EXHAUST GASKET  (LOCATED ON THE COOLING UNIT)  • Cut a rectangular inside opening at the rear of the cabinet with the 1/4”  clearance inwards to the width and height of the cooling unit. By not going  through, leave 1/2” lip inside at the wall to place the gaskets (see Fig. 2.2).  • If top exhaust, cut another rectangular opening at the top of the cabinet to  the length and width of the top exhaust (see Fig.2.2).  • Make 2 holes at the ceiling to install the 1/4 inside diameter wo
                    
                    ページ9に含まれる内容の要旨 
                    
                        Temperature Control & Humidity Adjustment    1. Temperature Setting    • Set the temperature at 55 °F for the optimum aging of wine  • On initial start-up, the time required to reach the desired temperature  will vary, depending on the quantity of bottles, temperature setting  and surrounding temperature.  • Allow 24 hours to stabilize the temperature for each new temperature  setting operation    2. Use of the controller        Fig. 3.1 DIGITAL CONTROLLER    1) Display    During normal operatin
                    
                    ページ10に含まれる内容の要旨 
                    
                            2) Alarm Signals    2.1 Code Description      2.2 Alarm Recovery     Probe alarms P1”, start a few seconds after the fault in the related probe; they  automatically stop a few seconds after the probe restarts normal operation.  Check connections before replacing the probe. Temperature alarms “HA”, “LA”  automatically stops as soon as the temperature returns to normal value. Alarm  “CA” (with i1F=PAL) recovers only by switching off and on the instrument.     3) Temperature Set-Point    3.1 Ho
                    
                    ページ11に含まれる内容の要旨 
                    
                        3.2 How to change the set-point   1. Push the SET key for more than 3 seconds to change the Set point value;   2. The value of the set point will be displayed and the “°C” or “°F” LED starts  blinking;   3. To change the Set value, push the keys  or  arrows within 10s.   4. To memorize the new set point value, push the SET key again or wait 10s.    4) Humidity Adjustment  The parameter Fon is used to adjust the humidity in the wine cabinet. The higher  value of Fon, the higher relative humidity 
                    
                    ページ12に含まれる内容の要旨 
                    
                        7) Manual Defrost  Push the DEF key for more than 2 seconds and a manual defrost will start.                                                                                                                                                              - 11 -                                                                                                                                                                                                                                                    
                    
                    ページ13に含まれる内容の要旨 
                    
                        Care Guide     I. Component Identification            Fig. 4.1 Exploded View                                                                      - 12 -                                                                                                                                                                                                                                                                                                                                                            
                    
                    ページ14に含まれる内容の要旨 
                    
                        II. Condenser Coil Cleaning    • The condenser coil is on the ambient air intake side of the cooling unit.  • Clean the condenser coil regularly. Coil may need to be cleaned at  least every 6 months.  • Unplug the unit or disconnect power.  • Use a condenser brush or a vacuum cleaner with an extended  attachment to clean the coil when it is dusty or dirty.  • Plug the unit or reconnect power.    III. Moisture Removing    • Remove the extra condensate if it is accumulated in the wine cabinet  at 
                    
                    ページ15に含まれる内容の要旨 
                    
                        Troubleshooting  This Troubleshooting Chart is not prepared to replace the training required for a  professional refrigeration service person, not is it comprehensive    Troubleshooting Chart  Complaint Possible Causes Response  a. Power cord unplugged a. Check for power cord plug  1.Unit not  b. No power to unit b. Check power at receptacle & fuses  running  c. Setting higher than ambient c. Lower temperature setting  temperature   d. Differential too high  d. Decrease the value as to 4 °F  e. 
                    
                    ページ16に含まれる内容の要旨 
                    
                         door opening  blinking and  b. Room too large b. Check for excessive size    beeping,  c. Ambient temperature too high c. Check for installation location  temperature  d. Exhaust restricted  d. Leave minimum 3 feet clearance for  high or not   the exhaust side and leave  cooling and   minimum 1 foot clearance for the   fresh air intake side   running  e. Malfunctioning fans e. Check for both evaporator and  continually     condenser fans   f. Improper evaporator or f. Check for air restrictions
                    
                    ページ17に含まれる内容の要旨 
                    
                         system leakage  g. Capillary tube blockage g. Check for low side pressure   a. High humidity a. Use drain line   11.Water leak  b. Air leak in wine cellar b. Check for any air leak  c. Evaporator air flow restriction c. Check air flow or air TD crossing   evaporator   d. Water passages restricted d. Clean the drip tray  e. Drip tray leak e. No water overflow but leak  a. Incorrect fuse or breaker a. Check for proper fuse or breaker  12.Circuit  b. Incorrect wirings b. Check for wirings and conn
                    
                    ページ18に含まれる内容の要旨 
                    
                        Wiring Diagram    Fig. 6.1 WIRING DIAGRAM      Fig. 6.2 CALLING FEATURE WIRING DIAGRAM                                                                      - 17 -                                                                                                                                                                                                                                                                                                                                                  
                    
                    ページ19に含まれる内容の要旨 
                    
                        Customer Support      If you still have problems, please contact us at:      Vinotemp International   17631 South Susana Road   Rancho Dominguez, CA 90221   Tel:  (310) 886-3332   Fax: (310) 886-3310   Email: info@vinotemp.com                                                                                                                        - 18 -                                                                                                                                                    
                    
                    ページ20に含まれる内容の要旨 
                    
                        Warranty       Thank you for choosing a Vinotemp cooling unit.    Please enter the complete model and serial numbers in the space provided:    Model_________________________________________________________  Serial No.______________________________________________________    Attach your purchase receipt to this owner’s manual.      1.  Limited Warranty              VINOTEMP warrants its products to be free from defects due to workmanship or  materials under normal use and service, for twelve mont