ページ1に含まれる内容の要旨 
                    
                        3E132 thru 3E134, 3E460 thru 3E462, 
  Installation, Operation, Maintenance and Parts Manual                        
5VD57 thru 5VD66, 3VH34 thru 3VH37
  
Please read and save these instructions.  This heater must be installed and serviced by trained gas installation and service 
personnel only!  Read carefully before attempting to assemble, install, operate or maintain the product described.  Protect 
yourself and others by observing all safety information.  Failure to comply with instructions 
                    
                    ページ2に含まれる内容の要旨 
                    
                        3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters 1.0 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3   Safety Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3   Applications . . . . . . . . . . . . . . . . . . . . .
                    
                    ページ3に含まれる内容の要旨 
                    
                        ! Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 1.0 Safety ! WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,  E serious injury or death. Read and understand, the installation, operating and maintenance  N instructions thoroughly before installing or servicing this equipment. Only trained, qualifi
                    
                    ページ4に含まれる内容の要旨 
                    
                        ! 3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Clearance to Combustibles ! WARNING ! CAUTION Signs shall be posted specifying the  Improperly connected gas lines may result  maximum permissible stacking height in  in serious injury and death, explosion,  E order to maintain clearances to  poisonous fumes, toxic gases,  N combustibles. asphyxiation. Connect gas lines in  G accor
                    
                    ページ5に含まれる内容の要旨 
                    
                        Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 Chart 1.1 - Clearance to Combustibles in Inches (see Figure 1.1) Model No. BTU/H Gas Type Voltage Sides Back Top Below/Front 3E132 30,000 Natural 120V 30 18 28 72 3E460 30,000 Propane 120V 30 18 28 72 5VD61 30,000 Natural 24V 30 18 28 72 E 5VD62 30,000 Propane 24V 30 18 28 72 N G 3E133 60,000 Natural 120V 3
                    
                    ページ6に含まれる内容の要旨 
                    
                        3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Standards, Certifications and Governmental Regulations The installation of this heater must comply with all applicable local, state and national specifications, regulations and  building codes (contact the local building inspector and/or fire marshall for guidance) before installing the heater system. In the absence of local codes, t
                    
                    ページ7に含まれる内容の要旨 
                    
                        Dayton Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 Figure 1.2 - Heater Dimensions DIM. “C” E N G L I S H DIM. “A” DIM. “B” SIDE VIEW FRONT/REAR Chart 1.2 - Heater Dimensions HEATER WIDTH HEATER DEPTH RAYHEAD(S) WIDTH HANGING  MODEL BTU/H DIM “A” DIM “B” DIM “C” WEIGHT ” ” 12 3/4 14 1/4 5” 18 lbs. 30,000 ” ” ” 60,000 19 1/8 15 1/4 11 1/2 27 lbs. ” ” 2
                    
                    ページ8に含まれる内容の要旨 
                    
                        3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Safety Signs and Labels It is important to provide warnings to alert individuals to  Safety warning labels must be maintained on the  potential hazards and safety actions. ANSI Z83.19a and the  infra-red heater. Illustrations of the safety labels,  National Fuel Gas Code require you to post a sign “specifying  and their locations, ar
                    
                    ページ9に含まれる内容の要旨 
                    
                        ! Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 2.0 Installation ! ! CAUTION WARNING This heater cannot be used in a building with an  Read and understand, the  uninsulated roof or condensation problems can occur. E installation, operating and  N maintenance instructions thoroughly  G before installing or servicing this  Factory recommended mounting he
                    
                    ページ10に含まれる内容の要旨 
                    
                        3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Chart 2.1 - Recommended Mounting Heights and Distances for “Total Area” Heating Mounting Heights Dim. A Distance Distance Distance Between Between Between 30º Angle 30º Angle Heaters Heater Rows Heater Parabolic  Standard  BTU/H Input Reflector (ft.) Dim. B (ft.) Dim. C (ft.) and Wall (ft.) Reflector (ft.) E 30,000 12-14 12-15 8-30 1
                    
                    ページ11に含まれる内容の要旨 
                    
                        Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 Chart 2.2 - Recommended Mounting Heights and Distances for “Spot” Heater Location E N G L I 10’ 12’ 14’ 16’ 18’ 20’ S Cold/Drafty 10’ x 10’ 100 9’ 4’ 10’ H 30,000 Average 12’ x 12’ 144 10’ 12’ 5’ 12’ BTU/H Protected/Insul. 14’ x 14’ 196 12’ 14’ 6’ 14’ Cold/Drafty 16’ x16’ 256 12’ 14’ 6’ 16’ 60,000 Average 1
                    
                    ページ12に含まれる内容の要旨 
                    
                        Dayton Dayton ! ! 3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Heater Mounting ! ! WARNING ! WARNING Failure to maintain minimum clearance  Improper suspension of the infra-red  to combustibles may result in fire and/ heater may result in collapse and being  E or explosion, property damage, serious  crushed. Always suspend from a  N injury or death. Always maintain  permanent p
                    
                    ページ13に含まれる内容の要旨 
                    
                        Dayton Dayton Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 Figure 2.4  Heater Orientation Manifold control box must  be located towards the  lower end of the heater  (towards the floor). E N G L Spark electrode must be  I in lower right corner. S H Angled at  Mount Heater Level 20˚ - 35˚ from horizontal FRONT VIEW SIDE VIEW Figure 2.5 • Gas Connection
                    
                    ページ14に含まれる内容の要旨 
                    
                        Dayton ! 3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Ventilation ! ! CAUTION WARNING Improper ventilaton may result in  Ventilate enclosed spaces and buildings  property damamge, health problems,  according to national, state, provincial  E carbon monoxide poisoning, injury or  and local codes.  Failure to provide  N death. adequate ventilation may result in  G equipment malfu
                    
                    ページ15に含まれる内容の要旨 
                    
                        ! Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 Gas Supply Important! Before connecting the gas supply to the  ! WARNING infra-red heater(s): • Check that the gas piping and service has the  capacity to handle the load of all heaters being  E installed, as well as any other gas appliances being  N connected to the supply line. G Improperly connected ga
                    
                    ページ16に含まれる内容の要旨 
                    
                        ! 3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters ! To connect the gas: This heater must be installed and serviced by trained gas  ! installation and service personnel only. WARNING Failure to install, operate or service this  The installation of this heater must conform with local  appliance in the approved manner may  building codes or, in the absence of such codes, the  E resul
                    
                    ページ17に含まれる内容の要旨 
                    
                        Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 Electrical Control systems are initiated by either 120 VAC or  ! WARNING 24 VAC.  The 120 VAC systems can be used directly  from a 120 VAC line. On 24 VAC systems, transformers  Electric Shock Hazard. must be used to supply power of sufficient VA rating for  Field wiring to the heater must be  single or mul
                    
                    ページ18に含まれる内容の要旨 
                    
                        3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters Wiring Diagrams Figure 2.9 - 24 V Schematic (5VD57 thru 5VD66) • Direct Spark     Ignition E N • VA Draw: 12 G L • Amps: .48 I • Potted Circuit  S Board H (sold separately) Figure 2.10 - 120 V Schematic (3E132 thru 3E134, 3E460 thru 3E462, 3VH34 thru 3VH37) • Direct Spark    Ignition • VA Draw: 12 • Amps: .10 • Potted Circuit  Board 
                    
                    ページ19に含まれる内容の要旨 
                    
                        ! Dayton Installation, Operation, Maintenance and Parts Manual                                                     Models 3E132 thru 3E134, 3E460 thru 3E462,  5VD57 thru 5VD66, 3VH34 thru 3VH37 3.0 Operation Upon satisfactory completion of the electrical supply  ! WARNING and purging of the gas supply line to the heater(s),  follow the lighting instructions on the heater’s rating  Do not atempt to ignite heater by hand.   label to put the heater into operation. Failure to comply could result in 
                    
                    ページ20に含まれる内容の要旨 
                    
                        ! 3E132 thru 3E134, 3E460 thru 3E462,  Dayton Installation, Operation, Maintenance and Parts Manual 5VD57 thru 5VD66, 3VH34 thru 3VH37 ® Dayton High Intensity Heaters 4.0 Maintenance ! WARNING It is recommended that the following become a  standard yearly procedure to obtain maximum operating  Use protective glasses when cleaning  efficiency and trouble free operation. the heater. E During long periods of non-usage, remove or cover  N heater with a polyethylene bag and shut off gas supply.  G Di