UNVENTED (VENT-FREE) UNIVERSAL FIREBOX
OWNER’S OPERATION AND INSTALLATION MANUAL
PFS
®
US
CIRCULATINg MODELS
CFB g 32CC
 WARNING: If the information in this manual is not 
followed exactly, a fire or explosion may result causing 
property damage, personal injury or loss of life.
FoR use oNly WIth A lIsted GAs-FIRed uNveNted 
decoRA tIve Room heA teR Not to exceed 40,000 
Btu/Hr. Do not BuilD a wooD fire.
Carefully review the instructions supplied
                    
                    ページ2に含まれる内容の要旨 
                    
                        TABLE OF CONTENTS Safety .................................................................. 2 Installation ........................................................... 8 Local Codes......................................................... 3 Replacement Parts ............................................ 16 Product Features ................................................. 4 Technical Service............................................... 16 Locating Firebox ........................................
                    
                    ページ3に含まれる内容の要旨 
                    
                        SAFETy Continued 1. Do not use this firebox as a wood-burning  f irebox front and screen become  fireplace. Use only decorative unvented  very hot when running heater.  room heaters (log sets). Keep children and adults away  2. Do not add extra logs or ornaments such  from hot surface to avoid burns  as pine cones, vermiculite or rock wool.  Using these added items can cause  or clothing ignition. f irebox  sooting. will remain hot for a time after  3. Use only the provided hood or appropri- shu
                    
                    ページ4に含まれる内容の要旨 
                    
                        PRODUCT FEATURES opeRA tIoN ReFRActoR y bRIck lINeR  This firebox is designed for use with approved Your firebox may feature a concrete refrac- ANSI Z21.11.2 decorative type unvented room tory brick liner. As with all concrete liners,  heaters. (Physical size limitations apply. Refer this liner may develop slight cracks when  to minimum firebox requirements supplied exposed to heat. These cracks will not affect  with log heater.) It requires no outside vent- the performance of the fireplace or v
                    
                    ページ5に含まれる内容の要旨 
                    
                        PRODUCT SPECIFICATIONS 32" models Left Side View  with Air Kit  Outside Air  Kit Location  (Optional) 1 22 /2" 4" 1 8 / " 8 Firebox Top View  1 10 /2" 1 8 /8" 9 2 /16" 5/8" 7 3 /16" 1 15 25 /8" 8 /16" 1 29 /2" 7 34 /16" 1 3 19 /2" 36 /8" 11 16 /16" 13 2 / " 16 1 12 /4" Standoffs 1 4 /4" 5 8 /8" 1 36 /2" 1 Built-In 3 /2" Side 1 Nailing 32 /4" Flanges 7 18 /16" 15 3 14 /16" 16 /4" 9 1 1 / " 29 /2" 16 Square Gas Line 3 3 /8" 1 Access 8 /8" Holes 9 5 2 /16" 6 / " 16 1 2 /4" Electrical 6" 15 8 / " Fr
                    
                    ページ6に含まれる内容の要旨 
                    
                        AIR FOR COMBUSTION AND VENTILATION unusually t ight Construction  WARNING: this heater shall  The air that leaks around doors and windows  not be installed in a room or may provide enough fresh air for combustion  and ventilation. However, in buildings of un- space unless the required vol- usually tight construction, you must provide  ume of indoor combustion air  additional fresh air. is provided by the method de- unusually tight construction is defined as  scribed in the National Fuel Gas  con
                    
                    ページ7に含まれる内容の要旨 
                    
                        AIR FOR COMBUSTION AND VENTILATION Continued 4. Compare the maximum Btu/Hr the space  deteRmINING FResh-AIR FloW  can support with the actual amount of Btu/ FoR heA teR locA tIoN Hr used. Determining if You Have a Confined or    _________ Btu/Hr (maximum the space  unconfined space can support)  Use this work sheet to determine if you have    _________ Btu/Hr (actual amount of  a confined or unconfined space.   Btu/Hr used) space: Includes the room in which you will   Example: 63,360 Btu/Hr (max
                    
                    ページ8に含まれる内容の要旨 
                    
                        AIR FOR COMBUSTION AND VENTILATION Continued ventilation Air From outdoors veNtIlA tIoN AIR Provide extra fresh air by using ventilation  Ventilation air from inside Building  grills or ducts. You must provide two perma- This fresh air would come from an adjoining  nent openings: one within 12" of the ceiling  unconfined space. When ventilating to an  and one within 12" of the floor. Connect these  adjoining unconfined space, you must provide  items directly to the outdoors or spaces open  two p
                    
                    ページ9に含まれる内容の要旨 
                    
                        INSTALLATION Continued IMPORTANT: Vent-free gas log heaters add optional cabinet mantels (see Accessories,  moisture to the air. Although this is beneficial, page 17) or as a built-in unit. Clearances are the  installing firebox in rooms without enough same for either installation method.  ventilation air may cause mildew to form from  too much moisture. See Air for Combustion  c Aut Io N: do not install  and Ventilation, page 6.  the firebox directly on carpet  IMPORTANT: Make sure firebox is l
                    
                    ページ10に含まれる内容の要旨 
                    
                        INSTALLATION Continued t able 1 Not Ice : If your installation does  rough opening Dimensions for  not meet the minimum clear- built-in Installation ances shown, you must do one  Front Width Depth Model (Inside to Inside) Height (Min.) of the following: 7 3 1 32" 34 /8" 36 /4" 16 / " 4 • raise the mantel to an accept- able height • remove the mantel buIlt-IN FIRebox INst AllA tIoN Figure  Depth Built-in installation of this firebox involves  (Minimum) 6a installing firebox into a framed-in enclo
                    
                    ページ11に含まれる内容の要旨 
                    
                        INSTALLATION Continued 6. If using an optional perimeter trim kit, INst AllING FIRebox usING  install the trim after final finishing and/or  optIoNAl AccessoR y mANtels painting of wall. See instructions included  with trim accessory for attaching trim.  warninG: a qualified ser- 7. Install and properly test gas log heater.  vice person must install firebox.  Follow installation instructions included  follow all local codes. with the vent-free gas log heater that is  being installed. This firebo
                    
                    ページ12に含まれる内容の要旨 
                    
                        INSTALLATION Continued Locate the recessed knockout in one of the  NotIce: if a log set is installed  firebrick sidewall liners (see Figure 8 on page  in the firebox, disconnect log  11 and Figure 9). Firmly tap the center of the  set from gas supply and remove  knockout with a chisel until it is released.  from firebox. Contact a qualified  Carefully chisel the rough edges of the hole  service person to do this. you have made to smooth edges. This hole  will line up with the hole in the outer c
                    
                    ページ13に含まれる内容の要旨 
                    
                        INSTALLATION Continued  model bk Installation cure speed control to bracket with lock nut  1. Attach the power cord to blower motor by by pushing and turning lock nut with pliers  firmly pushing two female terminals at end clockwise until it is tight against bracket. of power cord onto two spade terminals  7. Remove knockout plug from louver panel  on blower motor (see Figure 11). by pressing top and bottom retaining  2. Attach green ground wire from power cord clips. to blower housing using scr
                    
                    ページ14に含まれる内容の要旨 
                    
                        INSTALLATION Continued  12. Turn on power to duplex outlet if previ- Screws ously turned off per warning in column 2,  page 12. 13. Plug in blower power cord to duplex outlet  (see Figure 10, page 12). 14. Turn blower on and check for operation.  Turn blower off by turning knob fully coun- terclockwise before continuing.  15. Peel off backing paper and stick supplied  wiring diagram decal on firebox bottom  approximately 12" in from of blower (see  Leg  BK3 Blower Figure 13). Stands Figure 14 - 
                    
                    ページ15に含まれる内容の要旨 
                    
                        INSTALLATION Continued  9. Plug in blower power cord to duplex outlet  (see Figure 10, page 12). 10. Using ON/OFF rocker switch to turn  blower on and check for operation. Turn  blower off before continuing.  Duplex Box/ 11. Peel off backing paper and stick supplied  Handy Box wiring diagram decal on firebox bottom  approximately 12" in from of blower (see  Figure 16). Strain Relief 12. Replace all panels and/or brick bottom  Figure 17 - Hard-Wiring Firebox panel if previously removed. ON/OFF co
                    
                    ページ16に含まれる内容の要旨 
                    
                        INSTALLATION Continued  Top View of Rod Layout  INst AllING FIReplAce hood  ANd scReeN 1. Attach hood to firebox using screws pro- Rear Hole vided (see Figure 19). 2. Insert each rod through all rings located Identification  Front  Label Location at top of screen. Hole  3. Insert first rod into rear hole in left side  of firebox. Fasten rod to rear hole near  center of firebox using #10 x 3/8" Phillips  screw provided (see Figure 20). Rod  Ring 4. Insert other rod into front hole on right  side 
                    
                    ページ17に含まれる内容の要旨 
                    
                        ACCESSORIES Purchase these accessories from your local l ouve R tRI m  dealer. If they can not supply these accessories  For use with Rolled louvers only call FMI PRODUCTS, LLC at 1-866-328-4537  lt32 - 32" Brushed Brass b for information. You can also write to the ad- lt32p - 32" Platinum dress listed on the back page of this manual. lo b WeR kIt peRImeteR tRIm bk - Squirrel Cage Blower With Speed  pt32b - 32" Brushed Brass Control pt32 - 32" Platinum p bk3 - Triple Fan Blower System FAce/louve
                    
                    ページ18に含まれる内容の要旨 
                    
                        PARTS models cGFb32cc 22  21  20  23  18  19  17  16  28  15  29  10  25  9  7  26  5  24  27  4  11  14  3  12  6  13  2  8  1  18 www.fmiproducts.com 124970-01B                                                                                                                                                                                                                                                                                                                                                  
                    
                    ページ19に含まれる内容の要旨 
                    
                        PARTS This list contains replaceable parts used in your firebox. When ordering parts, follow the  instructions listed under Replacement Parts on page 17 of this manual. Part number key  no. cGFb32cc descRIptIoN qtY. 1 108441-01 Screen 1 2 108700-01 Screen Rod 2 3 11418 Push-On Nut 2 4 108414-01 Deflector Hood 1 5 108423-02 Face Top Panel 1 6 108423-05 Face Bottom Panel 1 7 ** Face Weldment 2 8 ** Firebox Support Leg 2 9 108434-02 Left Refractory Red 1 10 108430-02 Rear Refractory Red 1 11 108432
                    
                    ページ20に含まれる内容の要旨 
                    
                        WARRANTy KEEP ThIS WARRANTy Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased  __________________________ Keep receipt for warranty verification. FMI PRODUCTS, LLC LIMITED WARRANTIES New roducts p standard Warranty: FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free  from defects in material and workmanship for a period of  two (2) years from the