ページ1に含まれる内容の要旨 
                    
                        VENTED DECORATIVE GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
MODELS BQMV18N, BQMV18P, 
BQMV24N AND BQMV24P
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable 
vapors and liquids in the vicinity of this or any other 
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switc
                    
                    ページ2に含まれる内容の要旨 
                    
                        WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation  and operational procedures. For assistance or addi- tional information consult a qualified installer, service  agency or the gas supplier. WARNING: This appliance is for installation only in  a solid-fuel burning masonry or UL127 factory-built  fireplace, constructed of noncombustible material and  connected to a working flue. (See pa
                    
                    ページ3に含まれる内容の要旨 
                    
                        SAFETY INFORMATION  WARNING: Do not use a blow- er insert, heat exchanger insert or   WARNING: This product con- other accessory not approved for  tains and/or generates chemicals  use with this appliance. known to the State of California  to cause cancer or birth defects   WARNING: This appliance  or other reproductive harm. is equipped for (natural or pro- pane/LP) gas. Field conversion   WARNING: Keep flue open  is not permitted. when operating unit.  WARNING: Do not allow fans  IMPORTANT: Rea
                    
                    ページ4に含まれる内容の要旨 
                    
                        9. Do not use a blower insert, heat exchanger  SAFETY INFORMATION insert or other accessory not approved for use  Continued with this log set. 10. The installation and provisions for combustion  Keep the appliance area clear  and ventilation air must conform with the Na- and free from combustible ma- tional Fuel Gas Codes, ANSI Z233.1/NFPA 54,  terials, gasoline and other flam- Section 5.3, Air for combustion and Ventilation. mable vapors and liquids. 11. Do not run heater • where flammable liquid
                    
                    ページ5に含まれる内容の要旨 
                    
                        PRODUCT INSTALLATION IDENTIFICATION  WARNING: A qualified ser- vice person must install heater.   WARNING: Failure to posi- Follow all local codes. tion the parts in accordance  with these diagrams or failure   WARNING: Before installing  to use only parts specifically  in a solid fuel burning fireplace,  approved with this appliance  the chimney flue and firebox  may result in property damage  must be cleaned of soot, creo- or personal injury. sote, ashes and loose paint by a  qualified chimney clean
                    
                    ページ6に含まれる内容の要旨 
                    
                        drawing it up the chimney. If the smoke spills out  INSTALLATION into the room, extinguish the flame and remove any  Continued  obstruction until proper venting is achieved. CHECK GAS TYPE The chimney flue damper must be fixed open to pro- Use the correct gas type (natural or propane/LP) for  vide a minimum of 32 square inch of free air opening  your unit. If your gas supply is not correct, do not  at all times during operation of the log set. A damper  instal in fireplace. Call dealer where you bou
                    
                    ページ7に含まれる内容の要旨 
                    
                        INSTALLATION  CAUTION: Never connect  Continued  propane/LP unit directly to the  INSTALLING APPLIANCE propane/LP supply. This unit re- quires an external regulator (not   WARNING: Special care is  supplied). Install the external  required if you are installing the  regulator between the unit and  unit into a sunken fireplace. You  the propane/LP supply. must raise the fireplace floor to  allow access to gas log controls.  This will insure adequate air  WARNING: Never connect  flow and guard against
                    
                    ページ8に含まれる内容の要旨 
                    
                        Locate sediment trap where trapped matter is not  INSTALLATION likely to freeze. A sediment trap traps moisture and  Continued  contaminants. This keeps them from going into  heater controls. If sediment trap is not installed or   CAUTION: Use only new, black  is installed wrong, heater may not run properly. iron or steel pipe. Internally-tinned  copper tubing may be used in   CAUTION: Avoid damage to  certain areas. Check your local  gas control. Hold gas control  codes. Use pipe of 1/2" diamet
                    
                    ページ9に含まれる内容の要旨 
                    
                        Pressure Testing Appliance Gas  INSTALLATION Connections Continued  1. Open equipment shutoff valve (see Figure 8). 6. Reconnect heater and equipment shutoff  2. Open main gas valve located on or near gas  valve to gas supply. Check reconnected fit- meter for natural gas or open propane/LP  tings for leaks.  supply tank valve. Test Pressures Equal To or Less Than 3. Make sure control knob of appliance is in the  1/2 PSIG (3.5 kPa) OFF position. 1. Close equipment shutoff valve (see Figure 8). eck
                    
                    ページ10に含まれる内容の要旨 
                    
                        5. Wait five (5) minutes to clear out any gas.  OPERATING APPLIANCE If you then smell gas, STOP! Follow "B" in  FOR YOUR SAFETY  the safety information in column 1. If you  READ BEFORE LIGHTING don't smell gas, go on the next step. 6. Press in and turn control knob counter- clockwise  to the PILOT position.   WARNING: Keep flue open  Press in control knob for five (5) seconds  when operating unit. (see Figure 12).  7. With control knob pressed in, press and release   WARNING: If you do not fol- ign
                    
                    ページ11に含まれる内容の要旨 
                    
                        To Unlock press both buttons tog ether on hand- OPERATING APPLIANCE held remote control until the light stops flashing.  Continued The hand-held remote is now unlocked. NOTICE: You must light the pilot  INSPECTING BURNERS before using the hand-held re- Check pilot flame pattern and burner flame pat- mote control unit. See Lighting terns often. Instructions on page 10. PILOT FLAME PATTERN You can view the pilot light through the pilot  After lighting, let pilot flame burn for about  viewing hole on t
                    
                    ページ12に含まれる内容の要旨 
                    
                        • Keep area around log set clean and clear of  INSPECTING BURNERS debris. Continued • Periodically inspect the air mixer and burner  If burner flame pattern is incorrect, as shown in  tube for foreign matter blocking the air inlet  Figure 18. and flame holes. • turn appliance off (see To Turn Off Gas to Ap- • Once every year a qualified agency or certified  pliance, page 10) chimney sweep should examine and clean the  • see Troubleshooting, page 13 venting system of the fireplace. Dark Orange  SERVIC
                    
                    ページ13に含まれる内容の要旨 
                    
                        TROUBLESHOOTING  WARNING: Turn off appliance and let cool before servicing. Only  a qualified service person should service and repair heater.  CAUTION: Never use a wire, needle or similar object to clean  ODS/pilot. This can damage ODS pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, 1. Ignitor electrode not con- 1. Reconnect ignitor cable there is no spark at ODS/pilot nected to ignitor cable 2. 
                    
                    ページ14に含まれる内容の要旨 
                    
                        TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS/pilot lights but flame goes 1. Control knob not fully 1. Press in control knob fully out when control knob is re- pressed in leased 2. Control knob not pressed in 2. After ODS/pilot lights, keep  long enough control knob pressed in for 30  seconds 3. Safety interlock system has 3. Wait one minute for safety in- been triggered terlock system to reset. Repeat  ignition operation 4. Equipment shutoff valve not 4. Fully open equipme
                    
                    ページ15に含まれる内容の要旨 
                    
                        TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Dark orange flame in burner dur- 1. Not enough air 1. Check burner(s) for dirt  ing burner combustion and debris. If found, clean  burner(s) (see Cleaning and  Maintenance, page 12) 2. Gas regulator defective 2. Replace gas regulator Slight smoke or odor during initial 1. Residues from manufacturing 1. Problem will stop after a few  operation processes and log curing hours of operation Produces a whistling noise when 1. Turning cont
                    
                    ページ16に含まれる内容の要旨 
                    
                        TROUBLESHOOTING Continued  WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your  building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating appliance where impurities in air exist may create odors. Cleaning supplies,  paint, paint remover, cigarette smoke, c
                    
                    ページ17に含まれる内容の要旨 
                    
                        SPECIFICATIONS This appliance has been design certified to ANSI ZZ1.60-2003 and CSA 2.26-2003 Decorative Gas  Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.     BQMV18N BQMV18P BQMV24N BQMV24P Btu (Variable) 36,000/53,000 35,000/45,000 36,000/53,000 35,000/45,000  Type Gas Natural Gas Only Propane/LP Only  Natural Gas Only Propane/LP Only Ignition Piezo Piezo Piezo Piezo Manifold Pressure 3.5" W.C. 10" W.C.  3.5" W.C. 10" W.C.  Inlet Gas Pressure (in. of w
                    
                    ページ18に含まれる内容の要旨 
                    
                        ILLUSTRATED PARTS BREAKDOWN MODELS BQMV24N, BQMV24P, BQMV18N AND BQMV18P 17 16 15 7 1 9 8 6 13 5 10 3 14 12 2 4 1 1 18 www.desatech.com 117423-01A                                                                                                                                                                                                                                                                                                                                                                  
                    
                    ページ19に含まれる内容の要旨 
                    
                        PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions  listed under Replacement Parts on page 12 of this manual. KEY PART NUMBER NO. BQMV24N BQMV24P BQMV18N BQMV18P DESCRIPTION QTY. 1 111793-01 111793-01 111808-02 111808-02 Grate 1 2 111817-02 111817-02 111817-02 111817-02 Flexible Tube 1 3 099998-01 099998-01 099998-01 099998-01 Fan Switch 1 4 103784-02 103784-02 103784-02 103784-02 Knob Extension (HI/LOW) 1 5 103784-01 103784-01 10378
                    
                    ページ20に含まれる内容の要旨 
                    
                        WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our  standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY  VENTED GAS LOG APPLIANCES DESA warrants this product to be free from defects in materials and components for four (4) years from the date  of