ページ1に含まれる内容の要旨 
                    
                        MODEL 2400E NG and 2400E LP - INDOOR MODEL
Temperature Modulated with Electronic Ignition
Suitable for heating potable water only
Not approved for space heating purposes
(Intended for variable flow applications)
2400 E NG - Natural Gas
2400 E LP - Liquefied Petroleum (LP) Gas
Warning: If the information in this manual is not What to do if you smell gas
followed exactly, a fire or explosion may result
• Close gas valve. Open windows.
causing property damage, personal injury or death.
• Do not try
                    
                    ページ2に含まれる内容の要旨 
                    
                        Index Index 1 Warning 1Warning 2 Warning: If the information in this 2 Appliance details 4 manual is not followed exactly, a fire or 2.1Features 4 explosion may result causing property 2.2 2400 E Specifications (Technical data) 4 damage, personal injury or death. 2.3 Dimensions and Minimum installation clearances 6 2.4 General rules to follow for safe operation 7 2.5 Proper location for installing your heater 7 Warning: Improper installation, 2.6Clearances 8 2.7 Mounting installation 8 adjustmen
                    
                    ページ3に含まれる内容の要旨 
                    
                        
                    
                    ページ4に含まれる内容の要旨 
                    
                        Appliance details 2 Appliance details 2.1 Features 2.2 2400 E Specifications (Technical  data) Parts Approved in US/Canada • Touch Pad interface control • High power pre-mix compact burner with low Nox Capacity emissions Maximum flow rate: 6.35 GPM (24 l/min) at a 45°F • Modulating Gas Valve with constant gas:air ratio (25°C) rise. control  Maximum output • Modulating water valve for improved comfort and 142,968 Btu/h (41.8 kW) temperature control. Safety Maximum input 175,000 Btu/h (51.2 kW) • 
                    
                    ページ5に含まれる内容の要旨 
                    
                        Appliance details Combustion Do not lose this manual. Please complete and return the enclosed product registration card. •NOx ≤ 55 ppm Before installing the unit, be certain you have the •CO ≤ 250 ppm correct heater for your type of Gas - Propane or •CO level set from factory, see chapter 9. 2 Natural Gas. Identification labels are found on the shipping box, and on the rating plate which is located on Dimensions the right side panel of the cover. • Depth (in): 8 ½” (220 mm) To remove front cover
                    
                    ページ6に含まれる内容の要旨 
                    
                        Appliance details 2.3 Dimensions and Minimum installation clearances Fig. 4 Dimensions 1 Cover 2 On/Off switch 3 Reset button 4 LCD display 5 Program button 6 Temperature buttons Fig. 5 Minimum clearances Model 2400 E TOP (A) 12” FRONT (B) 1” BACK 0” SIDES 1” FLOOR (C) 12” VENT DIAMETER 3” Table 1 Minimum clearances 6 6 720 608 263                                                                                                                                                                       
                    
                    ページ7に含まれる内容の要旨 
                    
                        Appliance details 2.4 General rules to follow for safe 2.5 Proper location for installing your operation heater B 1. You should follow these instructions when you Carefully select the location of the water heater. For install your heater. In the United States: The your safety and for proper heater operation, you must installation must conform with local codes or, in the provide combustion air to the heater and a proper absence of local codes, the National Fuel Gas Code exhaust vent system. ANSI 
                    
                    ページ8に含まれる内容の要旨 
                    
                        Appliance details 2.6 Clearances The 2400 E is design certified for installation on a combustible wall (see2.7 Mounting installation) provided the floor covering below the heater is noncombustible. For installations in an alcove or closet, maintain the minimum clearances to combustible and non-combustible materials listed below. See also Fig. 5. A. Top 12 inches (306 mm) B. Front 1 inches (25 mm) C. Back 0 inches D. Sides 1 inches (25 mm) E. Bottom 12 inches (306 mm) Clearances from any exhaust 
                    
                    ページ9に含まれる内容の要旨 
                    
                        Appliance details construction, infiltration air is normally adequate to 2.9 Venting  provide air for combustion. Warning: Do not reduce the vent • Appliances located in confined spaces: (exhaust and combustion) pipe sizes The confined space must be provided with two and do not common vent with any other permanent openings, one commencing within 12 vented appliance or stove. inches (304.8mm) of the top and one commencing within 12 inches (304.8mm) of the bottom of the NOTE: This appliance's exha
                    
                    ページ10に含まれる内容の要旨 
                    
                        Appliance details The maximum flue gas exhaust temperature on the 2400 E is 437°F (225°C) Venting Exhaust * Exhaust * Exhaust Combustion Combustion Vent pipe Vent pipe  Options vent vent vent air pipe air pipe clearances clearances  diameter maximum minimum diameter maximum within an within an  and length length and material length unenclosed enclosed  material space space + Room 3 or 4 26 feet (8 3 feet 3 inch PVC, 26 feet (8 ** See vent ** See vent  sealed                 inch m) with one alum
                    
                    ページ11に含まれる内容の要旨 
                    
                        
                    
                    ページ12に含まれる内容の要旨 
                    
                        Appliance details 2.9.1 Venting options Open combustion installation (SINGLE PIPE SYSTEM) Installing this water heater as a room sealed (TWIN PIPE SYSTEM) is the recommended method. Contact Not recommended in cold climate areas, see BBTNA or dealer for available vent termination kits and Chapter 2.8. vent materials for this water heater. Exhaust venting shall be done with 3" or 4" stainless steel (AL29-4C) vent pipe. i Room sealed installation (TWIN PIPE SYSTEM) Fig. 14 Exhaust vent pipe: ≤ 26 f
                    
                    ページ13に含まれる内容の要旨 
                    
                        Appliance details Recommended exhaust vent terminator position Fig. 16 Ref. Description Minimum distance Directly below an opening; operable windows, doors and any non- A 36 in mechanical fresh air openings Below a gutter, sanitary pipework or eaves 24 in B Below a gutter, sanitary pipework or eaves, protected by metal  12 in shielding C From any internal corner 12 in Above ground 12 in D* Above a paved sidewalk 7 ft From an opposing wall or structure facing the termination 24 in E From any othe
                    
                    ページ14に含まれる内容の要旨 
                    
                        
                    
                    ページ15に含まれる内容の要旨 
                    
                        
                    
                    ページ16に含まれる内容の要旨 
                    
                        Appliance details FOR NATURAL GAS Maximum Capacity of pipe in Cubic Feet of Gas per Hour for Gas Pressure of 0.5 Psig or less and a Pressure drop of 0.3 in Water Column (0.75mbar).(Based on a 0.60 Specific Gravity Gas) Btu numbers given in thousands. Follow boxed numbers for piping just one 2400 E (example: ¾” B.I. Natural Gas pipe for 20 ft (6.1m). will handle 190,000 btu’s (55.7 kWh). For multiple appliances combine the total btu input load and then refer to applicable chart below. Nominal Iro
                    
                    ページ17に含まれる内容の要旨 
                    
                        
                    
                    ページ18に含まれる内容の要旨 
                    
                        
                    
                    ページ19に含まれる内容の要旨 
                    
                        Appliance details 2.14 Electrical connections 2.16 For your safety read before operating your water heater Warning: For safety reasons, disconnect the power supply to the Warning: If you do not follow these heater before any service or testing is instructions exactly, a fire or explosion performed. may result causing property damage, personal injury or loss of life. Warning: This heater must be A. This appliance is equipped with electronic ignition for electrically grounded in accordance lightin
                    
                    ページ20に含まれる内容の要旨 
                    
                        Appliance details NOTE: on a first time initial instal- lation or after gas line work has  i been done, existence of air in the  gas line will cause ignition delay  when the hot water is turned on.   This will result in an error (EA) on  the units display screen. This is  normal. When this occurs, leave  the hot water running and wait 3-5  seconds, then reset the unit (Fig.  26, pos. 2).  Wait for (EA) to disap- pear.  The heater will begin to at- tempt ignition again, if the (EA)  reappears the