ページ1に含まれる内容の要旨 
                    
                        DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
6000G
6000G-LP
6000G-IPI
6000G-IPILP
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with 
and maintenance these instructions for safe 
party responsible for use 
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these 
HOT SURFACES! 
instructions is not followed exactly, a fi re 
Glass and other surfaces are hot during 
                    
                    ページ2に含まれる内容の要旨 
                    
                        Read this manual before installing or operating this appliance.  Please retain this owner’s manual for future reference. This owner’s manual should be retained for future  A. Congratulations reference. We suggest that you keep it with your other  Congratulations on selecting a Heat & Glo gas fi replace, an  important documents and product manuals. elegant and clean alternative to wood burning fi replaces.  The information contained in this owner’s manual, unless  The Heat & Glo gas fi replace you h
                    
                    ページ3に含まれる内容の要旨 
                    
                            Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
                    
                    ページ4に含まれる内容の要旨 
                    
                        13 Finishing   A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 52 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 C. Doors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 14 Appliance Setup   A. Remove Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . 54 B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 54 C. Clean the Appliance . . . . . . . . . . . . . . . .
                    
                    ページ5に含まれる内容の要旨 
                    
                        B. Limited Lifetime Warranty Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet  and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada.   Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.  Warranty Period HHT Manufactured Appliances and Venting Components Covered
                    
                    ページ6に含まれる内容の要旨 
                    
                        B. Limited Lifetime Warranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass  gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials.  Rust and/or corrosion  on any of the metal surfaces, cast iron components, baffl es, fi repots, doors, or fi rebox area are not covered by this  warranty. • Noise resulting from minor expansion, contraction, or movement of certain p
                    
                    ページ7に含まれる内容の要旨 
                    
                        Listing and Code Approvals   1 1  A. Appliance Certifi cation C. BTU Specifi cations Maximum Minimum Orifi ce Models Input Input Size  MODELS: 6000G, 6000G-IPI (U.S. or Canada) BTU/h BTU/h (DMS) LABORATORY: Underwriters Laboratories, Inc. (UL) US 30,000 18,200 37 (0-2000 FT) 6000G (NG) TYPE: Direct Vent Gas Appliance Heater CANADA 6000G-IPI (NG) STANDARD: ANSI Z21.88-2000 • CSA2.33-M98 • UL307B 27,000 16,380 38 (2000-4500 FT) US 30,000 18,200 52 This product is listed to ANSI standards for “Vented 
                    
                    ページ8に含まれる内容の要旨 
                    
                        Inspection Note: The following requirements reference various  The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this  tally vented gas fueled equipment shall not approve the  document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed  H. Requirements for the Commonwealth of  in accordance with the provisions of 248 CMR 5.08(2)(a)1  Massachusetts through 4.  For all side wall 
                    
                    ページ9に含まれる内容の要旨 
                    
                        User Guide Operating Instructions   2 2  • Keep remote controls out of reach of children. A. Gas Fireplace Safety • Never leave children alone near a hot fi replace, whether  operating or cooling down. WARNING • Teach children to NEVER touch the fi replace. HOT SURFACES!  Glass and other surfaces are hot during  • Consider not using the fi replace when children will be  operation AND cool down. present. Hot glass will cause burns. Contact your dealer for more information, or visit: www. • DO NOT to
                    
                    ページ10に含まれる内容の要旨 
                    
                        CLEAR SPACE  3 FT. IN FRONT OF FIREPLACE C. Fan Kit (optional) F. Fixed Glass Assembly If desired, a fan kit may be added.  Contact your dealer to See Section 14.G. order the correct fan kit. G. Remote Controls, Wall Controls and Wall  D. Clear Space Switches WARNING! DO NOT place combustible objects in front  Follow the instructions supplied with the control installed  of the fi replace or block louvers. High temperatures may  to operate your fi replace: start a fi re. See Figure 2.2. For safety: 
                    
                    ページ11に含まれる内容の要旨 
                    
                        I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries.  When using batteries, unplug the transformer. To prolong battery  life, remove them when using the transformer. FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) WARNING: If you do not follow these instructions exactly, a fi re or explosion  may result causing property damage, personal injury or loss of life. 1. Turn off all electric power to the appliance. •  Immediately call your gas supplie
                    
                    ページ12に含まれる内容の要旨 
                    
                        J. Lighting Instructions (Standing Pilot) LIGHTING FOR YOUR SAFETY INSTRUCTIONS READ BEFORE LIGHTING 1. Open control access panel. WARNING: If you do not follow these instructions exactly, a fi re or explosion  2. Turn off all electric power to  may result causing property damage, personal injury or loss of life. the appliance. 3. Push in gas control knob  A. This appliance has a pilot which •   If you cannot reach your gas sup- slightly and turn clockwise  plier, call the fi re department. must b
                    
                    ページ13に含まれる内容の要旨 
                    
                        K. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours  continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.G. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously  on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi re- place break-in. •
                    
                    ページ14に含まれる内容の要旨 
                    
                        Maintenance and Service   3 3   Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be  replaced prior to operating the fi replace. Frequency: Annually By:  Homeowner When properly maintained, your fi replace will give you  many years of trouble-free service.  We recommend an- Tools needed:  Protective gloves, stable work surface nual service by a qualifi ed service technician.  • Assess condition of screen and replace as necessary.   A. Maintenance Tasks-Homeowner • Insp
                    
                    ページ15に含まれる内容の要旨 
                    
                        • Replace fi replace if fi rebox has been perforated.  Venting Frequency: Seasonally Control Compartment and Firebox Top By:  Homeowner Frequency: Annually Tools needed:  Protective gloves and safety glasses. By:  Qualifi ed Service Technician • Inspect venting and termination cap for blockage or  Tools needed: Protective gloves, vacuum cleaner, dust  obstruction such plants, bird nests, leaves, snow, debris,  cloths etc. • Vacuum and wipe out dust, cobwebs, debris or pet hair.   • Verify terminati
                    
                    ページ16に含まれる内容の要旨 
                    
                        (Either cobrahead or SIT) Figure 3.1  IPI Pilot Flame Patterns Figure 3.2  Standing Pilot Flame Patterns 16 Heat & Glo  •  6000G, 6000G-IPI  •  2103-900  Rev. O  •  12/08 PRODUCT SPECIFIC                                                                                                                                                                                                                                                                                                                         
                    
                    ページ17に含まれる内容の要旨 
                    
                        Installer Guide Getting Started   4 4  A. Typical Appliance System NOTICE:  Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not  drawn to scale. Actual product may vary from pictures in manual HORIZONTAL  TERMINATION CAP  Note: Dual venting configurations  (SECTION 10.M ) ARE NOT allowed. Appliance MUST  be vented EITHER vertically OR  horizontally. VERTICAL TERMINATION CAP  (SECTION 10.J) NON-COMBUSTIBLE ROOF FLASHING  MAINTAIN
                    
                    ページ18に含まれる内容の要旨 
                    
                        B. Design and Installation Considerations D. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to • Carefully remove the appliance and components from  operate with all combustion air siphoned from outside of the packaging.  the building and all exhaust gases expelled to the outside.  • The vent system components and decorative doors and  No additional outside air source is required. fronts may be shipped in separate packages.  Installation MUST comply with loca
                    
                    ページ19に含まれる内容の要旨 
                    
                        Framing and Clearances   5 5   NOTICE: Illustrations refl ect typical installations and are  A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams  When selecting a location for the appliance it is important to  are not drawn to scale. Actual installation may vary due to  consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate  clearance around air openings and for service access.  Due to
                    
                    ページ20に含まれる内容の要旨 
                    
                        To further prevent drafts, the wall shield and ceiling fi re- B. Constructing the Appliance Chase stops should be caulked with high temperature caulk to  A chase is a vertical box-like structure built to enclose the  seal gaps. Gas line holes and other openings should be  gas appliance and/or its vent system. In cooler climates  caulked with high temperature caulk or stuffed with un- the vent should be enclosed inside the chase. faced insulation. If the appliance is being installed on a  NOTICE: